background image

9 (9)

EN.33.C.111.1804

Assembly instructions | LK Electric Boiler - 4,5

Technical data

Article no.

623 12 25

Height

700 mm

Width

420 mm

Depth

200 mm

Weight

17 kg

Output

4,5 kW

Voltage

400V AC 3N~, 50 Hz

Current

6,5 A

Protection Class

IP 21

Power circulation pump

2-34 W

Volume

5,5 litres

Volume expansion vessel

2 litres

Calculation pressure

2,5 bar

Test pressure

3,6 bar

Safety valve

2,5 bar

Calculation temperature

80 °C

Control temperature

10-60°C

Manufactured in accor-

dance with:

AFS 1999:4§8 97/23 EG 

article 3

Fuse

3 x 10A

Condensing boiler

no

Low-temperature

no

B1 boiler

no

Cogeneration space heater no
Combination heater

no

Rated heat output

P

rated

5

kW

Useful heat output at rated 

heat output

P

4

4,5

kW

Energy class

D

Seasonal space heating 

energy efficiency

boiler 

boiler 

with 

UTK

η

η

s

36 

38

%

Useful efficiency

η

4

39,7

%

Auxiliary electricity 

consumption

in stand-

by mode

P

SB

0,019 kW

Standby heat loss

P

stby

0,037 kW

Material recycling

After dismantling the boiler must be recycled. 

The insulation is removed and recycled as insula-

tion. Boiler Body recycled as scrap steel. Electrical 

and electronic components are sorted as electro-

nic waste. Boiler casing recycled as plastic.

Dimensional drawings

150

189

224

515

173

392

171

50

50

640

Without cover

200

700

420

With cover

LK Systems AB, Box 66, 161 26 Bromma, Sweden | www.lksystems.se

Содержание Electric Boiler-4.5

Страница 1: ...wall mounted elec tric boiler intended primarily for low temperature heating systems e g under floor heating LK Electric Boiler 4 5 kW is delivered as a complete unit The boiler is ready for use once the water and electricity are connected The boiler includes Thermostat Overheating maximum safe temperature protection Indication power on and triggered overhea ting maximum safe temperature protectio...

Страница 2: ...stment valve should be open by at least half a revolution 1 2 1 Isolation valve supply and return 2 By pass valve accessible after the protective plug has been unscrewed Installation system outline Below is a system outline Units should always be installed according to regulations and standards 4 1 2 3 1 LK Electric Boiler 4 5 2 Filling valve Drain valve 3 Manifolds under floor heating 4 Under flo...

Страница 3: ...de any one of 10 curves can be selected by turning the button When the button has been released for 10 sec the pump returns to operat ing mode the LEDs stop flashing and the selected curve becomes active A lit red LED indicates an alarm or warning Indication Fault Status Measure Red fourth yellow Motor blocked Pump tries to restart at 1 5 sec intervals Release motor impeller or wait Red third yel ...

Страница 4: ...ied out under the supervision of an authorized installer Electric installation Electric installation should be carried out in accor dance with the applicable regulations under the supervision of an authorized electrician The boiler must not be connected to the electrical supply before it is filled with water The boiler should be preceded by all pole circuit switches The ambient temperature must no...

Страница 5: ...capacitor 5 Circulation pump 6 Overheating maximum safe temperature protection 7 Thermostat 8 Electric cartridge 9 Control switches 10 Alarm indication overheating maximum safe temperature protection triggered 11 On off indicating light goes on when vol tage is supplied to the boiler 12 Contacts External switching room thermostat The boiler can be blocked by external equipment e g room thermostat ...

Страница 6: ...perature protection triggered Inspect together with installer after the instal lation that the unit is in a satisfactory condition Have the installer demonstrate how the unit works and should be handled The boiler and the heating system must be filled with water before the circuit switch is set to on The boiler cover should be assembled during ope ration Note Monitor the amount of water in the ves...

Страница 7: ...ox 35 40 C and for wooden joists approx 40 45 C The desired temperature varies according to the time of year Safety valve The safety valve should be exercised regularly to maintain the safety function Overheating maximum safe temperature protection The overheating maximum safe temperature pro tection on the boiler is triggered when the boiler temperature exceeds 80 The protection is restored on th...

Страница 8: ... the boiler temperature falls below 65 C push the button hard for reset No or insufficient heat Thermostatic valves on the heating system or boiler thermostat set at too low temperature Inspect and adjust Faulty adjustment of bypass valve Inspect and adjust Group fuses for boiler are triggered The electric cartridge is broken Inspect the electric cartridge by testing it in isolation Measure betwee...

Страница 9: ...iler no Cogeneration space heater no Combination heater no Rated heat output Prated 5 kW Useful heat output at rated heat output P4 4 5 kW Energy class D Seasonal space heating energy efficiency boiler boiler with UTK ηs ηs 36 38 Useful efficiency η4 39 7 Auxiliary electricity consumption in stand by mode PSB 0 019 kW Standby heat loss Pstby 0 037 kW Material recycling After dismantling the boiler...

Отзывы: