Installation & Operation Manual
22
First Hour Rating - 200°F Boiler Loop Water
(Universal Sizing - 45,000 - 225,000 Btu/hr)
Model
SIT040DW
SIT050DW
SIT065DW
Circulator Flow
GPM
5
8
12
16
20
25
30
5
8
12
16
20
25
30
5
8
12
16
20
25
30
Domestic Outlet
115 140 115 140 115 140 115 140 115 140 115 140 115 140 115 140 115 140 115 140 115 140 115 140 115 140 115 140 115 140 115 140 115 140 115 140 115 140 115 140 115 140
45,000
134 109
145 119
202 166
60,000
167 132
177 143
248 199
75,000
199 156
210 167
293 233
95,000
210 164 243 188
222 176 253 199
354 278
115,000
248 192 268 206 285 219 286 220
260 204 280 218 296 230
415 323
140,000
307 235 335 256 340 260
297 231 319 247 346 267 350 270 433 334 467 359 492 379
165,000
369 281
347 268 381 293
523 401 569 435
195,000
576 440 589 449 659 501 659 502
225,000
714 541
MAX BTU INPUT
81,087
98,603 107,683 115,469 125,746 140,766 154,389 81,087 98,603 107,683 115,469 125,746 140,766 154,389 121,955 132,982 151,146 168,661 173,202 195,905 214,070
Table 8D First Hour Rating - 200°F Boiler Loop Water (Universal Sizing)
First Hour Rating - 200°F Boiler Loop Water
(Universal Sizing - 45,000 - 225,000 Btu/hr)
Model
SIT080DW
SIT119DW
Circulator Flow
GPM
5
8
12
16
20
25
30
5
8
12
16
20
25
30
Domestic Outlet
115 140 115 140 115 140 115 140 115 140 115 140 115 140 115 140 115 140 115 140 115 140 115 140 115 140 115 140
45,000
213 177
247 211
60,000
259 211
293 245
75,000
305 244
339 278
95,000
366 289
400 323
115,000
427 334
461 368
140,000
450 351 484 376 504 391
478 379 512 404 538
165,000
540 418 580 447
568 446 614 481
195,000
593 457 606 466 671 514
621 485 634 494 704 546 705 547
225,000
676 518 731 558
759 586
MAX BTU INPUT
121,955 132,982 151,146 168,661 173,202 195,905 214,070 121,955 132,982 151,146 168,661 173,202 195,905 214,070
8
Performance data
Boiler Output Capacity
Boiler Output Capacity
Содержание Squire SIT040DW