Draining
44
Instruction manual CHA
6
gis
6.1
Draining unvented
installations
Some service activities require the water heater to be drained. The procedure
is as follows:
1. Shut down the appliance by setting the ON/OFF switch on the control panel
to
position 0
.
2. Isolate the water heater from the power supply by putting the isolator
between the appliance and the mains power supply to position 0.
3. Shut off the gas supply (10).
4. Close the stop valve (11) in the hot water pipe.
5. Close the supply valve of the cold water supply (A).
6. Open the drain valve (9).
7. Bleed the appliance (or installation) so that it drains completely.
6.2
Draining vented
installations
Some service activities require the water heater to be drained. The procedure
is as follows:
1. Shut down the appliance by setting the ON/OFF switch on the control panel
to
position 0
.
2. Isolate the water heater from the power supply by putting the isolator
between the appliance and the mains power supply to position 0.
3. Shut off the gas supply (10).
4. Close the stop valve (11) in the hot water pipe.
5. Close the stop valve (4) between the cold water head tank and the cold
water inlet.
6. Open the drain valve (9).
7. Bleed the appliance (or installation) so that it drains completely.
0063
RESET
4
3
1
2
IMD-0473 R1
0063
RESET
4
3
1
2
IMD-0473 R1
Содержание CHA 100 CE
Страница 4: ...4 Instruction manual CHA gis...
Страница 10: ...Introduction 10 Instruction manual CHA 1 gis...
Страница 32: ...Installation 32 Instruction manual CHA 3 is...
Страница 40: ...Conversion to a different gas category 40 Instruction manual CHA 4 is...
Страница 50: ...Starting the water heater 50 Instruction manual CHA 9 gis...
Страница 52: ...Shutting down 52 Instruction manual CHA 10 gis...
Страница 70: ...Electrical diagram 70 Instruction manual CHA 14 is...
Страница 72: ...Declaration of Conformity 72 Instruction manual CHA 15 is...
Страница 74: ...0310 569 1 0 UK Index Instruction manual CHA...