background image

Cleaning and Maintenance

23

Fireplace Owner’s Manual

LTR50001006, Rev. E

www.calflamebbq.com

 Replacement Parts

Call 

1-800-225-7727 

for any replacement parts not listed below. Be 

sure to have model name and number available.

Replacement parts shown below are listed fi rst as complete assemblies 

with individual parts that can be ordered separately.

Fiberglass fi rebox assembly 36” set of 5 pieces

BBQ08210622

Left panel for 36” fi rebox, 22 7/8” x 20 7/8”

BBQ08216023

Right panel for 36 fi rebox, 22 7/8” x 20 7/8”

BBQ08210624

Back panel for 36” fi rebox, 28.25” x 34.5”

BBQ08210625

Base panel for 36” fi rebox, 21” x 35 3/4”

BBQ08210626

Arch for 36” fi rebox, 45” x 37”

BBQ08210627

Metal fi rebox assembly 36” set of 2 pieces

BBQ08210583

Housing for 36” metal fi rebox

BBQ08210580

Top for 36” metal fi rebox

BBQ08210581

Fireplace log set 24” 7 pieces

BBQ08000620

Fireplace log grate 18”

BBQ08210650

Fireplace burner valve assembly, with lava rock, 3/8” 

x 108” hose and propane regulator

BBQ07210012

Fireplace rectangle burner assembly set of 4 pieces

BBQ04100076

Rectangle burner body 7.25” x 14.25” stainless 

steel

BBQ04100089

Orifi ce NG .125 1/4” fl are

BBQ04100077

Orifi ce LP #43 1/4” fl are

BBQ04100078

Flare fi tting 3/8” male fl are, 1/4” female fl are

BBQ04103047

Содержание Cal Flame

Страница 1: ...LTR50001006 Rev E 1 1 16...

Страница 2: ...ireplace Burner Installation 13 Fireplace Log Set Placement 16 High Elevation Installation 17 Natural Gas Conversion 17 Operation 19 Cleaning and Maintenance 22 Replacement Parts 23 Specifications 24...

Страница 3: ...cause in jury or property damage Read the installation operating and maintenance instructions thoroughly be fore installing or servicing this equipment Cal Flame fireplaces are designed for outdoor us...

Страница 4: ...rs do not allow them to come in contact with any metal surfaces Do not drop propane connectors Propane gas sources to the fireplace must be regulated Do not operate if regulator has been removed Fire...

Страница 5: ...e the control compartment burner and circulation air passage ways of the appliance be kept clean and free Any guard or other protective device removed for servicing the ap pliance must be replaced pri...

Страница 6: ...gs tightly installed and must not be stored in a building garage or any other enclosed area To extend the life of your fireplace protect and cover it from the elements when not in use Ensure the appli...

Страница 7: ...applicable To prevent fire and smoke damage remove all packaging material be fore operating the fireplace Installation Assembly Installation and service must be performed by a quali fied installer ser...

Страница 8: ...ireplace as gas may build up in case of leak and cause serious damage Do not install or operate your fireplace in such a manner that the cross ventilation openings are blocked Fresh air must be able t...

Страница 9: ...as 3 On natural gas systems turn the main feed valve to the burner On propane systems turn the cylinder valve knob counter clock wise one turn to open Apply the leak testing solution by spraying it on...

Страница 10: ...uniform gas pressure in the manifold The burner orifice has been sized for the gas pressure delivered by the regulator Replace ment pressure regulator and hose assemblies must be those specified in th...

Страница 11: ...n off gas valve at the end of the hose Tighten fittings using two wrenches When connecting the regulator assembly to the tank valve hand tight en the black QCC 1 nut clockwise DO NOT use a wrench to t...

Страница 12: ...nder valves are always readily accessible A door on the en closure to gain access to the cylinder valve is acceptable provided it is non locking and can be opened without the use of tools Enclosures f...

Страница 13: ...oor level with a total free area of inch per pound 3 2 sq cm k of stored fuel capacity and not less than a total free area of 10 square inches if the ventilation open ings at oor level are in a side...

Страница 14: ...st be performed by a licensed con tractor or local gas company representative Ensure that the service supplying the fireplace is fitted with a conve niently positioned shut off valve with easy access...

Страница 15: ...ocedure describes how to access the gas lines for installation Gas installation should be performed by a qualified contractor Remove the right side refractory wall from the fireplace by remov 2 ing on...

Страница 16: ...ack sparker 6 wires to the valve as shown Reach through the gap in the 5 open right side and pull the ex line and black sparker wires Connect the ex line from the 7 burner to the gas valve as shown be...

Страница 17: ...alflamebbq com Caution Never place or store the propane tank under the hearth base Connect the LP or NG gas 9 source gas line to the gas valve as shown below Replace the right side refrac 10 tory wall...

Страница 18: ...ate over the plate burner Place the lava rock around the at burner plate DO NOT place the lava rock on the burner plate as it will affect the ow of the ame Place the ceramic fire logs on the grate Sta...

Страница 19: ...iance installer Do not attempt this conversion on your own as there is risk of serious injury or death To The Authorized Gas Appliance Installer All Cal Flame fireplaces are shipped from the factory e...

Страница 20: ...finally the natural gas orifice is to be threaded into the end of the fuel inlet leading into the burner Once tight the other brass fitting connection can be made from the fuel line fitted between the...

Страница 21: ...such purging Never allow the ON OFF valve to remain in the open position without placing a burning match on top of the burner FIRST You must have clear and easy access to the ON OFF valve AFTER the ap...

Страница 22: ...pping noise Keep igniter button pushed in while slowly turning the fuel ow valve to the full ow position at the fireplace The fireplace should light within 5 seconds If you do not hear the igniter spa...

Страница 23: ...nce is equipped with a low ow protection device Unless the propane cylinder valve is opened before the valve the gas ow will be reduced resulting in a very small ame To reset this device shut off the...

Страница 24: ...he surfaces of the logs with heavy use This is more likely to occur with propane gas Clean soot off the surface of the logs periodically to prevent excessive buildup To clean the logs be sure the fire...

Страница 25: ...8210624 Back panel for 36 firebox 28 25 x 34 5 BBQ08210625 Base panel for 36 firebox 21 x 35 3 4 BBQ08210626 Arch for 36 firebox 45 x 37 BBQ08210627 Metal firebox assembly 36 set of 2 pieces BBQ082105...

Страница 26: ...Natural Gas Max Input BTU Hr 55 000 49 000 Orifice Size 43 0 089 1 8 125 Manifold Pressure 10 Water Column 7 Water Column Maximum Gas Supply Pressure 11 Water Column 14 Water Column Maximum Inlet Supp...

Страница 27: ...ervice technician Depending on your needs this may be a contractor qualified to repair stone and tile or a service agent licensed to repair gas or electrical appliances In the event the consumer is un...

Страница 28: ...t apply to labor charges replacement parts and hard ware This limitation is retroactive and applies to all fireplaces and hardware manufactured from 2000 and hereafter Examples of common acts invalida...

Страница 29: ...t considered defects Legal Remedies This limited warranty gives you specific legal rights You may have other rights which may vary from state to state Customer Service For customer service contact the...

Страница 30: ...28 Limited Warranty Fireplace Owner s Manual LTR50001006 Rev E www calflamebbq com...

Страница 31: ...Limited Warranty 29 Fireplace Owner s Manual LTR50001006 Rev E www calflamebbq com...

Страница 32: ...ice please contact your authorized dealer immediately If you need additional information and or assistance please contact Cal Flame Customer Service Department 1462 East Ninth Street Pomona CA 91766 T...

Отзывы: