GENERAL REQUIREMENTS
The Lochinvar EcoShield condensing water heater has been designed to operate trouble free for many years.
These instructions should be followed closely to obtain the maximum usage and efficiency of the equipment.
PLEASE
read the instructions fully before installing or using the appliance.
4.1
RELATED DOCUMENTS
It is law that all gas appliances are installed by competent persons, in accordance with The Gas Safety
(Installation and Use) Regulations 1998. Failure to install appliances correctly could lead to prosecution. It is in
your own interest, and that of safety, to ensure that this law is complied with.
The installation of the equipment
MUST
be in accordance with the relevant requirements of the Gas Safety
Regulations, Building Regulations, I.E.E. Regulations and the bylaws of the local water undertaking. The
installation should also be in accordance with any relevant requirements of the local gas distributor and local
authority.
In addition the installation should follow the relevant guidance offered in the following documents. It is not
practical to list all relevant information but emphasis is placed on the following documents, as failure to comply
with the guidance given will almost certainly result in an unsatisfactory installation:
BS EN 1858: 2003
Chimneys. Components. Concrete flue blocks
BS 5440-1: 2008
Flueing and ventilation for gas appliances of rated input not exceeding 70kW net
(1st, 2nd and 3rd family gases). Specification for installation of gas appliances to
chimneys and for maintenance of chimneys.
BS 5440-2: 2009
Installation and maintenance of flues and ventilation for gas appliances of rated input
not exceeding 70kW net (1st, 2nd and 3rd family gases). Specification for
installation and maintenance of ventilation for gas appliances
BS 6644: 2005
Specification for Installation of gas-fired hot water boilers of rated inputs between
70kW
+ A1:2008
(net) and 1.8MW (net) (2
nd
and 3
rd
family gasses)
BS 6700: 1997
Design, installation, testing and maintenance of services supplying water for
domestic use within buildings and their curtilages
BS 6880: 1988
Code of practice for low temperature hot water systems of output greater than 45kW
Parts 1, 2 and 3
BS 7074: 1989
Application, selection and installation of expansion vessels and ancillary equipment
for
Parts 1and 2
sealed systems
BS 7671: 2008
Requirements for electrical installations, I.E.E. wiring regulations Seventeenth
edition
CP 342:
Code of practice for centralised hot water supply-buildings other than dwellings
Part 2 1974
IGE/UP/1:
Installation pipework on industrial and commercial premises
Edition 2
IGE/UP/2:
Gas installation pipework, boosters and compressors on industrial and
commercial
Edition 2
premises
IGE/UP/4:
Commissioning of gas-fired plant on industrial and commercial premises
Edition 2