Automatic Electrode Cleaning, continued
• The LCD display will indicate when the automatic electrodes cleaning begins. The word “clean” will display inside the
fan symbol after approximately 40~50 liters of ionized water is produced.
• Once cleaning is performed, the LCD screen will change back to Blue.
• Every 2850 Liters, use the citric acid cleaning cartridge to clean the system.
NOTE:
Cleaning cycle occurs every 40 Liters of total water usage. Total water usage includes both alkaline and acidic water produced.
Testing the pH
CAUTION:
- Keep the testing kit away from fire.
- Testing kit and/or water with testing solution should not be ingested or dropped in eyes.
- Keep the testing kit out of children’s reach.
- If accidentally ingested, drink a lot of alkaline water and go to the hospital immediately.
- If solution comes in contact with eyes, flush the eyes with water and go to the hospital immediately.
1.
Add 2 drops of the pH/chlorine testing solution to 1.0~1.5 oz sample water.
2.
Compare the resulting hue to the pH color chart. The corresponding hue is the pH level.
3.
The chlorine test result should be yellow from your tap water, and colorless from the ionized water.
NOTE:
Both the pH and chlorine test is an approximation. Digital meters are required for exact measurement.
NOTE:
pH levels are dependent upon the TDS levels of the incoming water source. If adjustments are necessary to achieve optimal
water production, contact your dealer for instructions.
13
12
FILTER REPL ACEMENT
1.
Replace the filter when the Filter Replacement Indicator glows red. The LCD screen will flash red as well.
The light on the indicator will glow once approximately 10,000L of water has passed through the ionizer. Citric acid
cleaning cartridge is needed for proper cleaning every 2850 Liters.
!
WARNING:
Replace the filter immediately If the following events occur.
- Water has a very bad smell.
- Unit has been unused for over one year.
- Water pressure is severely low.
NOTE:
The filter life is reduced by low water pressure, turbid water, and high TDS.
1.
To replace the filter, turn off the water, and unplug the unit. Next, remove the unit from the wall.
2.
Press the filter access door cover and take the cover off.
3.
Hold the old filter at the top and rotate counter clockwise.
4.
Put the new filter in place and rotate clockwise until completely tight.
If there are no problems replacing the filter, then put the cover back and attach unit to the wall. In case of a leak, repeat
procedure again from the start. If problem persists, contact the supplier.
NOTE:
Please note that after changing the filter, you should let the water run for 3-5 minutes on the “Filtered Water” setting to clean
out any loose carbon particles from the filter. The water may appear a darker color at first, but this will disappear as the water runs.
1.
2.
3.
5.
After changing the filter, press and hold the “set” button for 8-10 seconds.
6.
LCD will display 4 selections. Press the Decrease button (-) and select the 2nd option on the display.
7.
Press the "Set" button once.
8.
Press the Filter Reset button once to reset filter life.
9.
Filter life will indicate 10,000L. Press the "Set" button again.
10.
To return to normal operation mode, press any of the pH buttons.