MAINTENANCE

The following maintenance should be performed by a qualified service technician
at the minimum periodic intervals suggested below. In some installations, the

maintenance interval may be more frequent depending on the amount of use

and the operating conditions of the water heater.  Regular inspection and
maintenance of the water heater and vent-air intake system will help to ensure

safe and reliable operation.

1. Annually check the operation of the thermostat.

2. The flow of combustion and ventilation air MUST NOT be restricted. Clear

the combustion air openings of any dirt, dust, or other restrictions. WARNING!

The ventilation air system may be HOT.

3. At all times keep the water heater area clear and free from combustible

materials, gasoline and other flammable vapors and liquids.

4. Bi-annually conduct a visual check of the main and pilot burner flames to

determine that they are burning properly.  See Burner Flame Check section

on 

page 12

. If sooting or other burner anomalies are evident, shut down

the water heater by turning off the gas per the instructions listed in this

manual or as listed on the water heater.

5. Annually remove the inner door and main burner assembly to clean orifices

and related parts of any dirt or other foreign material. Inspect the burner
ports for obstructions or debris and clean with a wire brush as needed. Wire

brush and/or vacuum clean the combustion chamber as needed to remove

scale deposits and debris. 

NOTE:

 It is imperative for proper operation of

the water heater that the inner door be replaced in the original location.

7. At least once a year, check the combination temperature and pressure

relief valve to ensure that the valve has not become encrusted with lime.

Lift the lever at the top of the valve several times until the valve seats
properly without leaking and operates freely.

8. Monthly drain off a gallon of water to remove silt and sediment.

9. If the combination temperature and pressure relief valve on the appliance

discharges periodically, this may be due to thermal expansion in a closed

water supply system. Contact the water supplier or local plumbing inspector
on how to correct this situation. 

Do not plug the combination

temperature and pressure relief valve outlet.

10. A combination sacrificial anode rod/hot water outlet nipple has been

installed to extend tank life.The anode rod should be inspected periodically

(every 2 years) and replaced when necessary to prolong tank life. Water
conditions in your area will influence the time interval for inspection and

replacement of the anode rod. Contact the plumbing professional who

installed the water heater or the manufacturer listed on the rating plate
for anode replacement information. The use of a water softener may

increase the speed of anode consumption. More frequent inspection of the

anode is needed when using softened (or phosphate treated) water.

11. The induced draft blower has sealed motor bearings and does not require

adding oil.

Contact your supplier or plumbing professional for replacement parts or contact

the company at the address given on the rating plate of the water heater.

Provide the part name, model and serial numbers of the water heater when

ordering parts.

 

Figure 14

 WARNING

Water heaters are heat producing appliances. To avoid damage or injury there
shall be no materials stored against the water heater or vent-air intake system,
and proper care shall be taken to avoid unnecessary contact (especially by
children) with the water heater and vent-air intake system. 

UNDER NO

CIRCUMSTANCES SHALL FLAMMABLE MATERIALS, SUCH AS GASOLINE

OR PAINT THINNER BE USED OR STORED IN THE VICINITY OF THIS
WATER HEATER, VENT-AIR INTAKE SYSTEM OR IN ANY LOCATION

FROM WHICH FUMES COULD REACH THE WATER HEATER OR

VENT-AIR INTAKE SYSTEM.

IMPORTANT

The water heater should be inspected at a minimum annually by a

qualified service technician for damaged components and/or joints

not sealed. DO NOT operate this water heater if any part is found

damaged or if any joint is found not sealed.

 WARNING

When lifting lever of the combination temperature and

pressure relief valve, hot water will be released under

pressure. Be careful that any released water does not result

in bodily injury or property damage.

 CAUTION

FOR YOUR SAFETY, DO NOT ATTEMPT REPAIR OF COMBINATION GAS
CONTROL, BURNERS OR GAS PIPING. REFER REPAIRS TO A QUALIFIED
SERVICE TECHNICIAN.

 WARNING!

  THIS WATER MAY BE HOT..

Содержание RPV-I&S

Страница 1: ...ged in water You should contact a qualified service technician to inspect the appliance and to replace any part of the control system including the combination gas control which has been submerged in water Make sure that you check the rating plate and combination gas control on the water heater to be certain that the type of gas being supplied corresponds with the marking on the rating plate and c...

Страница 2: ... is recommended that a minimum clearance of four 4 inches 10 2 cm be provided on the side of the water heater for servicing and maintenance of the combination temperature and pressure relief valve MINIMUM CLEARANCES This installation must allow access to the front of the water heater and adequate clearance must be provided for servicing and operating this water heater The water heater may be insta...

Страница 3: ...ainst on installations where condensation can form in the venting system Formation of condensation in the venting system of Power Vented water heaters is dependent upon installation conditions including but not limited to 1 Ambient temperature and humidity of installation location 2 Ambient temperature and humidity of venting space vent distance and slope 3 And product usage In order to effectivel...

Страница 4: ... support brackets for every 3 feet 91 m of horizontal vent THROUGH THE ROOF VENTING VERTICAL VENTING Cut the necessary holes through the roof and ceiling and install the vent connector as shown in Figure 4 Make sure that the installation meets the local codes and or The National Fuel Gas Code ANSI Z223 1 Latest Edition or CGA CAN B149 Installation Code Figure 2 TABLE 3 VENT CONNECTOR LENGTHS FOR 4...

Страница 5: ...ing with 3 7 6 cm PVC use a 3 7 6 cm to 2 5 1 cm reducer to exit through the building wall with 2 5 1 cm PVC Use the 2 5 1 cm vent terminal supplied with the water heater to terminate on the outside of the building If the length of the 2 5 1 cm needed to go through the wall is greater than 14 35 6 cm use 3 7 6 cm PVC to go through the wall and reduce to 2 5 1 cm PVC immediately after exiting the o...

Страница 6: ... and or The National Fuel Gas Code ANSI Z223 1 Latest Edition or CGA CAN B149 Installation Code THROUGH THE WALL VENTING WITH LOW GROUND CLEARANCE When venting cannot exit through the wall at a height greater than or equal to 12 30 5 cm from the ground or from the anticipated snow level then the installation must be modified as shown below see Figure 10 Refer to Table 9 for maximum venting lengths...

Страница 7: ...zation equipment in the confined space but not less than 100 square inches 645 cm2 One opening must be within 12 inches 31 cm of the top and one within 12 inches 31 cm of the bottom of the enclosure All Air From Outdoors The confined space must be provided with two permanent openings one commencing within 12 inches 31 cm of the top and one commencing within 12 inches 31 cm from the bottom of the e...

Страница 8: ...ble from the local plumbing supplier Please consult with a plumbing professional CAUTION If sweat fittings are to be usedDO NOT apply heat to the nipples on top of the water heater Sweat the tubing to the adapter before fitting the adapter to the waterconnections Itisimperativethatheatisnotappliedtothenipplescontaining a plastic liner WARNING FAILURE TO INSTALL AND MAINTAIN A NEW LISTED 3 4 X 3 4 ...

Страница 9: ...supply to the corresponding locations that were connected to the flexible line cord The wiring diagram for the 48 gal 65 000 BTU 181 7 L 19 1 Kw Hr 65 gal 65 000 BTU 246 1 L 19 1 Kw Hr and 75 gal 76 000 BTU input 283 9 L 22 3 Kw Hr models is located in Figure 11 on page 10 The wiring diagram for the 40 gal 40 000 BTU 151 4 L 11 7 Kw Hr and 48 gal 40 000 BTU 181 7 L 11 7 Kw Hr models are located in...

Страница 10: ...10 RPV I S Figure 11 ...

Страница 11: ...11 RPV I S Figure 12 ...

Страница 12: ...anual gas control valve to the appliance and call a qualified service technician Note Whenever the water heater is filled with cold water condensate will form on the cool tank surface and drops of water will fall on the hot burner and combustion chamber surfaces producing a sizzling noise Condensation is normal and does not indicate a leak It will disappear when the tank becomes heated FOR YOUR SA...

Страница 13: ...pplier or local plumbing inspector on how to correct this situation Do not plug the combination temperature and pressure relief valve outlet 10 A combination sacrificial anode rod hot water outlet nipple has been installed to extend tank life The anode rod should be inspected periodically every 2 years and replaced when necessary to prolong tank life Water conditions in your area will influence th...

Страница 14: ...icals such as those used for boiler treatment must not be introduced into potable water used for space heating 3 This water heater must not be connected to an existing heating system or component s previously used with a non potable water heating appliance 4 When the system requires water for space heating at temperatures higher than required for other means a tempering valve must be installed to ...

Страница 15: ...l c Applicator Tools i A pure bristle paintbrush or roller may be used to apply cement Prompt application of the cement is important due its fast drying properties 3 Inspection Cleaning Priming and Cementing a Inspect the pipe inside and out for dirt dust moisture or grease etc Check pipe and fittings for splits or cracks and replace if necessary b Clean pipe and fittings are imperative for proper...

Страница 16: ...16 RPV I S Printed in USA ...

Отзывы: