background image

10

WATER PIPING

HOTTER  WATER  CAN  SCALD: 
Water heaters are intended to produce hot water.  Water heated to a 
temperature which will satisfy space heating, clothes washing, dish 
washing, cleaning and other sanitizing needs can scald and permanently 
injure you upon contact.  Some people are more likely to be permanently 
injured by hot water than others.  These include the elderly, children, the 
infi rm, or physically/mentally handicapped.  If anyone using hot water in 
your home fi ts into one of these groups or if there is a local code or state 
law requiring a certain temperature water at the hot water tap, then you 
must take special precautions.  In addition to using the lowest possible 
temperature setting that satisfi es your hot water needs, a means such as 
a *mixing valve, shall be used at the hot water taps used by these people 
or at the water heater, see Figure 2.  Valves for reducing point of use 
temperature by mixing cold and hot water are also available. Consult 
a Qualifi ed Installer or Service Agency.  Follow  manufacturer’s 
instructions for installation of the valves.  Before changing the factory 
setting on the thermostat, read the “Temperature Regulation” section 
in this manual.

This water heater shall not be connected to any heating systems 
or component(s) used with a non-potable water heating appliance.

All piping components connected to this unit for space heating 
applications shall be suitable for use with potable water.

Toxic chemicals, such as those used for boiler treatment shall not be 
introduced into this system.

When the system requires water for space heating at temperatures 
higher than required for domestic water purposes, a tempering valve 
must be installed.  Please refer to Figure 2 for suggested piping 
arrangement.

Water supply systems may, because of such events as high line 
pressure, frequent cut-offs, the effects of water hammer among others, 
have installed devices such as pressure reducing valves, check valves, 
back fl ow preventers, etc. to control these types of problems.  When 
these devices are not equipped with an internal by-pass, and no other 
measures are taken, the devices cause the water system to be closed.  

INSTALLING THE NEW WATER HEATER

As water is heated, it expands (thermal expansion) and closed systems 
do not allow for the expansion of heated water.

The water within the water heater tank expands as it is heated and 
increases the pressure of the water system.  If the relieving point of the 
water heater’s temperature-pressure relief valve is reached, the valve 
will relieve the excess pressure.  

The temperature-pressure relief 

valve is not intended for the constant relief of thermal expansion.

  

This is an unacceptable condition and must be corrected.
It is recommended that any devices installed which could create a 
closed system have a by-pass and/or the system have an expansion 
tank to relieve the pressure built by thermal expansion in the water 
system.  Expansion tanks are available for ordering through a local 
plumbing contractor.  Contact the local water supplier and/or a service 
agency for assistance in controlling these situations.

NOTE:

 

To protect against untimely corrosion of hot and cold 

water fi ttings, it is strongly recommended that di-electric unions 
or couplings be installed on this water heater when connected 
to copper pipe.

FIGURE 10.

Содержание COMMERCIAL GAS WATER HEATERS

Страница 1: ...IL AT 2TECH LOCHINVAR COM COMMERCIAL GAS WATER HEATERS For Your Safety AN ODORANT IS ADDED TO THE GAS USED BY THIS WATER HEATER C3 Technology Gas Water Heaters meet the new ANSI Z21 10 1 standard that...

Страница 2: ...it relates to the installation of gas fired water heaters The qualified installer must also be familiar with the design features and use of flammable vapor ignition resistant water heaters and have a...

Страница 3: ...3 GENERAL SAFETY...

Страница 4: ...follow the safety rules the water heater will not operate properly It could cause DEATH SERIOUS BODILY INJURY AND OR PROPERTY DAMAGE This manual contains instructions for the installation operation an...

Страница 5: ...Y LOCAL CODES FIGURE 1 J Drip Leg Sediment Trap K Inner Door L Outer door M Union N Inlet Water Shut off Valve O Cold Water Inlet P Inlet Dip Tube Q Temperature Pressure Relief Valve R Rating Plate S...

Страница 6: ...others These include the elderly children the infirm or physically mentally handicapped If anyone using hot water in your home fits into one of these groups or if there is a local code or state law re...

Страница 7: ...larm or turn off the incoming water to the water heater when leakage is detected Sensors mounted in the drain pan that turn off the water supply to the entire home when water is detected in the drain...

Страница 8: ...al injury or death Do not apply insulation to the top of the water heater as this will interfere with safe operation of the draft hood Do not cover the outer door thermostat or temperature pressure re...

Страница 9: ...1 cm2 kW of total input rating of all equipment in the enclosure see Figure 9 Alternatively a single permanent opening may be used when communicating directly with the outdoors or with spaces that fre...

Страница 10: ...uires water for space heating at temperatures higher than required for domestic water purposes a tempering valve must be installed Please refer to Figure 2 for suggested piping arrangement Water suppl...

Страница 11: ...ctly into the fitting of the water heater designed for the relief valve Position the valve downward and provide tubing so that any discharge will exit only within 6 inches 153 mm above or at any dista...

Страница 12: ...ion For replacement heater installations where using pre existing venting venting must be inspected for obstructions and if deterioration is present venting must be replaced To insure proper venting o...

Страница 13: ...ing all gas appliances is used also turn off the gas at each appliance Leave all gas appliances shut off until the water heater installation is complete A gas line of sufficient size must be run to th...

Страница 14: ...trol valve of the water heater can be accomplished by either of the two methods shown in Figures 13 and 14 A sediment trap shall be installed as close to the inlet of the water heater as practical at...

Страница 15: ...burner It can be located by looking through the glass view port while pressing the piezo ignitor button several times Look for a spark at the pilot location see Figure D 9 Once the pilot has been foun...

Страница 16: ...htubs showers sink etc HOTTER WATER CAN SCALD Water heaters are intended to produce hot water Water heated to a temperature which will satisfy space heating clothes washing dish washing and other sani...

Страница 17: ...urner area during heating and cooling periods and should be considered normal See Condensation in this section OPERATIONAL CONDITIONS SMELLY WATER In each water heater there is installed at least one...

Страница 18: ...able However over a period of time a flooded water heater will create dangerous conditions which can cause DEATH SERIOUS BODILY INJURY OR PROPERTY DAMAGE Contact a qualified installer or service agenc...

Страница 19: ...s to completely reset and continues to release water immediately close the cold water inlet to the water heater follow the draining instructions and replace the temperature pressure relief valve with...

Страница 20: ...d drip onto the burner or run on the floor This is common at the time of start up after installation and when incoming water is cold I Water in the water heater bottom or on the floor may be from cond...

Страница 21: ...ional 26 Instruction Manual 27A Nipple with Heat Trap 27B Secondary Anode with Heat Trap Not Shown Now that you have purchased this water heater should a need ever exist for repair parts or service si...

Страница 22: ...nctions Thermocouple TCO malfunction Replace pilot assembly High ambient room temperature Contact a service agency to determine cause BURNER WILL NOT Dirty or clogged air intake screen Clean and reins...

Страница 23: ...23 NOTES...

Страница 24: ...24 300 Maddox Simpson Parkway Lebanon TN 37090 Phone 615 889 8900 Fax 615 547 1000 Technical Services email 2tech lochinvar com www lochinvar com Copyright 2011 Lochinvar LLC All rights reserved...