User’s Information Manual

Models:  80 - 500

Starting Serial #H05H10003637

If the information in this manual is not followed
exactly, a fire or explosion may result causing
property damage, personal injury or loss of life.

This appliance MUST NOT be installed in any
location where gasoline or flammable vapors are
likely to be present.

WHAT TO DO IF YOU SMELL GAS

• Do not try to light any appliance.
• Do not touch any electric switch; do not use any 

phone in your building.

• Immediately call your gas supplier from a 

neighbor’s phone.

Follow the gas supplier’s 

instructions.

• If you cannot reach your gas supplier, call the fire 

department.

• Installation and service must be performed by a 

qualified installer, service agency, or the gas 
supplier.

WARNING

Save this manual for future reference.

Содержание 80 - 500

Страница 1: ...flammable vapors are likely to be present WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electric switch do not use any phone in your building Immediately call your gas...

Страница 2: ...life of the product DANGER WARNING CAUTION CAUTION NOTICE DANGER indicates an imminently hazardous situation which if not avoided will result in death or serious injury WARNING indicates a potentiall...

Страница 3: ...al supply to the circulator Instead shut off the gas supply at a location external to the appliance Do not use this boiler if any part has been under water The possible damage to a flooded appliance c...

Страница 4: ...hments Swimming pools Metal fabrication plants Beauty shops Refrigeration repair shops Photo processing plants Auto body shops Plastic manufacturing plants Furniture refinishing areas and establishmen...

Страница 5: ...re than 54 F above return water temperature If combustion or performance indicate need Clean heat exchanger Remove and clean burner using compressed air only Clean the blower wheel Owner maintenance s...

Страница 6: ...or fluorine if allowed to contaminate the boiler intake air will cause acidic condensate in the boiler This will cause significant damage to the boiler if allowed to continue Read the list of potentia...

Страница 7: ...Call your qualified service technician to inspect the boiler and system 5 Leave the top of the 1 2 inch tee OPEN This is needed as a vacuum break 6 Do not expose condensate line to freezing temperatu...

Страница 8: ...s on pages 9 and 10 of this manual Call your qualified service technician to inspect the boiler and system Shut boiler down unless boiler is used for Domestic Water 1 Follow To Turn Off Gas to Applian...

Страница 9: ...User s Information Manual 9 3 Operating instructions Models 80 285...

Страница 10: ...User s Information Manual 10 3 Operating instructions 3 Operating instructions Models 399 500...

Страница 11: ...s Information Manual 11 4 SMART SYSTEM control module Figure 4 Control Panel Knight boiler control module Use the control panel FIG 4 to set temperatures operating conditions and monitor boiler opera...

Страница 12: ...the installer access code Have your qualified service technician reference the Knight Boiler Service Manual Saving parameters reference parameter table on page 13 of this manual To save parameters an...

Страница 13: ...es Yes Yes 7 Night Setback Times 14 Yes Yes Yes Yes B 1 SH Set Point User 14 Yes Yes Yes Yes E 1 DHW Boiler Set Point 15 Yes Yes Yes Yes 2 SH DHW Switching Time 15 Yes Yes Yes Yes F 5 Outdoor Air Shut...

Страница 14: ...an be changed by the user or the installer by accessing parameter A6 The temperature range for this parameter is 32 F to 140 F The feature is turned off with a setting of 32 F The default value is 32...

Страница 15: ...F to 120 F The default value is 80 F Outdoor air shutdown differential The outdoor air shutdown differential parameter is the number of degrees below parameter F5 the outdoor air temperature must go...

Страница 16: ...an additional 10 seconds to clear the combustion chamber and vent system of residual flue products Service The unit has been placed in a temporary mode that will allow the unit to fire at 100 of rate...

Страница 17: ...e outdoor air sensor wires or the sensor itself has become grounded Press the Next arrow key on the SMART SYSTEM display to access Screen 4 4 FLUE F The control will display the flue temperature Open...

Страница 18: ...mote thermostat and has not powered the system pump ON The control has received a call for heat from a remote thermostat and has powered the system pump Delay The system call for heat has been satisfi...

Страница 19: ...User s Information Manual 19 5 Notes...

Страница 20: ...KB USER 01 09 05...

Отзывы: