background image

35

LIMITED WARRANTY

Limited Warranty

 

 

1. THE TANK 

If the glass-lined tank in this water heater shall prove upon examination by the warrantor to have leaked due to natural corrosion from potable water therein, 

during the first THREE years after initial installation, the warrantor will supply a complete new Lochinvar water heater of equivalent size and current model at the 

warrantor's option. Some government agencies are requiring energy efficient standards for water heaters. In the event regulations prohibit sale of a model of 

equivalent size and construction, Lochinvar will provide a model which complies with the regulations of your area, in which case the consumer will be charged the 

difference in price between the like replacement and the energy efficient model required. The warranty on the replacement water heater will be limited to the 

unexpired term of the original warranty. 

 

2. ALL OTHER PARTS 

If within ONE year after initial installation of this water heater, any part or portion shall prove upon examination by the warrantor to be defective in material or 

workmanship, the warrantor will repair or replace such part or portion at its option. 

 

3. CONDITIONS AND EXCEPTIONS 

This warranty shall apply only when the water heater is installed in accordance with local plumbing and building codes, ordinances and regulations, the printed 

instructions provided with it and good industry practices. In addition, a temperature and pressure relief valve, certified by CSA and approved by the American 

Society of Mechanical Engineers, must have been installed. 

a. This warranty shall apply only when the water heater is: 

(1) owned by the original purchaser; 

(2) used at temperatures not exceeding the maximum setting of its thermostat; 

(3) used at water pressure not exceeding the working pressure shown on the heater; 

(4) used when operated free of the damaging effects of uncontrolled water hammer; 

(5) used when filled with potable water, free to circulate at all times; 

(6) used in a non-corrosive and non-contaminated atmosphere; 

(7) used with factory approved anode(s) installed; 

(8) in its original installation location; 

(9) in the United States, its territories or possessions, and Canada; 

(10) sized in accordance with proper sizing techniques for commercial water heaters; 

(11) bearing a rating plate which has not been altered, defaced or removed except as required by the warrantor; 

(12) fired at the factory rated input using the fuel stated on the rating plate in the case of gas models or fired at the proper voltage and wattage in the 

case of electric models 

(13) maintained in accordance with the instructions printed in the manual included with the water heater. 

b. Any accident to the water heater, any misuse, abuse (including freezing) or alteration of it, any operation of it in a modified form, or any attempt 

to repair tank leaks will void this warranty. 

c. This warranty is void if a device acting as a backflow prevention device (check valves etc.) is installed in the cold water supply the heater is 

connected to, unless an effective method of controlling thermal expansion is also installed at the heater(s) and operational at all times. 

The temperature and pressure relief valve installed on the heater is not an acceptable method. 

 

4. SERVICE AND REPAIR EXPENSES 

Under the limited warranty the warrantor will provide only a replacement water heater or part thereof. The owner is responsible for all other costs. Such costs 

may include but are not limited to: 

a. Labor charges for service removal, repair or reinstallation of the water heater or any component part; 

b. Shipping, delivery, handling, and administrative charges for forwarding the new heater or replacement part from the nearest distributor and returning 

the claimed defective heater or part to such distributor. 

c. All cost necessary or incidental for any material and/or permits required for installation of the replacement. 

 

5. LIMITATIONS ON IMPLIED WARRANTIES 

Implied warranties, including the warranty of merchantability imposed on the sale of this heater under state law are limited to one (1) year duration for the heater 

or any of its parts. Some states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you. 

 

6. CLAIM PROCEDURE 

Any claim under the warranty should be initiated with the dealer who sold the water heater, or with any other dealer handling the warrantor’s 

products. If this is not practicable, the owner should contact: 

a. The warrantor will only honor replacement with identical or similar water heater or parts thereof which are manufactured or distributed by the 

warrantor. 

b. Dealer replacements are made subject to in-warranty validation by warrantor. 

