background image

 
 
 

 

 

HYD19 

by    

 

 

 

 

www.accureader.com 

[email protected] 

 

 

Thank you for purchasing the AccuReader 

wafer reading system by LockTech.  This system will 
allow you to read the new Harley Davidson keyway, 
using the HYD19 key blank. The HYD19 AccuReader 
will read these locks completely and accurately 
without the removal of the ignition or other lock.    
Following a few simple steps it takes only minutes to 
read the depths for each cut in each position for a 
complete key.

 

 
 

The AccuReader works on the process of 

elimination to decipher the correct depths of the lock.  
By checking the deepest cut first you eliminate what 
the cuts are not.  Therefore it is essential to always 
read the deepest possible depth first, in this case the 
#3 slide. 
 
 

The AccuReader key is used for all wafer 

positions 1-8 for a complete key. 
 
Ignition = 1-8 
 

 

 

Please take the time to familiarize yourself 

with the tool and verify all pieces are accounted for 
from the list of contents below: 
 
Package Contents: 
 
1-AccuReader key 
1-insertion/release slide 
1-depth slide #3 
1-depth slide #2 
1-Tube storage container 
1-Tube Cap 
 

 
 
 
 

 
 
 
 
 
 
Using the HYD19 AccuReader 

 
Use the following directions to read all 8 wafer 
positions from the ignition.  After reading all 8 
positions from the ignition, it is sometimes helpful on 
dirty locks to read positions from the gas cap to 
compare your findings from the ignition. 
 

 
 
 
USING THE ACCU-READER 

 
  
1) Always thoroughly clean the lock with an 
electronics safe cleaner to free any potentially stuck 
wafers.  
  
2) Use the alignment holes through the AccuReader 
key to assist in judging the distance from one wafer 
position to the next.  
  
3) Place the insertion/release slide in the slot on the 
AccuReader key.  Fully insert the AccuReader key 
into the keyway and remove the slide.  The 
AccuReader key is now ready to read the space #8 
position.  (Note:  If the AccuReader fails to trap a 
wafer flip the AccuReader over and reinsert).  
  
4) Always start reading with the #3 depth slide tool, 
then proceed to #2 (ONLY if necessary).  Fully insert 
the depth slide into the AccuReader key.  The 
alignment mark on the depth slide will line up with the 
(Y) Yes mark or it will line up with the (N) No mark.   
  
  a) If the #3 depth slide lines up with the Y then the 
depth for the #8 wafer is a 3.  If the depth slide lines 
up with an N, then you must proceed to the #2 depth 
slide.     
 
 b) If the #2 depth slide lines up with the Y then the 
depth for the #8 wafer is a 2.  If the depth slide lines 
up with an N, then the depth for wafer #8 is a 1 
  
c) Repeat steps a) through c) for each wafer position 
until you have recorded the depths for wafer positions 
8-1.  
  
d) You now have recorded all the positions to make a 
complete key. 
 
 
 
 
 
 

Отзывы: