20
Instruction Manual
SECTION 3 - OPERATION
3.4.1.3.3 Analog Mode (for AD8)
The pump is in Analog Mode when ‘mA’ is shown
on the left-hand side of the LCD Display.
Pressing the Up or Down Button will display ‘P1’
and the milliamp input that corresponds to zero
strokes. The Up and Down Buttons can be used
to adjust this value. Pressing the Power Button
(or waiting for about 8 seconds) will display ‘P2’
and the milliamp input that corresponds to max
stroke rate. Note that the maximum stroke rate
will be either 120 strokes per minute or 59 strokes
per hour. This depends on the stroke speed set in
Internal Mode.