Gocator Line Profile Sensors - User Manual
Gocator Web Interface • Measurement • 156
4.
Click on the
Output
tab.
For some measurements, only the
Output
tab is displayed.
5.
Enter values in the
Min
and
Max
fields.
Filters
Filters can be applied to measurement values before they are output from the Gocator sensors.
All measurements provide filter settings under the
Output
tab.
Filter
Description
Scale and Offset
The Scale and Offset settings are applied to the measurement value according to the
following formula:
Scale * Value + Offset
Scale
and
Offset
can be used to transform the output without the need to write a script. For
example, to convert the measurement value from millimeters to thousands of an inch, set
Scale
to 39.37. To convert from radius to diameter, set
Scale
to 2.
Hold Last Valid
Holds the last valid value when the measurement is invalid. Measurement is invalid if there
is no valid value.
Smoothing
Applies moving window averaging to reduce random noise in a measurement output. The
averaging window is configured in number of frames.
If
Hold Last Valid
is enabled, smoothing uses the output of the
Hold Last Valid
filter.
To configure the filters:
1.
Go to the
Measure
page by clicking on the
Measure
icon.
The
must be set to the type of measurement you need to configure.
Otherwise, the wrong tools, or no tools, will be listed on the
Measure
page.
2.
In the
Tools
panel, click on a tool in the tool list.
3.
In the measurement list, select a measurement.
To select a measurement, it must be enabled. See
Enabling and Disabling Measurements
for instructions on how to enable a measurement.
Содержание Gocator 2100 Series
Страница 10: ...Gocator Line Profile Sensors User Manual 10 Return Policy 515 Software Licenses 516 Support 522 Contact 523 ...
Страница 193: ...Gocator Line Profile Sensors User Manual Gocator Web Interface Measurement 193 2D View 3D View Measurement Panel ...
Страница 197: ...Gocator Line Profile Sensors User Manual Gocator Web Interface Measurement 197 ...
Страница 209: ...Gocator Line Profile Sensors User Manual Gocator Web Interface Measurement 209 2D View 3D View ...
Страница 214: ...Gocator Line Profile Sensors User Manual Gocator Web Interface Measurement 214 2D View 3D View ...
Страница 215: ...Gocator Line Profile Sensors User Manual Gocator Web Interface Measurement 215 ...
Страница 225: ...Gocator Line Profile Sensors User Manual Gocator Web Interface Measurement 225 2D View 3D View ...
Страница 462: ...Gocator Line Profile Sensors User Manual Specifications Sensors 462 Dimensions Envelope ...
Страница 464: ...Gocator Line Profile Sensors User Manual Specifications Sensors 464 Envelope ...
Страница 466: ...Gocator Line Profile Sensors User Manual Specifications Sensors 466 Dimensions Envelope ...
Страница 468: ...Gocator Line Profile Sensors User Manual Specifications Sensors 468 Dimensions Envelope ...
Страница 470: ...Gocator Line Profile Sensors User Manual Specifications Sensors 470 Dimensions ...
Страница 471: ...Gocator Line Profile Sensors User Manual Specifications Sensors 471 Envelope ...
Страница 473: ...Gocator Line Profile Sensors User Manual Specifications Sensors 473 Dimensions ...
Страница 474: ...Gocator Line Profile Sensors User Manual Specifications Sensors 474 Envelope ...
Страница 476: ...Gocator Line Profile Sensors User Manual Specifications Sensors 476 Dimensions ...
Страница 477: ...Gocator Line Profile Sensors User Manual Specifications Sensors 477 Envelope ...
Страница 479: ...Gocator Line Profile Sensors User Manual Specifications Sensors 479 Dimensions ...
Страница 480: ...Gocator Line Profile Sensors User Manual Specifications Sensors 480 Envelope ...
Страница 484: ...Gocator Line Profile Sensors User Manual Specifications Sensors 484 Dimensions ...
Страница 485: ...Gocator Line Profile Sensors User Manual Specifications Sensors 485 Envelope ...
Страница 487: ...Gocator Line Profile Sensors User Manual Specifications Sensors 487 Dimensions ...
Страница 488: ...Gocator Line Profile Sensors User Manual Specifications Sensors 488 Envelope ...
Страница 491: ...Gocator Line Profile Sensors User Manual Specifications Sensors 491 Dimensions ...
Страница 492: ...Gocator Line Profile Sensors User Manual Specifications Sensors 492 Envelope ...
Страница 506: ...Gocator Line Profile Sensors User Manual Specifications Master Hubs 506 Master 810 Dimensions ...
Страница 512: ...Gocator Line Profile Sensors User Manual Specifications Master Hubs 512 Master 2410 Dimensions ...