G-WHIZ 

 

 

 
 

User Manual 

For G-WHIZ Firmware 8.00 and greater 

 
 
 
 

Содержание G-WHIZ

Страница 1: ...Dr Fenton MI 48430 Ph 810 714 5811 Fax 810 714 5711 CustomerService lmicorporation com Research Development and Manufacturing of Precision Measuring Systems G WHIZ User Manual For G WHIZ Firmware 8 00...

Страница 2: ...he LMI G WHIZ 9 3 2 Factory Default Models 10 3 3 Charging the LMI G WHIZ 10 Battery Type and Life 10 G WHIZ Single Gage In Line Charger 10 3 4 Mastering 11 SECTION 4 WIRELESS UTILITY SOFTWARE 12 4 1...

Страница 3: ...NG THE G WHIZ 26 5 1 Attaching to the Vehicle 26 5 2 Starting and Performing a Test 27 5 3 G Whiz Key Functions 28 5 4 Invalid Tests and Buffer Full Messages 28 5 5 LMI G Whiz Part Replacement 29 ADDE...

Страница 4: ...or your records No other express warranty is given The repair or replacement of a product is your exclusive remedy Any implied warranty of merchantability or fitness is limited to the 1 year duration...

Страница 5: ...LMI equipment To help implement data collection applications To troubleshoot LMI equipment You and also reach LMI Technical Support By Email at 0Htechsupport lmicorporation com You can email your ques...

Страница 6: ...analysis and tracking There are three methods to utilize the G WHIZ Closing Effort device Standalone This method allows the operator to instantly view readings from the display on the gauge Simply gr...

Страница 7: ...options and RETAKE information LED The LED will flash red to indicate that the gauge is waiting for a test to begin The LED is also used to indicate when the gauge is in the SETUP mode In this mode t...

Страница 8: ...shed The red line on the plunger should not be visible 4 Open the door to the first detent Press the center button to start the test When the green LED turns on push the door closed with a fluid motio...

Страница 9: ...button The screen will look like the following Press the Down and Up buttons to navigate the menu Push the Center button to enter a choice SELECT MODEL Allows the operator to select one of ten user de...

Страница 10: ...go vans and semis Sample time of 2 5 sec MD9 SLDR SLDR 100 Hz Vclosing Slider enabled Reports velocity of the push at a 100 Hz sample rate on a sliding door 10mm from the latch position Sample time of...

Страница 11: ...factory There is no need for the user to perform calibration on the G WHIZ This calibration is stored in the microprocessor of the gauge even if batteries are removed or replaced Calibration of axes...

Страница 12: ...gages edit and save gage parameters and edit model information The software will allow users to load custom configurations view live readings and adjust gauge parameters for each of the ten models wit...

Страница 13: ...ware or any portion thereof in any form on the Internet You may not use the Software in a computer service business including in time sharing applications The Software contains trade secrets and in or...

Страница 14: ...restricted rights as follows If the Software is acquired under the terms of a GSA contract use reproduction or disclosure is subject to the restrictions set forth in the applicable ADP Schedule contra...

Страница 15: ...P Windows 7 32 Bit 64 Bit Screen Resolution 1024x768 Memory needed 1GB Processor Speed needed Intel i3 Serial COM Port 1 1 COM Port LMI System 1 USB 2 0 Port Recommended Computer Specifications Operat...

Страница 16: ...t ships with each USB base Also note that the Microsoft NET framework must be installed in order for Wireless Utility to be installed Most modern PCs have this included however if your computer does n...

Страница 17: ...alibration Instructions G WHIZ CA 183 LMI G WHIZ User Guide doc Page 17 of 35 Choose the folder you wish to install this program into on your PC The Default location is recommended Click on Next at th...

Страница 18: ...3 5 1 2017 R Quality Calibration Instructions G WHIZ CA 183 LMI G WHIZ User Guide doc Page 18 of 35 Click on Next Button at the bottom Window showing status of install will appear next When the instal...

Страница 19: ...age with two 2 tabs The first tab is the default Wireless Base tab that will list all information from the Wireless Base Device You should see a message in a green box at the bottom of the window that...

Страница 20: ...eCollect USB base unit and LMI s UGI software both sold separately in order to communicate properly with your software package In order to do this the gauge s must be placed into Set Up mode first see...

Страница 21: ...ge Model will appear in the grid with the current G WHIZ information listed If it does not appear within the grid make sure the gauge is in set up mode and repeat the listed steps above The grid will...

Страница 22: ...n window will appear once the changes have been received by the gauge and the Edit Gauge window has been closed If changes are made to the doors models in the grid below the blue Gauge Configurations...

Страница 23: ...Allows the user to choose between the measurement algorithms for Velocity Force or Work Time Out min Amount of time a G WHIZ gauge can be left unattended in set up mode before automatically exiting se...

Страница 24: ...lected at 100 Hz sample rate Velocity at a set distance from latch is returned 800 Hz Peak 1600 Hz Peak and 3200 Hz Peak are for door pop off testing Please consult Addendum E for information on pop o...

Страница 25: ...ed for a future release Load Defaults Loads the factory default model settings into the G WHIZ Load Models Loads the models currently on the G WHIZ into the Wireless Utility Update Models Loads the mo...

Страница 26: ...s down against the panel and the red band on the plunger disappears The narrow sealing ring surface on the contact side of the vacuum cup needs to be kept clean and free of cuts and gouges Any imperfe...

Страница 27: ...is time give the door a crisp firm push to close it Be sure your hand comes off the door before the door starts to engage the latch The velocity in meters per second this is the default will appear on...

Страница 28: ...un The primary reason for this message is that the operator begin to close the door before the READY message appeared The G WHIZ has buffer times based on the sampling rates of 400 HZ 200 HZ and 100 H...

Страница 29: ...s or use new screws provided with the end covers Do not turn the screws all the way down until they tighten to the black plastic casing below Just run the screw down into the counter bored holes in th...

Страница 30: ...cing remove the 7 16 hex nut securing the vacuum cup to the mounting bracket The vacuum cup comes standard with an alignment pin to keep it from turning in the device Notice there are two holes if you...

Страница 31: ...o view a graphic representation of the last push taken with the G WHIZ you can download the Velocity Distance and or Acceleration Curves from the Edit Gages screen of Wireless Utility Note the G WHIZ...

Страница 32: ...the lower right hand corner of the window Note Downloading the Acceleration curve deletes the data from the G WHIZ To get both curves be sure to always download the Velocity curve and or data before...

Страница 33: ...tions on page 18 Double click the appropriate Gauge Model in the grid to bring up the Edit Gauges page Uncheck the Send Desc with Reading box in the Gauge Configurations panel to put the G WHIZ in DM6...

Страница 34: ...or the model you will be testing Update the models within the G WHIZ and close out Wireless Utility Select the 800 Hz VPeak model in the G WHIZ 2 The red LED on the G WHIZ should be blinking Press and...

Страница 35: ...data into ComTestSerial 6 Excluding the zeroes 0 00 in the list copy and paste this data into an Excel spreadsheet 7 With the data still highlighted click on the INSERT tab in Excel and click on the I...

Отзывы: