The ‘hr : min’ will change to ‘min : sec’ automatically as the run time is reduced below one (1) hour.
Delay Timers are factory set in the deactivated mode.
The ‘Delay 1 and Delay 2’ Timers are activated/deactivated
in the ‘Advanced Features Menu.’ These screens will not display when the delay option is deactivated.
(1) ...... Press the
key to view the run time for ‘Pump A’.
(2) ...... Use
to adjust to desired maximum run time.
The ‘hr : min’ will change to ‘min : sec’ automatically as the run time is reduced below one (1) hour.
(3) ...... Press the
key to advance to run time for ‘Pump B’.
(4) ...... Use
to adjust to desired maximum run time.
Solenoid Valve Control:
(5) ...... Press the
key to advance to ‘Delay 1’ time (if
activated). ‘Delay 1’ is the wait time after pH enters the
desired region, before the Solenoid is activated.
(6) ...... Press the
key to advance to ‘Delay 2’ time (if
activated). ‘Delay 2’ is the Solenoid ‘ON’ time.
If the pH should go out of the desired range during ‘Delay1’ or ‘Delay 2’, the Solenoid cycle will terminate.
It will start again from zero when pH re-enters the desired region. If pH remains in the desired region, the controller
will enter ‘OFF’ mode at the end of the Solenoid ‘ON’ time. The controller turns ‘ON’, again in one minute and the
cycle repeats.
Setting Timers:
The unit must be in the ‘OFF’ (edit) mode to change the timer settings.
For proportional mode pump run time must be set above 11 HR 01 Min to ensure continuous operation.