LNGS.465213.270-10 OM
Page 9
An operating schedule: continuous, round the clock
Overall dimension: not more than 150*110*31mm
Weight: not more than 1.2kg (Except for LNGS.465213.270-95)
Contactor control module nominal output voltage: 220V
Contactor control module nominal output current: up to 1A
Out of service input type: potential
Out of service input nominal voltage: 24V
Input/output types, its specification and possible usage options are shown in Table 2.
Table 2
Input
Output
Name
Specification
Usage option
USER 1
USER 1
Input/Output
Input-dry contact;
Output-v5V,
max.current 170mA
User defined
USER 2
USER 2
Input/Output
Input-dry contact;
Output-v5V,
max.current 170mA
User defined
USER 3
USER 3
Input/Output
Input-dry contact;
Output-v5V,
max.current 500mA
User defined
USER 4
USER 4
Input/Output
Input-dry contact;
Output-v5V,
max.current 200mA
User defined, GOS
input
OUT 1
Output OUT1
Output-v5V,
max.current 1200mA
Dispatcher control,
voice alert control,
emergency light
control, GOS power
supply
LU’s input/output types and its possible wirings shown in Appendix C.
Changes to connecting for option LNGS.465213.270-10
For lifts without serial interface as well as for lifts having relay logic controller as additional adaptor (the Relay Station
Adapter) should be usrd
– LNGS.465213.161-01
Changes to connecting for option LNGS.465213.270-21
Connection to escalators with controller having no serial interface is performed via the RSA.
Changes to connecting for option LNGS.465213.270-53 and LNGS.465213.270-95
Connection to lifting platforms for disabled and handicapped passengers, with no serial interface available should be
performed with the use of dry contact inputs.
Changes to connecting for option LNGS.465213.270-11 and LNGS.465213.270-
14…LNGS.465213.270-20,
LNGS.465213.270-
22…LNGS.465213.270-94, LNGS.465213.270-96…LNGS.465213.270-119
Connection to microprocessor control boards via serial interface.
The operation time of the lift unit 7.2 and Intercom unit 7.2 powered from built in accumulator batteries is not less than
1 hour.
LIFT UNIT FUNCTIONS
As a part of LMDS, the LU performs monitoring of a lift operation and provides:
two-way voice communication between a dispatcher and a lift cabin, cabin roof, machine room, lift pit and
landing platform; it also provides audio signaling when calling dispatcher;
warning on landing door opening when a cabin is not at the leveling zone;
warning on the machine room door opening or control cabinet door opening (in case of machine room-less
lifts;