When you change sensor settings using the Gocator web interface, some changes are saved
automatically, while other changes are temporary until you take action to save them. The following table
summarizes the types of information that can be saved in a sensor.
Saved Information
Information Type
Behavior
Network Address
Network address changes are saved when you click the Save button in Main panel on
the Connection Page. The sensor must be reset before changes take effect.
Configuration
Most of the settings that can be changed in the Gocator’s web interface, such as
those shown on Setup, Measurement, and Output pages, are temporary until saved
in a configuration file. Each sensor can have multiple configuration files. If there is
a configuration file that is designated as the default, it will be loaded automatically
when the sensor is reset.
Calibration
Calibration files, described in Calibration (page 77), are saved automatically at the
end of the calibration procedure.
The sensor contains a global calibration file that is hidden from the user and not
visible in the file manager. This file will automatically be loaded when the sensor is
reset.
Configurations can be associated with specific calibration files, which are created by
selecting Current Configuration as the source when calibrating the Gocator (page
). These files are visible in the file manager and can be handled manually there.
Associated files have the same file name (but a different extension). If there is a
configuration file that is designated as default and it has an associated calibration
file, that calibration will be loaded automatically when the sensor is reset.
Each sensor can have only one global calibration file. But a sensor can contain many calibrations
associated with specific configurations. The number of files is limited only by the sensor’s flash storage
capacity. The Gocator’s web interface provides toolbar commands to load and save these files as a
bundle
.
Gocator can be set up to operate with a global calibration or with a calibration associated with
a specific configuration (see page 78). An associated calibration file is only included in the
file bundle if Current Configuration is currently selected as the calibration source.
FILE NAME
SAVE
LOAD
DELETE
The File Name drop down list shows the list of file bundles stored in the sensor. The configuration
that is currently loaded will be listed at the top. The name will be marked with an asterisk if the live
configuration is different from the loaded configuration to indicate unsaved changes.
To save a new bundle of files:
1
Select [New] in the File Name drop list.
2
Enteranameforthefilebundle.
3
Press the Enter key or click the Save button.
The configuration and the template will be saved to flash memory using the name provided. The saved
files will be set as the defaults to be loaded automatically when the sensor is reset.
Содержание Gocator 1100 Series
Страница 1: ...USER MANUAL Gocator 1100 1300 Series Version 3 6 5 15 Revision C...
Страница 187: ...Specifications 187 Gocator 1100 1300 Series Envelope 21 0 40 0 20 0 71 0 2 1 19 3 101 4...
Страница 189: ...Specifications 189 Gocator 1100 1300 Series Envelope 0 39 0 87 5 120 7 0 1 2 11 4 40 0 60 0...
Страница 191: ...Specifications 191 Gocator 1100 1300 Series Envelope 21 0 182 5 35 0 72 2 102 8 2 8 19 6...
Страница 193: ...Specifications 193 Gocator 1100 1300 Series Envelope 0 39 0 88 9 122 2 0 11 8 1 6 182 5 217 5...
Страница 196: ...Specifications 196 Gocator 1100 1300 Series Envelope 21 0 200 0 200 0 72 3 103 1 2 8 19 7...
Страница 199: ...Specifications 199 Gocator 1100 1300 Series Envelope 0 39 0 88 9 122 6 0 12 0 1 6 200 0 400 0...
Страница 202: ...Specifications 202 Gocator 1100 1300 Series Envelope 21 0 237 5 325 0 72 3 103 2 2 8 19 8...
Страница 205: ...Specifications 205 Gocator 1100 1300 Series Envelope 0 39 0 89 0 122 7 0 12 0 1 7 237 5 562 5...
Страница 208: ...Specifications 208 Gocator 1100 1300 Series Envelope 21 0 375 0 562 5 72 6 103 3 3 0 19 9...
Страница 211: ...Specifications 211 Gocator 1100 1300 Series Envelope 0 39 0 89 0 122 7 0 12 0 1 7 237 5 562 5...
Страница 214: ...Specifications 214 Gocator 1100 1300 Series Envelope 400 0 21 0 250 0 72 4 103 3 2 8 19 8...
Страница 217: ...Specifications 217 Gocator 1100 1300 Series Envelope 0 39 0 89 0 122 7 0 12 0 1 7 250 0 650 0...
Страница 220: ...Specifications 220 Gocator 1100 1300 Series Envelope 21 0 500 0 2000 0 200 1 231 4 2 7 19 9...
Страница 223: ...Specifications 223 Gocator 1100 1300 Series Envelope 0 12 0 1 6 500 0 2500 0 0 39 0 215 8 249 8...