![Load Cell Systems WDESK-L Скачать руководство пользователя страница 48](http://html1.mh-extra.com/html/load-cell-systems/wdesk-l/wdesk-l_installation-and-user-manual_1932344048.webp)
- 43 -
NO PRODUCT LOAD TIME
(from 0.0 to 999.9 seconds; default: 0.0): this parameter allows the product control during
batching. if there is no product load, the instrument waits for a set duration of time before activating
the alarm
.
NO PRODUCT UNLOAD TIME
(from 0.0 to 999.9 seconds; default: 0.0): this parameter allows the product control during
the unloading phase (cycle end). If there is no product extraction, the instrument waits for a set
duration of time before activating the alarm
.
WARNING: The control is only actuated after unloading of the product has started (the weight must
decrease by at least 10 divisions).
FALL
By FALL it means the correction of the product amount in fall after the batching STOP. This amount
is in addition to the product already batched causing inaccuracy. The instrument is able to anticipate
the batching STOP, to reduce this uncertainty, with two possible ways:
-
AUTOMATIC fall: the instrument automatically calculates the fall;
-
MANUAL fall: the instrument applies the fall set by the operator;
WARNING: Setting a value of WAITING TIME (
) such that the weight is stable at the end of
the batching, otherwise the update of the AUTOMATIC fall is not correct.
(from 0 to 1; default: 0): it’s possible to select the automatic or the manual fall.
-
= 0: MANUAL fall
-
= 1: AUTOMATIC fall
(from 0 to maximum weight; default: 0): in this parameter it is possible to set the fall value for
each product (only if
= 0) or to display and/or to modify the fall value calculated
automatically by the instrument (only if
= 1).
TOLERANCE
(from 0 to maximum weight; default: 0): Adjustable parameter for each product that defines how
much the batched weight value can deviate from the one set in formula. If the batched weight is
higher or lower than the amount to be batched, for a value greater than the tolerance, the instrument
closes the ALARM contact. Press ENTER to continue the batching. Example: if a PRODUCT = 1000
value is set and a TOLERANCE = 100 value is set, the batched weight must not be lower than 900
or higher than 1100
to allow the instrument to continue the batching process. By setting 0, the
function is disabled.