background image

7 (9)

• If the pressure sensor manages to find a 

leak 

, the STATUS LED starts flashing YEL-

LOW.  

If the pressure sensor does not find a leak,  

redo the steps with a slightly larger leak. 

3.  Close the tap and press the WATER ON/

OFF button to open the valve again. 

Leakage control with flow

1.  Open a tap with the valve in the open posi-

tion.

2.  Leave the valve at full flow on the tap for at 

least 40 minutes.

3.  Check that the unit emits an alarm after 30  

minutes and switches off the flow after 40 

minutes. 

4.  Then close the tap and reset the unit.

Alarm

Small leak 

• The unit will emit an alarm after micro-leak-

age for at least  

48 hours and shut off the water after 24 

hours. 

Medium-sized leak 

• The unit will emit an alarm and shut off the 

water after a leak with continuous flow for at 

least 45 minutes. 

Large leak 

• The unit will emit an alarm when the flow 

is continuous for at least 45 seconds and the 

flow is above 1500 l/h.

Acknowledge alarm

Press the WATER ON/OFF button once to ac-

knowledge the alarm. 

Factory reset of the unit

Firstly, insert a paper clip into the hole on the re-

set button while plugging in the power cable. 

CONNECT 

LED

Meaning

Dark/Off

Wi-Fi configured and con

-

nected.

WHITE 

Flashing

The unit is in hotspot mode 

for Wi-Fi configuration.  

RED 

Flashing

No Internet contact with the 

Wi-Fi network.

YELLOW 

Flashing

Ongoing pairing

establishment between two 

water safety system units, 

one for cold water and one for 

hot water. 

YELLOW/

BLUE  

Flashing

Pairing completed 

between the hot and cold 

water units. The connection 

is made from the cold water 

unit which flashes YELLOW/

BLUE. 

YELLOW/

RED 

Flashing

Pairing completed between 

the hot and cold water units. 

The connection is made from 

the hot 

 water unit which flashes 

YELLOW/RED.  

GREEN

Flashing

Pairing has been successful 

and is completed.

Start-up and function check

Check that the ball valve is working

1.  Press the WATER ON/OFF button.  

The LED starts flashing RED. The LED 

shines solid RED when the ball valve has 

completely shut off the water flow. 

2.  Open a tap. Check that  

no water comes out of the tap. 

3.  Press the WATER ON/OFF button.  

The LED goes off when the valve is fully 

open. Check that water is now coming out 

of the open tap.

Check that the pressure sensor is working

1.  Open a tap to simulate a very small leak. A 

dripping stream of water will suffice.

2.  Press the WATER ON/OFF button to close 

the valve. 

• When the valve is closed, the STATUS  

LED will flash GREEN while the pressure 

sensor scans for small leaks for about 45 

seconds.

EN.40.C.12.2021-12-06

Содержание CubicSecure

Страница 1: ...em description LK CubicSecure is a small unit that is easy to install in confined spaces The unit is easily in stalled on incoming water pipes for a house or apartment The water safety system is equipped with a switch for manual shut off in the event of power failure or emergency NOTE Two water safety systems can be paired in order to avoid scalding in apartments Pairing provides a synchronised au...

Страница 2: ...er safety system is equipped with a G20 EuroCone external thread which is to be installed with an LK PressPex press connection coupling or LK Pushfit AX connection coupling When using a flat gasket LK Plain Adapter is supplied RKS 187 06 78 with the product NOTE Safety systems such as residential sprinklers and emergency cooling of solid fuel boilers or similar must be connected before the water s...

Страница 3: ...K app 1 Download and install the LK app from the App Store or Google Play Store 2 Launch the LK app and log in The login page in the LK app Startup 1 Connect power to the unit using the micro USB power adapter included The water safety system connected to the power source 2 Check that the STATUS LED is WHITE White light indicates that the unit is work ing normally If no LEDs are lit check that the...

Страница 4: ...e_XXXX 8 Select the name of the wireless network and enter the password 9 Confirm your selection by pressing FLASH ES WHITE Selecting a wireless network 3 Check that the STATUS LED is WHITE 4 Confirm by pressing GLOWS WHITE White light the unit is working normally 5 Press the CONNECT button and check that it starts flashing WHITE 6 Confirm by pressing FLASHES WHITE White flashing light CONNECT EN ...

Страница 5: ...ter pipes to protect against any leakage and avoid possible scalding Manual pairing 1 Install and start the units One for hot water and one for cold water 2 Hold down the CONNECT button for five seconds on the unit installed for cold water The CONNECT LED starts flashing YEL LOW and BLUE 3 Hold down the CONNECT button for five seconds on the unit installed for hot water The CONNECT LED starts flas...

Страница 6: ... valve is open The water supply flow is on Dark Off The valve is open The water supply flow is off WHITE Flashing Indicates that there is an ongoing water flow YELLOW The position of the valve has been changed using the man ual switch Press the WATER ON OFF button to turn off the warning alarm function RED The water pressure is very low or there is no water in the pipe Check that the water system ...

Страница 7: ...nfigured and con nected WHITE Flashing The unit is in hotspot mode for Wi Fi configuration RED Flashing No Internet contact with the Wi Fi network YELLOW Flashing Ongoing pairing establishment between two water safety system units one for cold water and one for hot water YELLOW BLUE Flashing Pairing completed between the hot and cold water units The connection is made from the cold water unit whic...

Страница 8: ...urements via the LK app Various data such as temperature volume water pressure valve position and no leakage detected are displayed for each unit When LK CubicSe cure is in operation it performs automatic leak age tests If a fault occurs during operation the water safety system will emit an alarm and close the valve Measured values from the water safety system are shown in the LK app Use of large ...

Страница 9: ...nt LK Systems is affiliated with El Kretsen for col lecting and recycling electronics and batteries Used batteries should be sorted as batteries or small batteries and deposited for battery recy cling When the system has reached the end of its life it should be sorted as electronics or other electronics and deposited with a recycling centre Guarantee LK Systems AB is responsible for faults in prod...

Отзывы: