PRECAUTIONS 

 

1.0 Precautions 

The following precautions should be taken when working with LMI metering pumps. 

Please read this section carefully prior to installation. 

Protective Clothing

 

 

 

ALWAYS wear protective clothing, face shield, safety glasses and gloves when working on or 

near your metering pump. Additional precautions should be taken depending on the solution 

being pumped. Refer to Safety Data Sheets (SDS) precautions from your solution supplier. 

Water Pre-Prime

 

 

 

All LMI pumps are pre-primed with water when shipped from the factory. If your solution is not 

compatible with water, disassemble the Pump Head Assembly. Thoroughly dry the pump head, 

valves, O-rings, balls and diaphragm. Reassemble head assembly tightening screws in a 

crisscross pattern. Refill the pump head with the solution to be pumped before priming the 

pump. (This will aid in priming.) 

Liquid Compatibility

 

 

 

CAUTION: The evaluation performed by ETL was tested with water only. The pumps are 

certified to NSF 61 with: sodium hypochlorite (12.5%), sulfuric acid (98.5%), sodium hydroxide 

(50%), and hydrochloric acid (30%). Determine if the materials of construction included in the 

liquid handling portion of your pump are adequate for the solution (chemical) to be pumped. 

Always refer to the solution supplier and the LMI Chemical Resistance Chart for compatibility of 

your specific LMI metering pump. Contact your local LMI distributor for further information. 

Tubing Connections

 

 

 

Inlet and outlet tubing or pipe sizes must not be reduced. Outlet tubing size must not be 

increased. Make certain that all tubing is SECURELY ATTACHED to fittings prior to start-up (see 

section 3.3 Tubing Connections). ALWAYS use LMI supplied tubing with your pump, as the 

tubing is specifically designed for use with the pump fittings. It is recommended that all tubing be 

shielded and secure to prevent possible injury in case of rupture or accidental damage. If tubing 

is exposed to sunlight, black UV resistant tubing should be installed. Check tubing frequently for 

cracks and replace as necessary. 

Fittings and Machine Threads

 

 

 

All fittings should be hand-tightened. An additional 1/8 - 1/4 turn after the fitting is snug may be 

necessary to provide a leak-proof seal. Excessive overtightening or use of a pipe wrench can 

cause damage to the fittings, seals, or pump head. 
Most LMI pumps have straight screw machine threads on the head and fittings and are sealed 

by the O-rings. DO NOT use PTFE tape or pipe dope to seal these threads. PTFE Tape may 

only be used on NPT threads. 

Plumbing

 

 

 

Always adhere to your local plumbing codes and requirements. Be sure installation does not 

constitute a cross connection. Check local plumbing codes for guidelines. LMI is not responsible 

for improper installations. 

 

 

 

Содержание Excel XR Series

Страница 1: ...el XR Series Electronic Metering Pump PROFIBUS DP V0 Manual Manual No 55313 Revision 04 Rev Date 03 2020 Note For enhanced control features see manual 54630 and enhanced control features see manual 54...

Страница 2: ...24 Operation Mode Configuration 9 4 1 3 Modules 26 42 Timed Event Configuration 10 4 1 4 Modules 43 57 Input Output Configuration 11 4 1 5 Modules 58 64 System Settings 12 4 1 6 Modules 65 68 Read Onl...

Страница 3: ...the LMI Chemical Resistance Chart for compatibility of your specific LMI metering pump Contact your local LMI distributor for further information Tubing Connections Inlet and outlet tubing or pipe si...

Страница 4: ...annot occur Ground Fault Circuit Interrupter WARNING To reduce the risk of electric shock install only on a circuit protected by a Ground Fault Circuit Interrupter GFCI Line Depressurization To reduce...

Страница 5: ...y a global network of highly trained field engineers and aftersales support The PROFIBUS DP interface conforms to the PROFIBUS DP V0 standard for cyclic data transmission This manual assumes the reade...

Страница 6: ...display screen indicates there are more settings available on another page Figure 1 Display Navigation 3 2 Settings To access the settings screen Figure 2 press Settings in the home screen Navigate to...

Страница 7: ...an be configured via software in the range of 1 125 The Internal Line Termination can also be enabled disabled on this screen The final device on the communication bus must have line termination enabl...

Страница 8: ...associated operation mode Bit 0 Manual Local only Bit 1 Analog External Bit 2 Pulse External Bit 3 Batch External Bit 4 Cycle Timer Internal Bit 5 Timed Event Internal Input Output UINT8 2 Manual Flo...

Страница 9: ...put Output UINT8 13 Batch Mode Volume XXXXX XX mL The valid range is 0 to 1000000 Input Output UINT32 14 Batch Mode Time Seconds Range is 1 86400 Input Output UINT32 15 Batch Mode Units Enumeration 0...

Страница 10: ...31 Timed Event2 Start Time 4 decimal digit format HHMM Range HH Hour 00 23 MM Minute 00 59 Input Output UINT16 32 Timed Event2 Duration Integer representing minutes with a valid range of 1 1439 Input...

Страница 11: ...Input 3 Config Enumeration with a range 0 5 The enumeration is as follows 0 Digital Input Disabled 1 Digital Input RemoteOnOff 2 Digital Input FloatSwitch_Empty 3 Digital Input FloatSwitch_Low 4 Digi...

Страница 12: ...4 Digital Output AlarmOut 5 Digital Output INTEXTMode 6 Digital Output UserAlarmOut 7 Digital Output PumpStopped 8 Digital Output TimedEvent Input Output UINT8 56 Digital Output 2 State Enumeration 0...

Страница 13: ...1 6 Modules 65 68 Read Only Version Information Module Name Description Direction Data Type 65 Main Firmware Version Range is 0 65535 as an integer that must be converted to hex to be read as 0000 FFF...

Страница 14: ...ut UINT32 78 Totalizer User Volume Integer representing Gal or L depending on current unit setting Output UINT64 79 Totalizer User Hours Integer representing number of hours Output UINT32 80 Totalizer...

Страница 15: ...t 7 Current Units 0 English 1 Metric Bit 8 Pump Calibration Status 0 No 1 Yes Bit 9 Keypad Locked Status 0 No 1 Yes Bit 10 Home Screen Displayed 0 No 1 Yes Bit 11 Batch Mode Dosing Active 0 No 1 Yes B...

Страница 16: ...12 B Code connector with the following pin out Figure 5 Connector C Pin Diagram The M12 circular connector conforms to IEC 60947 5 2 or IEC 61076 2 101 per the PROFIBUS Interconnection Technology Guid...

Страница 17: ...CABLE WIRING...

Страница 18: ...correct Wiring 3 Verify wiring is correct per Figure 5 Connector C Pin Diagram 4 Pump not powered 4 Verify the pump is powered on Pump does not start when commanded via PROFIBUS 1 Homescreen is not di...

Страница 19: ...nd specialty vehicle products and services across 40 respected brands designed to excel in even the most complex and harsh conditions where downtime is especially costly Our employees connect to custo...

Отзывы: