Mounting the solar cell
Make sure you will not be drilling into electrical,
gas or water lines inside the wall. Use a power
drill to drill the holes into the brick wall. Always
observe all safety instructions for the power drill
in the manual for the power drill. Death or injury
due to electric shock may otherwise result.
When selecting the mounting location for the
solar cell
12
, pay attention to the following:
The solar cell
12
needs to be as directly
exposed to sunlight as possible. Even partial
shading of the solar cell
12
during the day
can have a significant influence on charging.
Cardinal direction:
Orientation towards the south is optimum. Ori-
entations with slight deviations towards the west
are preferable to those with slight deviations
towards the east.
Horizontal orientation:
The horizontal orientation of the solar cell
12
depends on the geographic latitude of the
mounting location. In central Europe, and angle
of 30°–40° is ideal.
A mounting plate with 6 drill holes for screws is
located at the back of solar cell
12
.
Mount the solar cell
12
at the designated
location using the 4 small screws
13
and
dowels
15
. Depending on the topography
of the mounting location, you can freely
choose 4 of the drill holes in the mounting
plate; however, you should ideally select
2 drill holes on the right and left each (see
fig. B).
Then lay the solar cable plug
14
and con-
nect the plug to the solar electricity socket
8
of the spotlight
10
.
The solar cell
12
is originally connected to
the mounting plate via a swivel joint. Orient
the solar cell
12
in a manner that ensures
maximum exposure to sunlight.
Preparing the product
for use
Switching the motion
detector on and off
Press the ON / OFF switch
11
into the ON
position to switch on the motion detector
9
;
the red LED indicator of ON / OFF switch
11
lights on at the same time.
Press the ON / OFF switch
11
into the OFF
position to switch off the motion detector
9
;
the red LED indicator of ON / OFF switch
11
extinguish at the same time.
Setting the lighting duration
Turn the rotary control TIME
19
on the
bottom of the motion detector
9
clockwise
to increase the duration of the illumination
(see Fig. C). The lighting duration can be
adjusted within a time window of approx.
5s +/-2s to 5 min +/-1min.
Adjusting the sensitivity of
the sensor
Turn the rotary control SENS
18
on the
bottom of the motion detector
9
clockwise