20
•
Earth connection essential before connecting supply.
6.5
EPS Connection
If you want to use the energy storage system to power the house (as a standalone
system or during Grid failure), the EPS connector should be used and the EPS
function should be enabled during setup. Otherwise you could leave the EPS
port disconnected. Where possible, please install an external switch to bypass
the inverter to power backup loads in the event of inverter failure.
Before connecting, please check the following:
•
The grid voltage and frequency must be in the permissible range.
•
External AC switches must be used on EPS connection to cut off the inverter
from EPS load when necessary.
Procedure:
STEP 1:
•
Assemble the EPS connector.
•
Make sure Live/Neutral/PE wires are
correct; please follow the markings on
the connector
STEP 2:
•
Connect the EPS plug to the inverter. A
“click” sound will
indicate firm connection.