PROFIBUS SOFTWARE DEFINITION
4.1.4 Modules 43-57: Input/Output Configuration
Module Name
Description
Direction
Data
Type
43
Digital Input 1
Config
Enumeration with a range 0-5. The
enumeration is as follows:
0: Digital Input = Disabled
1: Digital Input = RemoteOnOff
2: Digital Input = FloatSwitch_Empty
3: Digital Input = FloatSwitch_Low
4: Digital Input = RemoteIntExtMode
5: Digital Input = PacingPulse
Input/Output UINT8
44
Digital Input 1
State
Enumeration (0=NO - Normally Open, 1=NC
- Normally Closed).
Input/Output BOOL
45
Digital Input 2
Config
Enumeration with a range 0-5. The
enumeration is as follows:
0: Digital Input = Disabled
1: Digital Input = RemoteOnOff
2: Digital Input = FloatSwitch_Empty
3: Digital Input = FloatSwitch_Low
4: Digital Input = RemoteIntExtMode
5: Digital Input = PacingPulse
Input/Output UINT8
46
Digital Input 2
State
Enumeration (0=NO - Normally Open, 1=NC
- Normally Closed).
Input/Output BOOL
47
Digital Input 3
Config
Enumeration with a range 0-5. The
enumeration is as follows:
0: Digital Input = Disabled
1: Digital Input = RemoteOnOff
2: Digital Input = FloatSwitch_Empty
3: Digital Input = FloatSwitch_Low
4: Digital Input = RemoteIntExtMode
5: Digital Input = PacingPulse
Input/Output UINT8
48
Digital Input 3
State
Enumeration (0=NO - Normally Open, 1=NC
- Normally Closed).
Input/Output BOOL
49
Digital Input 4
Config
Enumeration with a range 0-5. The
enumeration is as follows:
0: Digital Input = Disabled
1: Digital Input = RemoteOnOff
2: Digital Input = FloatSwitch_Empty
3: Digital Input = FloatSwitch_Low
4: Digital Input = RemoteIntExtMode
5: Digital Input = PacingPulse
Input/Output UINT8
50
Digital Input 4
State
Enumeration (0=NO - Normally Open, 1=NC
- Normally Closed).
Input/Output BOOL
51
Analog Input 1
Config
Enumeration with a range 0-2. The
enumeration is as follows:
0: Analog Input = Disabled
1: Analog Input = Pacing
2: Analog Input = Level
Input/Output UINT8
52
Analog Input 2
Config
Enumeration with a range 0-2. The
enumeration is as follows:
0: Analog Input = Disabled
1: Analog Input = Pacing
2: Analog Input = Level
Input/Output UINT8