Automatic Electrode Cleaning, continued

• The LCD display will indicate when the automatic electrodes cleaning begins. The word “clean” will display inside the

fan symbol after approximately 40~50 liters of ionized water is produced.

• Once cleaning is performed, the LCD screen will change back to Blue.

• Every 2850 Liters, use the citric acid cleaning cartridge to clean the system.

NOTE:

Cleaning cycle occurs every 40 Liters of total water usage. Total water usage includes both alkaline and acidic water produced.

Testing the pH

CAUTION:

- Keep the testing kit away from fire.

- Testing kit and/or water with testing solution should not be ingested or dropped in eyes.

- Keep the testing kit out of children’s reach.

- If accidentally ingested, drink a lot of alkaline water and go to the hospital immediately.

- If solution comes in contact with eyes, flush the eyes with water and go to the hospital immediately.

1.

Add 2 drops of the pH/chlorine testing solution to 1.0~1.5 oz sample water.

2.

Compare the resulting hue to the pH color chart. The corresponding hue is the pH level.

3.

The chlorine test result should be yellow from your tap water, and colorless from the ionized water.

NOTE:

Both the pH and chlorine test is an approximation. Digital meters are required for exact measurement.

NOTE:

pH levels are dependent upon the TDS levels of the incoming water source. If adjustments are necessary to achieve optimal

water production, contact your dealer for instructions.

13

12

FILTER REPL ACEMENT

1.

Replace the filter when the Filter Replacement Indicator glows red. The LCD screen will flash red as well.

The light on the indicator will glow once approximately 10,000L of water has passed through the ionizer. Citric acid

cleaning cartridge is needed for proper cleaning every 2850 Liters.

!

WARNING:

Replace the filter immediately If the following events occur.

- Water has a very bad smell.

- Unit has been unused for over one year.

- Water pressure is severely low.

NOTE:

The filter life is reduced by low water pressure, turbid water, and high TDS.

1.

To replace the filter, turn off the water, and unplug the unit. Next, remove the unit from the wall.

2.

Press the filter access door cover and take the cover off.

3.

Hold the old filter at the top and rotate counter clockwise.

4.

Put the new filter in place and rotate clockwise until completely tight.

If there are no problems replacing the filter, then put the cover back and attach unit to the wall. In case of a leak, repeat

procedure again from the start. If problem persists, contact the supplier.

NOTE:

Please note that after changing the filter, you should let the water run for 3-5 minutes on the “Filtered Water” setting to clean

out any loose carbon particles from the filter. The water may appear a darker color at first, but this will disappear as the water runs.

1.

2.

3.

5.

After changing the filter, press and hold the “set” button for 8-10 seconds.

6.

LCD will display 4 selections. Press the Decrease button (-) and select the 2nd option on the display.

7.

Press the "Set" button once.

8.

Press the Filter Reset button once to reset filter life.

9.

Filter life will indicate 10,000L. Press the "Set" button again.

10.

To return to normal operation mode, press any of the pH buttons.

Содержание ESSENTIAL C7

Страница 1: ...tments LLC 300 East Valley Drive Bristol VA 24201 800 989 2299 OWNER S MANUAL C7 MODEL WATER IONIZER CAUTION Read manual carefully for proper procedures and operation EA 03207 2009 DBG Group Investments LLC All rights reserved ...

Страница 2: ...ng codes can result in leaks and or water damage and will void your warranty We expressly disclaim any liability for damage caused by leaks and or other water damage Chlorine and pH Test Reagents Do not expose the pH or chlorine test reagents to extreme heat or flames They are combustible Store in a cool dry location Keep the reagents tightly sealed and store out of the reach of children Do not dr...

Страница 3: ...daches rashes diarrhea and or nausea You may notice differences in bowel habits during the first days at each pH level Urine frequency may increase and color may darken as more water is consumed and your body detoxifies Eventually the color decreases as your body adjusts to the cleansing If detoxification symptoms become uncomfortable it is suggested that you decrease to a lower level alkaline wat...

Страница 4: ...electrician if you are not sure whether the electrical outlet you intend to use is properly installed Do not modify the electrical power cord or plug provided with the water ionizer and do not use a three prong to two prong adapter Improper grounding can result in risk of electric shock as well as damage to the water ionizer Do not plug the water ionizer into an electrical outlet that will result ...

Страница 5: ...he quick connect connectors will swivel to accommodate exit from either side Place the water ionizer in an upright position Faucet Diverter Installation Remove the aerator from the faucet head Put this in a location where you can find it if you ever need to reinstall it onto the faucet at a later date This is usually done without tools by rotating counter clockwise 1 Slip on the rubber sealing rin...

Страница 6: ...he use of the Super Charger Filter optional High alkaline water is excellent for cleaning NOTE Please note that after you turn off the water the LCD display will automatically turn off the light one minute later The pH selection button light will remain on PH ORP LIFE 8 5 160 mv 12000L FLOW DRINKING 3 4 L m FLOW DRINKING 3 4 L m PH ORP LIFE 8 5 160 mv 12000L Electrode clean 3 4 L m FLOW Electrode ...

Страница 7: ...he filter when the Filter Replacement Indicator glows red The LCD screen will flash red as well The light on the indicator will glow once approximately 10 000L of water has passed through the ionizer Citric acid cleaning cartridge is needed for proper cleaning every 2850 Liters WARNING Replace the filter immediately If the following events occur Water has a very bad smell Unit has been unused for ...

Страница 8: ...sically hold the lever on the faucet diverter valve in the out position as there may not be enough water pressure to automatically keep the lever in the on position NOTE Hold a glass or cup under the spout to catch the water coming out of the hose Instructions for Cleaning the Electrode Plates continued Adjust the water flow until there is a rapid sequence of drops coming out of the ionized water ...

Страница 9: ...ked or bent restrictions Replace with new filter pg 13 Straighten hose Open inlet valve completely Replace with new filter pg 13 or use a sulphur pre filter Use a citric acid cleaning cartridge Filter needs replacing or water is too strong Drink on lower setting Contact your Dealer Reset filter life see pg 13 Plug unit into power source Test electrical outlet or call your electrician Turn on the f...

Страница 10: ...sotherthanthose providedbyourauthorizedServiceCenter Thiswarrantydoesnotcoveranywaterdamage EXCLUSION OF OTHER WARRANTIES AND CONDITIONS EXCEPT AS PROVIDED HEREIN WE MAKE NO REPRESENTATION OR WARRANTY OF ANY KIND ALL OTHER WARRANTIES OF ANY KIND EXPRESS OR IMPLIED ARE HEREBY EXPRESSLY DISCLAIMED INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE LIMITATION OF LIA...

Отзывы: