EN.33.C.104.1012
Mounting in the manifold cabinet
At delivery, the receiver unit is fitted with a short antenna cable for internal mounting of the radio link. If the
receiver unit is installed in a sheet metal manifold cabinet, it is recommended that the radio link should be fixed
outside the cabinet. Use accessory LK Antenna Cable ICS for simplicity.
Description of inputs/outputs/features
Description of the program keys (illus. 1 - 4)
Remove the receiver unit cover; the following keys are displayed:
U-key, used if the unit's software needs updating; separate instructions accompany any software update. (1)
A-key, used in combination with other keys to get alternate functions. (2)