background image

               

User’s Information Manual 

Please read before proceeding

3

 NOTICE

This is a gas appliance and should be 
installed by a licensed electrician and/or 
certified gas supplier.  Service must be 
performed by a qualified service installer, 
service agency or the gas supplier.

 WARNING

If the information in these instructions is 
not followed exactly, a fire or explosion 
may result causing property damage, 
personal injury, or death.

This appliance MUST NOT be installed in 
any location where gasoline or flammable 
vapors are likely to be present, unless 
the installation is such to eliminate the 
probable ignition of gasoline or flammable 
vapors.

What to do if you smell gas –

•  Do not try to light any appliance.

•  Do not touch any electric switch; do not 
  use any phone in your building.

•  Immediately call your gas supplier from 
 a near by phone.  Follow the gas 
 supplier’s instructions.

• If you cannot reach your gas supplier, 
  call the fire department.

Installation and service must be performed 
by a qualified installer, service agency, or 
the gas supplier.

Warranty –

Installation and service must be performed by a qualified 
service installer, service agency or the gas supplier.

Factory warranty (shipped with unit) does not apply to units 
improperly installed or improperly operated.

Experience has shown that improper installation or system 
design, rather than faulty equipment, is the cause of most 
operating problems.

1.  Excessive water hardness causing a lime/scale build-up in 
 

the copper tube is not the fault of the equipment and is 

  not covered under the manufacturer’s warranty 
 (see 

Water Treatment and Water Chemistry

).

2.  Excessive pitting and erosion on the inside of the copper 
 

tube may be caused by too much water velocity through 

 

the tubes and is not covered by the manufacturer’s 

 warranty 

(see 

Boiler Flow Rates and Temperature Rise for 

 flow 

requirements

).

Checking equipment –

Upon receiving equipment, check for signs of shipping 
damage. Pay particular attention to parts accompanying the 
appliances which may show signs of being hit or otherwise 
being mishandled. Verify total number of pieces shown on the 
packing slip with those actually received. In case there is damage 
or a shortage, immediately notify the carrier.

Do not use this appliance if any part has been under water.  
The possible damage to a flooded appliance can be extensive 
and present numerous safety hazards.  Any appliance that has 
been under water must be replaced.

 WARNING

Improper installation, adjustment, alteration, 
service or maintenance can result in severe 
personal injury, death, or substantial property 
damage.  Refer to this manual for assistance 
or additional information, consult a qualified 
installer, service agency or the gas supplier.

 Owner warning –

NOTE:

  Retain this manual for future reference.

The information contained in this manual is intended for use 
by qualified professional installers, service technicians, or gas 
suppliers.  

Consult your local expert for proper installation or 

service procedures.

 

IMPORTANT

Consult and follow all local Building and 
Fire Regulations and other Safety Codes 
that apply to this installation.  Consult your 
local gas utility company to authorize and 
inspect all gas and flue connections.

Your conventionally vented gas appliance must have a supply 
of fresh air circulating around it during burner operation for 
proper gas combustion and proper venting.  

 WARNING

Should overheating occur or the gas supply 
fail to shut off, do not turn off or disconnect 
the electrical supply to the pump.  Instead, 
shut off the gas supply at a location external 
to the appliance.

Содержание 000 BTU/HR

Страница 1: ...or flammable vapors are likely to be present WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electric switch do not use any phone in your building Immediately call your gas supplier from a near by phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified instal...

Страница 2: ...ndicates a potentially hazardous situation which if not avoided may result in property damage NOTICE indicates special instructions on installation operation or maintenance that are important but not related to personal injury or property damage Contents HAZARD DEFINITIONS 2 PLEASE READ BEFORE PROCEEDING 3 4 1 MAINTENANCE SCHEDULE 5 Maintenance Procedures 6 Appliance Must Be Serviced and Maintaine...

Страница 3: ...ed by too much water velocity through the tubes and is not covered by the manufacturer s warranty see Boiler Flow Rates and Temperature Rise for flow requirements Checking equipment Upon receiving equipment check for signs of shipping damage Pay particular attention to parts accompanying the appliances which may show signs of being hit or otherwise being mishandled Verify total number of pieces sh...

Страница 4: ...ll be installed in accordance with those installation regulations in force in the local area where the installation is to be made These regulations shall be carefully followed in all cases Authorities having jurisdiction shall be consulted before installations are made In the absence of such requirements the installation shall conform to the latest edition of the National Fuel Gas Code ANSI Z223 1...

Страница 5: ... tank Check control settings Check wiring and connections Flame inspection stable uniform Check flue gas passageways Inspect and clean the burners Perform start up check out and performance verification per Section 6 Startup of the Solution Installation and Service manual If combustion or performance indicate need Clean heat exchanger Remove and wash burners ANNUAL START UP Owner maintenance see p...

Страница 6: ...ontaining chlorine or fluorine if allowed to contaminate the appliance intake air will cause acidic condensate in the boiler This will cause significant damage to the boiler if allowed to continue WARNING Failure to inspect the vent system as noted above and have it repaired by a qualified service technician can result in vent system failure causing severe personal injury or death Check vent pipin...

Страница 7: ...Solution Installation and Service Manual The discharge line must be terminated so as to eliminate possibility of severe burns or property damage should the valve discharge 2 Read the boiler pressure temperature gauge to make sure the system is pressurized Lift the relief valve top lever slightly allowing water to relieve through the valve and discharge piping 3 If water flows freely release the le...

Страница 8: ...t has been under water must be replaced Operating Instructions 1 STOP Read the safety information first 2 Remove the control panel door 3 Set the thermostat to the lowest setting OFF 4 Turn off all electrical power to the appliance 5 This appliance is equipped with an ignition device which automatically lights the pilot DO NOT try to light the pilot by hand 6a 45 000 135 000 Btu hr models rotate t...

Страница 9: ...hermostat to highest setting 3 Turn electric power ON 4 Pump relay pulls in to start pump 5 The ignition will begin sparking at the pilot 6 The ignition module will lock out after the trial for ignition period 7 Immediately call a qualified serviceman or installer to repair an ignition system that fails to lock out and properly shut down burner operation 8 After successful completion of the test r...

Страница 10: ...10 NOTES ...

Страница 11: ...NOTES 11 ...

Страница 12: ...Revision Notes Revision A ECO C03746 initial release Revision B ECO C12077 reflects the update of ignition timing information on page 9 SBR USER Rev B 01 13 ...

Отзывы: