LOADRITE SPRINT OPERATORS MANUAL
15
Raise the empty bucket smoothly past the
trigger point. The Loadrite beeps and
performs the zero adjustment.
Z e ro
U p da te d
If Auto Add is not on, or Auto Add Time is not set to 0, follow the standard
procedure to zero (page 13).
Auto-Add is described on page 11.
Recalling Last Load
The Recall function is equivalent to lifting the same load again and can be
used to correct mistakes.
You can recall and display the last load if it has been:
•
Added
•
Subtracted, or
•
Timed out (ignored).
Recall function does not work when in ‘Static Weigh’ mode.
To correct a
mistake incurred when in ‘Static Weigh’ mode, re-weigh the load and then
subtract that amount. Refer to page 12 for subtracting a load.
To Recall the previously lifted weight
(Weights shown are examples only)
Current total 5600
Press
.
R e a d y
5600
The Loadrite beeps and displays the last
load.
(Weight of last load 2200)
T o t a l
5 6 0 0
2200