Installation /
Assemb
ly
9
Fireplace Owner’s Manual
LTR50001006, Rev. E
www.calflamebbq.com
Connection
Check the rating plate to make sure the gas supply you are hooking up
to is the gas type the fi replace is manufactured for.
Inspect the hose shipped with the unit for damage. Never attempt to
use damaged or plugged equipment. See your local liquid propane gas
dealer for repairs. After inspecting the propane hose shipped with the
unit, connect the end with the female fi tting on the hose to the male
fi tting on the on/off gas valve at the end of the hose. Tighten fi ttings
using two wrenches.
When connecting the regulator assembly to the tank valve, hand tight-
en the black QCC-1 nut clockwise. DO NOT use a wrench to tighten.
See the fi gure below.
Purge the gas supply line of any trapped air prior to the fi rst fi ring of
the unit.
During the initial purging and subsequent lightings, NEVER allow gas
to remain in the “Open” position without fi rst placing and igniting the
fi re starter.
Be certain to mount or set the 20 lb propane gas cylinder on a fl at
surface and restrain it to prevent it from tipping.
Locate the hose out of the pathways where people may trip over it or in
areas where the hose may be subjected to accidental damage.