4. Installation
• Keep the pressure hose as short as possible. Short switch-on and switch-off times for the
diaphragm valve are within reach.
• Keep product feed lines as short as possible. The shorter the feed line the smaller the specific
resistance and the lower the dispensing pressure can be.
• Avoid kinking of feed lines and pressure hoses.
• Typically, the pressure hose and product feed line should not be longer than 2 m.
• Do not use inflexible hoses and feed lines, so that unnecessary loads on the fittings will
be avoided.
• Keep all fittings tight.
• No direct sunlight; no UV light!
4.1 Connecting to the Product Reservoir
R
0.5 ltr
.: length 200 mm
2 ltr
.: length 275 mm