Thank you for purchasing the 

A

ccu

R

eader

 wafer reading system

 by LockTech

.  This system will 

allow you to read the KW14 keyways completely and 
accurately without the removal of the ignition. 
Following a few simple steps it takes only minutes to 
read the depths for each cut in each position for a 
complete key.

The 

A

ccu

R

eader works on the process of 

elimination to decipher the correct depths of the lock. 
By checking the deepest cut first you eliminate what 
the cuts are not.  Therefore it is essential to always 
read depth slide #4 first.

KW14 keyways are usually 6 space, but 

some utilize 7 spaces.  This KW14 AccuReader will 
read both 6 space and 7 space locks.  Use the 
reference guide to find out if your lock is 7 space or 6 
space and follow the appropriate directions.

The AccuReader key is designed to be used 

for wafer positions 4-7(7 space locks) or 3-6(6 space 
locks) on one side of the key and wafer positions 
1-3(7 space locks) or 1-2(6 space locks) on the 
opposite side of the key.  All the positions can be 
read from one side of the key, however it is 
recommended to flip the key over and use the other 
side.  This allows for reading the 1-3 or 1-2 wafer 
positions with a fully or almost fully inserted key, 
increasing the accuracy.

Please take the time to familiarize yourself 

with the tools and verify all pieces are accounted for 
from the list of contents below:

Package Contents:
1-AccuReader key
1-insertion/release slide
1-depth slide #4
1-depth slide #3
1-depth slide #2
1-Tube storage container
1-Tube Cap

USING THE ACCU-READER (7 space system)

1) Always thoroughly clean the lock with a electronics 

safe cleaner to free any potentially stuck wafers.

2) Use the alignment holes through the AccuReader 
key to assist in judging the distance from one wafer 
position to the next.

3) Place the insertion/release slide in the slot on the 

A

ccu

R

eader key on the #4-7 side.  Fully insert the 

A

ccu

R

eader key into the keyway and remove the 

slide.  The AccuReader key is now ready to read the 
#7 wafer.  

(Note:  If the AccuReader trapped a 

wafer shortly after inserting it into the keyway, 
use the release slide on the opposite side of the 
key to release the AccuReader.  This happens 
when wafers fall into the trap slot for the 1-3 side, 
since these locks have wafers only on one side. 
Flip the AccuReader over and restart step 2).

4) Always

 start reading with the #4 depth slide 

tool, then proceed to #3 & #2 in order, if 
necessary. 

 Fully insert the depth slide into the Accu-

Reader key.  The alignment mark on the depth slide 
will line up with the (

Y

Yes

 mark or it will line up with 

the (

N

)

 No 

mark. 

 

a) If the #4 depth slide lines up with the 

then the depth for the #7 wafer is a 4.  If the depth 
slide lines up with a 

N

, then you must 

proceed to the #3 depth slide. 
 

b) If the #3 depth slide lines up with the 

then the depth for the #7 wafer is a 3.  If the depth 
slide lines up with a 

N

, then you must 

proceed to the #2 depth slide.

c) If the #2 depth slide lines up with the 

then the depth for the #7 wafer is a 2.  If the depth 
slide lines up with a 

N

, then the depth for 

wafer #7 is a 1.

d) Repeat steps 

a

 through 

c

 for each wafer 

position until you have recorded the depth for wafer 
position 7, 6, 5, & 4.

e) Using the insertion/release slide remove 

the AccuReader key from the keyway and flip it over. 
Insert the insertion/removal slide on the #1-3 side of 
the AccuReader and fully insert the AccuReader 
key back into the keyway.  You are now ready to read 
wafer position #3.

f) Repeat steps a through c for each wafer 

position until you have recorded the depth for wafer 
position 3, 2, & 1.

g) You now have recorded all the positions to 

make a complete key.

USING THE ACCU-READER (6 space system)

1) Always thoroughly clean the lock with a electronics 

Отзывы: