background image

   

Table of Contents

1.00 Warranty

 .....................................................................................................................2

 

1.10   Exceptions

 

1.20   Provisions

2.00 Introduction

 ................................................................................................................2

 

2.10   Important Note on Application

 

2.20   General Operating Conditions

3.00 Mechanical Installation

 .............................................................................................2

 

3.10  Sight Glass Types and Sizes Suitable for Mounting

 

3.20   Mechanical Installation – USL13

 

 

3.21  Mounting using Hinged Bracket

 

 

3.22  Mounting using Flange Adapter

 

3.30  Mechanical Installation – USL33

 

 

3.31  Assembly to Sight Glass

4.00   Electrical Installation

 .............................................................................................2

 

4.10   Supply Requirements

 

 

4.11  Notes

 

4.20   Electrical Connection

 

 

4.21  M12 Connector – for Remote Push-Button Operation

 

 

4.22  Standard Electrical Connection

5.00 Operation

 ....................................................................................................................2

 

5.10  Continuous Mode – for Indicator-Equipped Luminaire

 

5.20  Button Operation – for Button-Equipped Luminaire 

6.00 Safety

 ...........................................................................................................................2

7.00 Maintenance

 ...............................................................................................................2

Manual:  02-0158 - IOM 

1

 05/22

Содержание LumiStar 1000

Страница 1: ...Sight Glass Installation Operation Maintenance Manual P O Box 1116 Twinsburg OH 44087 Phone 330 405 3040 Fax 330 405 3070 E mail view ljstar com Web Site www ljstar com LumiStar 1000TM LED 12 24V Installation and Operating Instructions ...

Страница 2: ...ing using Hinged Bracket 3 22 Mounting using Flange Adapter 3 30 Mechanical Installation USL33 3 31 Assembly to Sight Glass 4 00 Electrical Installation 2 4 10 Supply Requirements 4 11 Notes 4 20 Electrical Connection 4 21 M12 Connector for Remote Push Button Operation 4 22 Standard Electrical Connection 5 00 Operation 2 5 10 Continuous Mode for Indicator Equipped Luminaire 5 20 Button Operation f...

Страница 3: ... indirectly related to the installation or use of its products or from any other cause or for consequential damages It is expressly understood that L J Star is not responsible for damage or injury caused to other products building property or persons by reason of the installation or use of its products This warranty is in lieu of any other warranty expressed or implied by any party other than L J ...

Страница 4: ...s using supplied M6 screw 3 22 Mounting using Flange Adapter Flange adapter mounting is required for DIN 11851 units in sizes DN50 and DN65 Adapter fits under the slotted cover nut of DIN 11851 unit Place gasket between adapter and glass Tighten slotted cover nut Place LumiStar1000 into adapter sleeve Tighten set screws to secure 3 30 Mechanical Installation USL33 The LumiStar1000 LED USL33 lumina...

Страница 5: ...E WITH NO POWER SUPPLIED TO LIGHT FAILURE TO DO SO COULD RESULT IN PERSONAL INJURY AND OR PROPERTY DAMAGE 5 pin A type M12 connector cable 3 meter length is supplied with Luminaire Connect cable to light Connect free wires per chart below Unit is internally wired ready for operation Brown Blue Gray Black White Vin Vin GND Ext Switch Ext Switch 4 22 Standard Electrical Connection WARNING ELECTRICAL...

Страница 6: ... LED on the switch will blink twice while the processor initializes The LED will then periodically flash to indicate power is applied One Button Press 2 minute on time Light shuts off after 2 minutes Second press turns off light Two Rapid Presses 30 minute on time Light shuts off after 30 minutes Additional press turns off light Three Rapid Presses Light becomes dimmable The light will dim 10 for ...

Страница 7: ...d free of dust Inspect luminaire for damage to glass Inspect luminaire for inadequate sealing shown by moisture buildup on the interior of the lens Do not open the luminaire to perform service In the event of a malfunction please contact L J Star to coordinate service ...

Страница 8: ......

Отзывы: