background image

6 (9)

Summary of LEDs

STATUS LED

Meaning

WHITE

The unit is switched on and 

active, and no errors or 

alarms are indicated. 

Dark/Off

The unit is not powered. 

Make sure the unit is con-

nected to a power source. 

Check that the power source 

is working properly. 

YELLOW

Leak detection is deactivated. 

Press the WATER ON/OFF 

button to activate the func-

tion. 

YELLOW  

Flashing

Detected leakage. 

WHITE  

Flashing

The unit is being updated and 

other functions are temporar-

ily disabled. Do not discon-

nect the power source. 

GREEN  

Flashing

The unit is collecting data on 

the water pressure and has 

closed the valve in the mean-

time. Data collection con-

tinues for up to one minute, 

after which the unit opens the 

valve again. 

RED

The unit is not working/is not 

working properly. Contact 

technical support. 

WATER ON/

OFF LED

Meaning

WHITE

The valve is open. The water 

supply/flow is on. 

Dark/Off

The valve is open. The water 

supply/flow is off.

WHITE 

Flashing

Indicates that there is an 

ongoing water flow. 

YELLOW

The position of the valve has 

been changed using the man-

ual switch. Press the WATER 

ON/OFF button to turn off the 

warning/alarm function. 

RED

The water pressure is very 

low or there is no water in the 

pipe. Check that the water 

system is working properly. 

CONNECT 

LED

Meaning

WHITE

Wi-Fi configured and con

-

nected.

4.  Make sure that the CONNECT LEDs on 

both units flash GREEN rapidly for about a 

second.

5.  If pairing was not completed,  

redo process steps 2 to 4. 

Pairing via the LK app

Pairing can also be done via the LK app if the 

units are connected to Wi-Fi and added to the 

same account. Follow the instructions in the LK 

app. 

functions

1.  Valve switch.
2.  Reset button (factory setting)
3.  CONNECT LED for pairing.
4.  CONNECT button for pairing. 
5.  STATUS LED (red, green, white and yel-

low).

6.  ON/OFF button for water.
7.  ON/OFF LED for water.

EN.40.C.12.2021-12-06

Содержание CubicSecure

Страница 1: ...em description LK CubicSecure is a small unit that is easy to install in confined spaces The unit is easily in stalled on incoming water pipes for a house or apartment The water safety system is equipped with a switch for manual shut off in the event of power failure or emergency NOTE Two water safety systems can be paired in order to avoid scalding in apartments Pairing provides a synchronised au...

Страница 2: ...er safety system is equipped with a G20 EuroCone external thread which is to be installed with an LK PressPex press connection coupling or LK Pushfit AX connection coupling When using a flat gasket LK Plain Adapter is supplied RKS 187 06 78 with the product NOTE Safety systems such as residential sprinklers and emergency cooling of solid fuel boilers or similar must be connected before the water s...

Страница 3: ...K app 1 Download and install the LK app from the App Store or Google Play Store 2 Launch the LK app and log in The login page in the LK app Startup 1 Connect power to the unit using the micro USB power adapter included The water safety system connected to the power source 2 Check that the STATUS LED is WHITE White light indicates that the unit is work ing normally If no LEDs are lit check that the...

Страница 4: ...e_XXXX 8 Select the name of the wireless network and enter the password 9 Confirm your selection by pressing FLASH ES WHITE Selecting a wireless network 3 Check that the STATUS LED is WHITE 4 Confirm by pressing GLOWS WHITE White light the unit is working normally 5 Press the CONNECT button and check that it starts flashing WHITE 6 Confirm by pressing FLASHES WHITE White flashing light CONNECT EN ...

Страница 5: ...ter pipes to protect against any leakage and avoid possible scalding Manual pairing 1 Install and start the units One for hot water and one for cold water 2 Hold down the CONNECT button for five seconds on the unit installed for cold water The CONNECT LED starts flashing YEL LOW and BLUE 3 Hold down the CONNECT button for five seconds on the unit installed for hot water The CONNECT LED starts flas...

Страница 6: ... valve is open The water supply flow is on Dark Off The valve is open The water supply flow is off WHITE Flashing Indicates that there is an ongoing water flow YELLOW The position of the valve has been changed using the man ual switch Press the WATER ON OFF button to turn off the warning alarm function RED The water pressure is very low or there is no water in the pipe Check that the water system ...

Страница 7: ...nfigured and con nected WHITE Flashing The unit is in hotspot mode for Wi Fi configuration RED Flashing No Internet contact with the Wi Fi network YELLOW Flashing Ongoing pairing establishment between two water safety system units one for cold water and one for hot water YELLOW BLUE Flashing Pairing completed between the hot and cold water units The connection is made from the cold water unit whic...

Страница 8: ...urements via the LK app Various data such as temperature volume water pressure valve position and no leakage detected are displayed for each unit When LK CubicSe cure is in operation it performs automatic leak age tests If a fault occurs during operation the water safety system will emit an alarm and close the valve Measured values from the water safety system are shown in the LK app Use of large ...

Страница 9: ...nt LK Systems is affiliated with El Kretsen for col lecting and recycling electronics and batteries Used batteries should be sorted as batteries or small batteries and deposited for battery recy cling When the system has reached the end of its life it should be sorted as electronics or other electronics and deposited with a recycling centre Guarantee LK Systems AB is responsible for faults in prod...

Отзывы: