9
GB/IE/NI
Before installation ensure that
the circuit, to which the light will
be connected, is not energised.
To do so, remove the fuse or
switch off the circuit breaker in
the fuse box (0 position).
Use the voltage tester to verify
the de-energised status.
The included mounting material
is suitable for ordinary solid
concrete or masonry construc-
tion. Check which mounting
material is suitable for your
chosen mounting surface. If
necessary, seek expert advice.
Installation
When selecting the mounting loca-
tion, pay attention to the following:
Make sure that the spot
1
illuminates the desired area. You
can move the spot vertically.
Make sure the motion detector
7
covers the desired area. The
motion detector has a maximum
coverage range of 12 m, with a
coverage angle of about 180°
(depending on the mounting
height – a height of 2.50 m is
ideal) (Fig. D).
Make sure the motion detector
is not illuminated at night by
street lighting. This can influence
its functioning.
During mounting, proceed as
described below:
Hold the mounting bracket
4
so that it is horizontal (possibly
with a spirit level) against the
wall and mark the fastening
holes.
Now drill the fastening holes
(Ø 6 mm) and push the wall
plugs into the drill holes (Fig. A).
Secure the mounting bracket
onto the wall using the screws
provided.
Open the connection box
2
after you have released the lid
of the connection box with a
cross head screwdriver.
Run the flexible supply line,
type H05RN-F 3G 1.0 mm
2
,
through the cable gland
3
and into the connection box.
The length for the flexible
supply line should not exceed
2.5 m. Fix the connection ca-