 

7. DISCLAIMERS 

NO OTHER EXPRESS WARRANTY HAS BEEN OR WILL BE MADE IN BEHALF OF THE WARRANTOR WITH RESPECT TO THE MERCHANTABILITY 

OF THE HEATER OR THE INSTALLATION, OPERATION, REPAIR OR REPLACEMENT OF THE WATER HEATER. THE WARRANTOR SHALL NOT BE 

RESPONSIBLE FOR WATER DAMAGE, LOSS OF USE OF THE UNIT, INCONVENIENCE, LOSS OR DAMAGE TO PERSONAL PROPERTY OR OTHER 

CONSEQUENTIAL DAMAGE. THE WARRANTOR SHALL NOT BE LIABLE BY VIRTUE OF THIS WARRANTY OR OTHERWISE FOR DAMAGE TO ANY 

PERSONS OR PROPERTY, WHETHER DIRECT OR INDIRECT, AND WHETHER ARISING IN CONTRACT OR TORT. 

a. Some states do not allow the exclusion or limitation of the incidental or consequential damage, so the above limitations or exclusions may not apply to 

you. 

b. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state. 

Fill in the following for your own reference. Keep it. Registration is not a condition of warranty. The model and serial number are found on the heater’s rating plate. 

 

Date Installed________________________Model No.____________________________________________Serial No._________________________________________ 

Dealer’s Name _____________________________________________________________________Phone No.________________________________________________ 

Dealer’s Address__________________________________________________City and State________________________________________Zip Code________________ 

FILL IN WARANTY AND KEEP FOR FUTURE REFERENCE

 

Lochinvar, LLC the warrantor, extends the following LIMITED WARRANTY to the owner of this water heater. 

Lochinvar, LLC 

300 Maddox Simpson Pkwy 

Lebanon, TN 37090 

(615) 889-8900 

Содержание CLN 075100

Страница 1: ...erious injury This manual must remain with the water heater WARNING If the information in these instructions is not followed exactly a fire or explosion may result causing property damage personal inj...

Страница 2: ...Fresh Air Openings for Confined Spaces 13 Outdoor Air Through Two Openings 13 Outdoor Air Through One Opening 13 Outdoor Air Through Two Horizontal Ducts 14 Outdoor Air Through Two Vertical Ducts 14 A...

Страница 3: ...ornia to cause cancer birth defects or other reproductive harm and requires businesses to warn of potential exposure to such substances WARNING This product contains a chemical known to the State of C...

Страница 4: ...4 GENERAL SAFETY INFORMATION...

Страница 5: ...you don t follow the safety rules the water heater will not operate properly It could cause DEATH SERIOUS BODILY INJURY AND OR PROPERTY DAMAGE This manual contains instructions for the installation op...

Страница 6: ...2 12 1 2 CM 157 6 147 3 74 9 64 1 40 3 10 2 38 7 40 6 5 1 NPT NPT 31 8 F 30 40 50 60 70 80 90 100 110 120 130 140 GPH 246 184 147 123 105 92 82 74 67 61 57 53 C 17 22 28 33 39 44 50 56 61 67 72 78 LPH...

Страница 7: ...vicing and proper operation of the water heater Installation of water heater must be accomplished in such a manner that if the tank or any connections should leak flow will not cause damage to the str...

Страница 8: ...proper and inefficient operation of the water heater producing carbon monoxide gas in excess of the safe limits This could result in serious injury or death Contact your local gas supplier for any spe...

Страница 9: ...rtain it does not sag thereby obstructing the combustion air flow HARD WATER Where hard water conditions exist water softening or the threshold type of water treatment is recommended This will protect...

Страница 10: ...to manufacturer s specifications If a positive lock up regulator is required follow these instructions 1 Positive lock up gas pressure regulators must be rated at or above the input Btu hr rating of t...

Страница 11: ...s not intended for the constant relief of thermal expansion A properly sized thermal expansion tank must be installed on all closed systems to control the harmful effects of thermal expansion Contact...

Страница 12: ...ature Pressure Relief Valve discharge line and 2 the water manually discharged will not cause any bodily injury or property damage because the water may be extremely hot If after manually operating th...

Страница 13: ...eater and the risk of fire or explosion may result It can also create a risk of asphyxiation LOUVERS AND GRILLES Thefreeareasofthefreshairopeningsintheinstructionsthatfollowdonot takeintoaccountthepre...

Страница 14: ...e provided with two permanent vertical ducts one commencing within 12 inches 300 mm of the top and one commencing within 12 inches 300 mm of the bottom of the enclosure The vertical ducts shall commun...

Страница 15: ...er heater unless it is vented to the outdoors and has adequate air supply to avoid risks of improper operation explosion or asphyxiation Align the legs of the draft hood with the holes provided Insert...

Страница 16: ...IN INCHES MAXIMUM CAPACITY OF PIPE IN CUBIC FEET PER HOUR LENGTH IN FEET NOMINAL IRON PIPE SIZES INCHES INPUT IN THOUSANDS BTU HR 1 2 3 4 1 1 1 4 1 1 2 2 2 1 2 3 4 10 175 360 680 1400 2100 3960 6300 1...

Страница 17: ...allation shown in the Figures 15 and 16 Contaminants in the gas lines may cause improper operation of the gas control valve that may result in fire or explosion Before attaching the gas line be sure t...

Страница 18: ...ter several tries turn the gas control knob clockwise to OFF and call your service technician or gas supplier SEE FIGURE A DANGER Hotter water increases the risk of scald injury Consult the instructio...

Страница 19: ...r at the water heater Mixing valves are available at plumbing supply or hardware stores see Figure 6 Follow manufacturer s instructions for installation of the valves Before changing the factory setti...

Страница 20: ...rmal See Condensation in this section OPERATIONAL CONDITIONS SMELLY WATER In each water heater there is installed at least one anode rod for corrosion protection of the tank Certain water conditions w...

Страница 21: ...ll with a blue haze and small amounts of yellow or orange at the edges After several minutes of operation the burner screen may glow red You should check for sooting Soot is not normal and will impair...

Страница 22: ...of the hardness lime For this reason it is recommended that a regular schedule for deliming be maintained ANODE ROD INSPECTION Property Damage Hazard Avoid water heater damage Inspection and replaceme...

Страница 23: ...TANK 1 Turn off gas supply at the Main Gas Shutoff Valve if the water heater is going to be shut down for an extended period 2 Ensure the cold water inlet valve is open 3 Open a nearby hot water fauc...

Страница 24: ...an condense on the cooler surfaces of the tank Droplets form and drip onto the burner or run on the floor This is common at the time of start up after installation and when incoming water is cold I Wa...

Страница 25: ...Gas Control Replace Gas Control PILOT OUTAGE Dirty pilot burner Clean pilot assembly Thermocouple malfunction Replace pilot assembly and or thermocouple Defective Gas Control Replace Gas Control Ther...

Страница 26: ...ocal codes shall govern their usage 4 The Tank Temperature Control should be wired to and control the pump between the water heater s and the storage tank s 5 The water heater s operating thermostat s...

Страница 27: ...mostat should be set 5 degrees F higher than the Tank Temperature Control SINGLE FLUE 1 UNIT WITH VERTICAL STORAGE TANK LEGEND TEMPERATURE PRESSURE RELIEF VALVE PRESSURE RELIEF VALVE CIRCULATING PUMP...

Страница 28: ...ermostat should be set 5 degrees F higher than the Tank Temperature Control SINGLE FLUE 1 UNIT WITH HORIZONTAL STORAGE TANK LEGEND TEMPERATURE PRESSURE RELIEF VALVE PRESSURE RELIEF VALVE CIRCULATING P...

Страница 29: ...ired to and control the pump between the water heater s and the storage tank s 5 The water heater s operating thermostat should be set 5 degrees F higher than the Tank Temperature Control SINGLE FLUE...

Страница 30: ...rature Control should be wired to and control the pump between the water heater s and the storage tank s 5 The water heater s operating thermostat should be set 5 degrees F higher than the Tank Temper...

Страница 31: ...he pump between the water heater s and the storage tank s 5 The water heater s operating thermostat should be set 5 degrees F higher than the Tank Temperature Control SINGLE FLUE 2 UNITS TWO TEMPERATU...

Страница 32: ...32 NOTES...

Страница 33: ...33 NOTES...

Страница 34: ...34 NOTES...

Страница 35: ...ion is also installed at the heater s and operational at all times The temperature and pressure relief valve installed on the heater is not an acceptable method 4 SERVICE AND REPAIR EXPENSES Under the...

Страница 36: ...36 300 Maddox Simpson Parkway Lebanon TN 37090 Phone 615 889 8900 Fax 615 547 1000 Technical Service email 2tech lochinvar com www Lochinvar com Copyright 2015 Lochinvar LLC All rights reserved...

Отзывы: