PLEASE READ THIS MANUAL PRIOR TO INSTALLATION AND OPERATION

Important Safety Information

To reduce the risk of fire, electrical shock, or injury:

• Use only as described in this manual. Use only manufacturer’s recommended attachments.

• Do not handle plug or appliance with wet hands.

• Unplug cord from outlet before servicing or replacing filters.

• Do not use with damaged cord or plug.

• Do not unplug by pulling on cord. To unplug, grasp the plug, not the cord.

• Do not operate if connections leak or leakage appears when water source is turned on.

• Do not attempt to remove the back cover or attempt to access the inner workings of the ionizer. There are no self-

serviceable components, aside from filter replacement or use of the cleaning cartridge, which is accessed by a

removable cover panel.

• Keep unit away from extreme environmental conditions.

• Maintain a clean and dry area around the ionizer. Never allow the unit to sit in standing water.

• Your new water ionizer is intended as a point-of-use appliance only. Serious damage may result from misuse of your

unit.

• Do not use with micro-biologically unsafe water.

• This unit may be used in conjunction with pre-filters on your tap water. It is not intended for use with reverse osmosis

systems and/or water softening systems.

• DO NOT DRINK THE WATER DURING THE AUTOMATIC CLEANING CYCLE. The cleaning cycle will occur after every

40 liters of water flow. This feature helps keep minerals from building up on the electrode. The citric acid cleaning

cartridge is used every 2850 Liters to clean the system.

• No medical claims have been made by the manufacturer or distributor. Always see your physician at the first signs of

illness. The manufacturer or distributor is not responsible for adverse effects that may result from the use or misuse

of ionized water.

CAUTION:

Damage will occur if unit is exposed to hot water. Be certain that only cold or room temperature water enters the water

ionizer. A temperature sensor will protect the unit temporarily, but continued use of hot water will damage the ionizer.

2

PLEASE READ THIS MANUAL PRIOR TO INSTALLATION AND OPERATION

IMPORTANT NOTICE:

Failure to install according to the Installation Guide and in accordance with applicable city, state and local

plumbing codes can result in leaks and/or water damage and will void your warranty. We expressly disclaim any liability for damage

caused by leaks and/or other water damage.

Chlorine and pH Test Reagents

• Do not expose the pH or chlorine test reagents to extreme heat or flames. They are combustible. Store in a cool/dry

location. Keep the reagents tightly sealed and store out of the reach of children.

• Do not drink the pH or chlorine test reagents or allow them to get into your eyes. Do not apply to the body.

o If either is ingested, do not induce vomiting and call a physician or poison control immediately.

o If either gets into your eyes, flush immediately with cool water. Call a physician.

o If either gets on your body, wash off immediately with cool water. Call a physician.

Disclosures:

• No medical claims are made by the manufacturer or distributor or are they responsible for any adverse effects that

may result from the use, or misuse of ionized water.

• Verify with your physician that prescribed medications or existing conditions will not be affected by drinking alkaline

water.

• Do not take medications with Alkaline water as alkaline ionized water may increase the effectiveness of the

medication.

• Do not drink alkaline water if you have achlorhydia.

• Consult your physician before drinking alkaline water if you have:

o A chronic disease

o A dysfunctional liver or intestines

o Are currently under medical treatment

• Consult your physician if you have sensitive skin or allergies before using acidic water on your skin or hair.

• Consumption of alkaline water that is too high (greater than pH 9.5) may cause diarrhea or other symptoms.

• The unit is NOT INTENDED for use on microbiologically unsafe water. If you are unsure of the safety of your water

source, have your water tested by a qualified water testing laboratory.

• Failure to comply with installation and operation instructions provided in this user’s manual or modification of any

part of the system may invalidate the warranty. We are not liable for damage to the unit or personal injury as a result

of improper installation or operation of the system.

IMPORTANT:

DO NOT drink any of the following water types:

ANY acidic water

High pH alkaline water (above 9.5 pH)

Water produced during the auto flush (electrode cleaning) process.

When no pH value is displayed on the LED display.

When the C7 unit has not been used for more than two days, let water run for 30 seconds before consuming.

3

Содержание ESSENTIAL C7

Страница 1: ...tments LLC 300 East Valley Drive Bristol VA 24201 800 989 2299 OWNER S MANUAL C7 MODEL WATER IONIZER CAUTION Read manual carefully for proper procedures and operation EA 03207 2009 DBG Group Investments LLC All rights reserved ...

Страница 2: ...ng codes can result in leaks and or water damage and will void your warranty We expressly disclaim any liability for damage caused by leaks and or other water damage Chlorine and pH Test Reagents Do not expose the pH or chlorine test reagents to extreme heat or flames They are combustible Store in a cool dry location Keep the reagents tightly sealed and store out of the reach of children Do not dr...

Страница 3: ...daches rashes diarrhea and or nausea You may notice differences in bowel habits during the first days at each pH level Urine frequency may increase and color may darken as more water is consumed and your body detoxifies Eventually the color decreases as your body adjusts to the cleansing If detoxification symptoms become uncomfortable it is suggested that you decrease to a lower level alkaline wat...

Страница 4: ...electrician if you are not sure whether the electrical outlet you intend to use is properly installed Do not modify the electrical power cord or plug provided with the water ionizer and do not use a three prong to two prong adapter Improper grounding can result in risk of electric shock as well as damage to the water ionizer Do not plug the water ionizer into an electrical outlet that will result ...

Страница 5: ...he quick connect connectors will swivel to accommodate exit from either side Place the water ionizer in an upright position Faucet Diverter Installation Remove the aerator from the faucet head Put this in a location where you can find it if you ever need to reinstall it onto the faucet at a later date This is usually done without tools by rotating counter clockwise 1 Slip on the rubber sealing rin...

Страница 6: ...he use of the Super Charger Filter optional High alkaline water is excellent for cleaning NOTE Please note that after you turn off the water the LCD display will automatically turn off the light one minute later The pH selection button light will remain on PH ORP LIFE 8 5 160 mv 12000L FLOW DRINKING 3 4 L m FLOW DRINKING 3 4 L m PH ORP LIFE 8 5 160 mv 12000L Electrode clean 3 4 L m FLOW Electrode ...

Страница 7: ...he filter when the Filter Replacement Indicator glows red The LCD screen will flash red as well The light on the indicator will glow once approximately 10 000L of water has passed through the ionizer Citric acid cleaning cartridge is needed for proper cleaning every 2850 Liters WARNING Replace the filter immediately If the following events occur Water has a very bad smell Unit has been unused for ...

Страница 8: ...sically hold the lever on the faucet diverter valve in the out position as there may not be enough water pressure to automatically keep the lever in the on position NOTE Hold a glass or cup under the spout to catch the water coming out of the hose Instructions for Cleaning the Electrode Plates continued Adjust the water flow until there is a rapid sequence of drops coming out of the ionized water ...

Страница 9: ...ked or bent restrictions Replace with new filter pg 13 Straighten hose Open inlet valve completely Replace with new filter pg 13 or use a sulphur pre filter Use a citric acid cleaning cartridge Filter needs replacing or water is too strong Drink on lower setting Contact your Dealer Reset filter life see pg 13 Plug unit into power source Test electrical outlet or call your electrician Turn on the f...

Страница 10: ...sotherthanthose providedbyourauthorizedServiceCenter Thiswarrantydoesnotcoveranywaterdamage EXCLUSION OF OTHER WARRANTIES AND CONDITIONS EXCEPT AS PROVIDED HEREIN WE MAKE NO REPRESENTATION OR WARRANTY OF ANY KIND ALL OTHER WARRANTIES OF ANY KIND EXPRESS OR IMPLIED ARE HEREBY EXPRESSLY DISCLAIMED INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE LIMITATION OF LIA...