23
6.7
Smart Meter Connection
Procedure:
STEP 1:
•
Normally the smart meter should be placed in or near the grid
distribution box right after the billing meter.
STEP 2:
•
Please use the smart meter cable in the
accessory box for communication.
Insert the RJ45 connector with water-
proof cap into the port marked
“MULTI” on inverter and fasten the
cap.
STEP 3:
•
The wires on the other end should be stripped and connected to
the smart meter accordingly. If the cable length is not enough,
please use the RJ45 extender in accessary box to extend the
cable.
3 different terminal resistors (240Ohm, 510Ohm, 1kOhm) are
provided with the smart meter. If you are using the cable supplied with
the inverter, and not extending or replacing it, you should not require
these. If you are extending the supplied cable or using your own
communication cabling, it is recommended to install the 1kOhm
resistor across the communication terminals (7 + 8) of the smart
meter.
“MULTI” Connector Pin Definition
1.
METER_485B
2.
METER_485A
3.
GND
4.
Reserved
5.
Reserved
6.
GND
7.
Reserved
8.
Reserved
1
2
3
4
5
6
7
8