21
10.9
INSTALLATION OF TRANSITION KIT TO EKW86CE WATER HEATERS
10.9.1
FLUE
TRANSITION
PARTS
EKW86CE
Depending upon the flue kit chosen either a vertical or horizontal concentric terminal will be included in
the packaging with the transition kit, additional elbows, flue lengths etc. Are available as ancillary items.
Additional wall brackets may be required to ensure the flue system is stable.
For a full list of flue components supplied and optional parts to complete the system see the EcoKnight™
flue guide available at
ITEM NUMBER
DESCRIPTION
EKW 86
1
90
⁰
ELBOW
3 REQUIRED
2
45
⁰
ELBOW
1 REQUIRED
3
SAMPLING POINT
1 REQUIRED
4
CONCENTRIC ADAPTOR
1 REQUIRED
5
AIR INTAKE TRANSITION
1 REQUIRED
6 (a)
100mm X 500mm LENGTH
KEEP 500mm
6 (b)
100mm X 500mm LENGTH
CUT TO 330mm
6 (c)
100mm X 500mm LENGTH
CUT TO 330mm
10.9.2
FLUE
TRANSITION
PARTS
EKW86CE