background image

2

Description (continued)

4

500

LAMP POWER

MUST BE TAKEN TO INSURE THAT PERSONNEL ARE

WHICH IS HARMFUL TO EYES AND SKIN. GREAT CARE

ULTRAVIOLET IRRADIATORS EMIT RADIATION

CAUTION

ON

LAMP

ON

POWER

POWER

LAMP

OFF

ON

OFF

ON

0

INTENSITY

LAMP

LOW

HIGH

3000

2500

1500

1000

2000

BEFORE CLEANING OR RELAMPING, ALWAYS TURN

OR LAMP SHIELDING PROVIDED WHEN LAMP IS IN USE.

SUITABLE EYE AND SKIN PROTECTION MUST BE WORN

NOT EXPOSED TO DIRECT OR REFLECTED RADIATION.

THE POWER OFF.

P/N 980160

LOCTITE IS A TRADEMARK OF LOCTITE CORPORATION, U.S.A.

Mexico 01-800-8499-412

Canada 1-800-263-5043

U.S.A. 1-800-LOC-TITE

For Equipment Parts or Service:

LB-10322A

15.851"

15.00"

14.688"

14.19"

1.56"

12.13"

10.25"

.58"

.31"

Figure 1 Power Supply

Содержание 980160

Страница 1: ...EQUIPMENT O P E R A T I O N M A N U A L Loctite High Intensity Ultraviolet Source 980160 ...

Страница 2: ...eration 3 2 3 Operating Elements and Controls 5 3 Installation 5 3 1 Utility and Space Requirements 6 3 2 Initial Set Up 6 3 3 Additional Cooling 6 4 Operation 7 4 1 Start Up 7 4 2 Shut Down 7 4 3 Idle Time 7 5 Care and Maintenance 8 5 1 Cleaning the Lamp and Reflector 8 5 2 Removing the Lamp 8 5 3 Removing the Reflector 8 6 Troubleshooting 9 7 Recommended Spare Parts and Accessories 10 8 Warranty...

Страница 3: ...anual 1 3 For Your Safety IMPORTANT Do Not operate the unit before reading this section 1 3 1 Ultraviolet Light Safety The Loctite High Intensity Ultraviolet Source is a source of long wavelength ultraviolet light used to cure light sensitive products It produces intense ultraviolet UV light which can cause serious burns to the skin and eyes The light is similar to that which causes sunburn but is...

Страница 4: ...irect reading disposable detection tube which is capable of measuring ozone concentrations of 0 05 ppm to 14 ppm Ozone concentrations can be minimized with good local ventilation Ozone generation can be prevented entirely by the use of an oxygen excluding nitrogen atmosphere under the lamp or by using an ozone free lamp Ozone free lamps have a quartz sleeve or tube which blocks wavelengths 240 nan...

Страница 5: ...current production equipment the lamp unit can be mounted to existing conveyors and indexing equipment UV shielding is required to protect the operator A separately packaged power supply is powered by 120 VAC 20 Amp 60 Hz electrical power and can be located up to 5 feet from the lamp Power can be monitored with the built in watt meter A high low intensity switch 300 w inch to 200 w inch located on...

Страница 6: ...500 1500 1000 2000 BEFORE CLEANING OR RELAMPING ALWAYS TURN OR LAMP SHIELDING PROVIDED WHEN LAMP IS IN USE SUITABLE EYE AND SKIN PROTECTION MUST BE WORN NOT EXPOSED TO DIRECT OR REFLECTED RADIATION THE POWER OFF P N 980160 LOCTITE IS A TRADEMARK OF LOCTITE CORPORATION U S A Mexico 01 800 8499 412 Canada 1 800 263 5043 U S A 1 800 LOC TITE For Equipment Parts or Service LB 10322A 15 851 15 00 14 68...

Страница 7: ... THIS UNIT REQUIRES SHIELDING PRIOR TO OPERATION Ultraviolet light can cause severe burns Shielding must be provided to protect personnel from exposure to the UV light Any material that will block light will block the UV rays Use a heat resistant material near the lamp as the temperature of the lamp is between 600 C and 800 C 1112 F and 1472 F Sheet metal is a good screening material Total shieldi...

Страница 8: ...ed Position the lamp approximately 5 inches above the part Connect the 8 pin connector cable from the rear of the power supply to the socket on the rear of the lamp unit With both the Power Switch and the Lamp Switch in the Off position connect the Line Cord just prior to operation If two or more light sources are required the following is recommended 1 Lamp units should not be placed facing each ...

Страница 9: ... switch may be used to put the unit in an idle mode low Note When the intensity is switched back to high it is advisable to allow one minute for the lamp to reach full power monitor the watt meter to see when the lamp is ready 4 2 Shut Down 1 Move LAMP SWITCH to Off lamp pilot light goes off and watt meter will drop to 0 2 Allow fans to run for at least four minutes to cool the lamp Note Shutting ...

Страница 10: ... After cleaning wipe dry with a soft clean cotton cloth 5 2 Removing the Lamp 1 If unit has been in service allow at least 15 minutes for cooling before removing lamp 2 Unplug line cord 3 Unplug 8 pin connector from the rear of the lamp unit 4 Remove grills from both sides of the lamp unit Each grill has 4 screws 2 on the front and 2 on the side 5 Remove lamp bracket clamp screw and nut 6 Wearing ...

Страница 11: ...ching full Check input line voltage output intensity Reflector blackened Replace reflector Lamp reflector blackens Insufficient cooling has caused Add additional fans a local hot spot Replace reflectors Uneven cure Reflectors are warped Replace reflectors and distorted Lamp does not light Connector cable not Plug connector cable into lamp fully inserted unit socket 1 2 power relay not functioning ...

Страница 12: ...1 5 UV Lamp 980302 as required 5 UV Lamp Ozone Free 983192 2 Reflectors 983195 2 Lamp Holders 983196 2 Lamp Holder Focusing Springs 983197 2 Lamp Holder Brackets 983193 4 Guide Washers 983194 2 Reflector Extrusion Plates 983156 3 Capacitor 13uf 530 V 97210 as required UV Safety Glasses ...

Страница 13: ...se in connection with the Products are available from Loctite the use of products parts or attachments which are not manufactured by Loctite no claim shall be allowed No Products shall be returned to Loctite for any reason without prior written approval from Loctite Products shall be returned freight prepaid in accordance with instructions from Loctite NO WARRANTY IS EXTENDED TO ANY EQUIPMENT WHIC...

Страница 14: ...T VIEW 1 4 20 TAP LAMP UNIT PARTIAL BACK VIEW 8 PIN SOCKET OPERATE THIS EQUIPMENT WITH LIGHT GUARDS AND SHIELDS IN PLACE BECAUSE DIRECT ULTRAVIOLET LIGHT CAN HARM YOUR EYES AND SKIN WARNING ULTRAVIOLET LIGHT PLAN VIEW 7 38 75 75 15 19 6 19 7 59 4 06 8 75 ...

Страница 15: ...WER SUPPLY GRND L1 LINE CORD PLUG HOT LAMP UNIT GRND L2 NEUTRAL FAN IN LAMP FAN IN POWER SUPPLY POWER ON PILOT LIGHT HIGH LOW POWER RELAY LAMP ON PILOT LIGHT SW 1 SW 3 SW 2 OFF ON OFF ON C 1 C 2 C 3 CR 1 AMPS VOLTS WATTMETER BALLAST TRANSFORMER U V LAMP LOW HIGH 120 V 60 HZ 1 PH ...

Страница 16: ...ctite Company de México S A de C V Calzada de la Viga s n Fracc Los Laureles Loc Tulpetlac C P 55090 Ecatepac de Morelos Edo de México México Loctite Brazil Av Prof Vernon Krieble 91 06690 11 Itapevi São Paulo Brazil www loctite com Loctite and Zeta are trademarks of Loctite Corporation U S A Data in this manual is subject to change without notice Copyright 2001 Loctite Corporation All rights rese...

Отзывы: