s
s
s
2. Place RF Tag on RF Tag reader after pressing button.
Master passcode button
1. Register & delete on door open position
2. Register of Passcode, RF Tag
[S]button 9button [S]button 71button button
1. Press registered passcode and button after touching the keypad and
getting backlight on.
9
11
12
Basic Functions
7
Outside force-lock function by passcode
Additional Functions
8
1. When door is locked, touch keypad and then number pad backlight will get on.
2. Press button during 3 seconds after pressing the passcode.
1. When door is locked, touch keypad and then number pad backlight will get on.
2. Press pa button.
Etiquette mode function
[Setting with passcode]
1. When door is locked, touch keypad and then number pad backlight will get on.
It allows turning on or turning off the buzzer sound when using digital door lock.
It is one time function which automatically is deactivated after the regular procedure.
Passcode hide function
Passcode hide function is to prevent someone from noticing the actual passcode.
This function gets rid of anxiety that there would be fingerprint on the pad.
When high temperature is detected, deadbolt switches automatically to open from
close and alarm goes off.
High temperature alert function
[What is high temperature alert function?]
High temperature function activates at 60°
C± 5°
C or higher and alarm goes off at
least 80dB.
When parts are separated improperly or someone try to invade by breaking the
door, intrusion alert alarm goes off more than 80dB.
1. 2 minutes alarm: [S] Button 7 Button [S] Button
2. Unending alarm: [S] Button 8 Button [S] Button
Intrusion alert function
[What is intrusion alert function?]
In case of entrance door malfunctioning due to deadbolt being stuck at the strike
or the door not being completely closed, buzzer sound goes off and keypad LED flickers.
Deadbolt jamming alert function
[What is the deadbolt jamming alert function?]
Try Open/Close 3 times.
Waring sound goes off if the problem is not resolved after the trial.
You will hear buzzer sound
‘beep beep beep beep’
.
It is deactivated when the door is properly closed.
1. Open battery cover and press [S] button.
2. From keypad, press 1 for mute/2 for low/3 for high.
3. Press [S] button.
Volume control function
[Setting volume control]
You can choose mute, low or high for the buzzer sound when using digital door lock.
You can hear buzzer sound‘beep beep beep beep’.
It is deactivated when the door is properly closed.
Low battery alert function
It is activated only after it detects low battery more than 3 times..
It remains activated even after power resets. It is deactivated only after replacing batteries.
Low battery voltage : 4.2V±
0.3
Prank Prevention function
Inside force-lock/release function
1. When door is locked, touch keypad and then number pad backlight will get on.
[Releasing Inside force-lock function with RF Tag]
2. Press button after entering registered passcode.
[Setting Inside force-lock funstion]
Press Inside force-lock button during 3 seconds.
In case there is malfunction in door lock, pressing
RESET button will set the program to factory settings.
※The registered passcode and RF Tag are kept after setting the
program to factory settings.
Reset function
Additional Functions
How to open door from outside
OR
OR
3. Open the door using by emergency key.
[What is Prank Prevention function?]
Additional Functions
[Replacing batteries]
How to change batteries
When you hear a buzzer melody, replace all of the batteries
.
Additional Functions
10
1. Use 1.5V AA authentic alkaline batteries.
2. Insert each battery according to the plus and minus sign inside the battery holder.
Please be cautious since improper insertion of the battery may cause leakage or
breakage.
3. After battery life is over, replace all the batteries at the same time and do not mix
new batteries with old ones.
Additional Functions
Auto/Manual lock setting
Door locks automatically certain time after the door opens or closes.
Manual lock setting keeps the door open at all times.
[What is passcode hide function?]
Wireless communication module registration (Optional Product)
※In case of opening the door from inside, this function is deactivated.
Specifications
- Door open alarm goes off when door opens under auto lock mode.
- Alarm occurs 2 times every 18 second.
Door open alert function
In case of low battery, low battery
buzzer sound goes off and LED starts to flicker.
You can hear buzzer melody.
2. Place RF Tag on RF Tag reader.
If you want to use the passcode hide function, press imaginary number (Max. 16digits)
then press the passcode.
Ex) Imaginary number (Max. 16P
■ Auto lock is activated when the door is not opened within 7 seconds.
■ When unregistered passcode is entered, you will hear error sound or see LED blinking.
■ When incorrect passcode is entered 5 consecutive times,
Prank Prevention function is activated.
■ If passcode is not entered within 7 seconds after pressing more than 1 button or
button, then the mode is terminated.
If door is opened from inside, alarm will be occurred.
It could be set once and automatically deactivated when door opens.
3. Place registered RF Tag on RF Tag reader, and then inside force-lock is released.
This function prohibits someone from opening the door using passcode or RF Tag from
outside. This function is useful during night time when extra caution for safety is required.
In case of a risk of passcode exposure, this function can be useful.
If you want to use this function, enter imaginary numbers(up to 16digits) before
entering the actual passcode.
Ex) Imaginary number should be up to 20 digits including passcode.
It checks for open mode every 3 seconds and tries to open if not in open mode.
It activates open mode to open even when inside or outside force lock function is activated.
It only activates open mode though pressing any button inside.
Alarm is deactivated when passcode is entered or RF Tag is placed.
Alarm goes off when someone try to open the door abnormally.
Alarm is deactivated when passcode is entered or RF Tag is placed.
When incorrect passcode or RF Tag is used for 5 consecutive times, the system
freezes for 30 seconds.
1. This is to provide temporary power when the door lock is not
functioning due to a complete discharge of batteries.
2. Use it while the battery is still in contact with the port.
3. When using emergency power, polarity of the battery does not matter.
When batteries are discharged, place 9V battery to emergency
power port in order to use the passcode.
- Door lock has a special design which prevents improper insertion of the battery
by not allowing any actions if the battery was installed incorrectly.
- Passcode and RF Tag information are kept when batteries are being replaced.
- Make sure the door lock works properly by entering passcode after replacing
batteries.
Opening door with emergency battery
Register is complete automatically when 10pcs master RF Tags are consecutively registered.
(Buzzer means 'be completed')
At delete mode, if place master RF Tag, all of the registered master RF Tags will be deleted.
It is useful function for group management
Register & delete function of Master passcode/Master RF Tag
Incapacitation function of usual user’s passcode and RF Tag
1. Open battery cover and press [S] button.
2. Press register/open button on the wireless communication module.
3. Press [S] button.
4. Press open button on the wireless module to see if door lock operates properly.
※Please register within 60 seconds.
※Can register 5pcs of wireless module continuously.
[Registering wireless communication module]
1. Open battery cover and press [S] button.
2. Press the number 5 button.
3. Press [S] button.
[Deleting wireless communication module]
[Setting with RF Tag]
Master RF Tag [S]button
[S]button 9button [S]button 73button button
3. Delete of Passcode, RF Tag
Master passcode button
[S]button 9button [S]button 91button button
Master RF Tag button
[S]button 9button [S]button 93button button
※ Incapacitation function is deactivated.
When door is open using master passcode or RF Tag,
82 Button Button Master passcode Button
82 Button Button RF Tag recognition
- When door is locked, touch keypad and then number pad backlight
will get on.
- When door is locked, touch keypad and then number pad
backlight will get on.
9V Alkaline battery(6LF22) 1EA (Optional Product)
Battery life depends on battery quality, usage frequency
or usage environment
1 year if used 10 times per day
Inbody 72(W) x 294(H) x 32(D)
/
R.F ABS / Al diecasting
Outbody 72(W) x 295(H) x 17.5(D) / Al diecasting
60℃ ±5℃
-20℃~60℃
Electronic & Mechanical (Passcode, RF Tag & Key)
6Vdc (4EA 1.5V AA Type Alkaline Batteries)
C200 Series
Frequency
Signal Type
Modulation Type
Certification number
Equipment name
Wireless equipment for RF ID / USN
13.56 MHz
A1D+F1D
ASK+FSK
MSIP - CMM - ICQ - C200B
※This product cannot carry on perfect security function.
You may want to install separate security system.
※Contents in user manual can be changed without notifying users in
order to improve product quality or service.
Problem
Check
Solution
When entering passcode,
buzze melody goes off.
After entering passcode, door
doesn’
t open.
When operating Open/Close,
motor stops after a while then
‘bleep bleep bleep’
buzzer
sound comes on.
It freezes while entering
passcode.
9V battery does not work when
used as emergency power.
Door does not lock automatically
after closing the door.
It’
s time to replace batteries.
It’
s time to replace batteries.
There is a deadbolt jam caused
by improper hinging of the
door and frame.
In case incorrect passcode
in entered 5 times, it goes to safe
mode for 60 seconds.
9V battery connection is bad.
Replace all of the batteries with
alkaline batteries.
Use 9V battery to open the door
and then replace all of the batteries.
Use door closer to adjust the door
and the frame.
Try again after 1 minute.
Reconnect 9V battery and try again.
Please call A/S center and request
service. Meanwhile switch to manual
mode to use the lock properly.
When Open/Close the door,
it feels like there is something
stuck or it is shaky
Bolt for motis or striker may
be loose.
Check the bolts for motis and striker
and tighten it if loose. Use super
glue if necessary.
Sensor may be defected or
magnet is displaced.
3.3Kg (Include packing)
Remote controller Registration (Optional Product)
1. Lift up the battery cover from the main body, then press the register button [S].
[To register the remote controller]
2. Press and hold the register button on the remote controller for 4 seconds.
3. Press the register button [S] on the main body.
4. Press the open button on the remote controller to see if the door lock
operates properly.
s
s
Model Name
Rated voltage
Type
Weight
Usage Temperature
Sensor activating
Temperature
Product size/Material
(width x length x depth)
Battery life
Emergency power
Product type
Direct current / Fire-proof / Temp. sensor / Key / Digital door lock
( D - F - T - K - M )
1. Lift up the battery cover from the main body, then press the register button [S].
[To delete remote controller]
2. Press 5 on the keypad.
3. Press the register button [S]
1
2
3
1
2
3
4
Perfect Protection
락프로
s
s
등록
동작
열림
InterCreative
※It determines to manual lock while switching over to close mode after open mode.
※To lock from outside, press more than 1 button on the keypad or press “ ”button.
[Auto lock setting]
- Open battery cover and set Auto/Manual switch to
‘Manual [M]’.
[Manual lock setting]
- Open battery cover and set Auto/Manual switch to
‘Auto [A]’.
※It determines to auto lock while switching over to close mode after open mode.
s
s
A
M
s
s
A
M