background image

VCMA Condensate Pump Series

OWNER'S MANUAL

English

EN

This pump automatically removes condensate water that drips from an air conditioner evaporator coil, 
refrigeration equipment coil, condensing furnace, or condensing boiler. The pump is controlled by a float 
switch mechanism, which automatically starts and stops the pump. 
Some models also include a high-water level switch, which opens a 
thermostat circuit when the pump reservoir is full, stopping produc

-

tion of condensate. Alternatively, this switch can be reconfigured to 
close a circuit, which can operate an external alarm or relay, (pur

-

chased separately).
This product is covered by a Limited Warranty for a period of 12 
months from the date of original purchase by the consumer. For 
complete warranty information, refer to 

www.LittleGiant.com

.

Specifications

SAFETY INSTRUCTIONS

Before Getting Started

This equipment should be installed and serviced by technically qualified personnel who are familiar with 
the correct selection and use of appropriate tools, equipment, and procedures. Failure to comply with 
national and local electrical and plumbing codes and within Little Giant recommendations may result in 
electrical shock or fire hazard, unsatisfactory performance, or equipment failure.
Know the product’s application, limitations, and potential hazards. Read and follow instructions carefully to 
avoid injury and property damage. Do not disassemble or repair unit unless described in this manual.
Failure to follow installation or operation procedures and all applicable codes may result in the following 
hazards:

Model 

Volts

HZ

Amps

Watts

Shut Off

VCMA-15

115

60

1.0

60

15’ (4.6 m)

VCMA-20

115

60

1.5

93

20’ (6.1 m)

VCMA-20

230

50/60

0.5

75

17’ (5.2 m)

Risk of death, personal injury, or property damage due to explosion, 
fire, or electric shock.

• Do not use to pump flammable or explosive fluids such as gasoline, fuel oil, kerosene, etc.
• Do not use in explosive atmospheres or hazardous locations as classified by the NEC, ANSI/NFPA70.
• Do not handle a pump or pump motor with wet hands or when standing on a wet or damp surface, or in water.
• When a pump is in its application, do not touch the motor, pipes, or water until the unit is unplugged or electri

-

cally disconnected.

• If the power disconnect is out of sight, lock it in the open position and tag it to prevent unexpected application of 

power.

Содержание VCMA Series

Страница 1: ...l and local electrical and plumbing codes and within Little Giant recommendations may result in electrical shock or fire hazard unsatisfactory performance or equipment failure Know the product s appli...

Страница 2: ...The pump should only be used with liquids compatible with pump component materials If the pump is used with liquids incom patible with the pump components the liquid can cause failure to the electric...

Страница 3: ...ameter maximum tubing or piping to prevent excessive flow back to unit 4 Route outlet tubing straight up not exceeding 75 of total dynamic head capacity of the pump 5 At the top slope discharge line d...

Страница 4: ...age circuit in the event of high water level activating an external alarm or relay purchased separately Use the following proce dure if an NC configuration is required Remove the pump s motor cover 4...

Страница 5: ...mponents follow these steps 1 Disconnect the pump from the power source 2 Remove tank cover assembly from the tank The cover snaps on to the reservoir Pull out on the slot on the long side of the top...

Страница 6: ...vy to operate correctly Check valve stuck or plugged Remove check valve and inspect for proper operation Outlet flow is blocked Check outlet tubing to ensure that it is not kinked or blocked Clear blo...

Страница 7: ...equipos y procedimientos adec uados El hecho de no cumplir con los c digos el ctricos y de plomer a nacionales y locales y con las recomendaciones de Little Giant puede provocar peligros de descarga...

Страница 8: ...r la bomba No use un prolongador La bomba solo se debe utilizar con l quidos compatibles con los materiales que componen la bomba Si la bomba se utiliza con l quidos incompatibles con los componentes...

Страница 9: ...orriente y aseg rela con la abraza dera de manguera no suministrada Utilice 3 8 pulgada de di metro interior m ximo tuber a para evitar un flujo excesivo de vuelta a la unidad 4 Dirija la tuber a de s...

Страница 10: ...raci n 2 El instalador puede reconfigurar este interruptor al terminal NC para cerrar un circuito de voltaje bajo en el caso de nivel de agua alto lo que podr a activar un rel o una alarma externa que...

Страница 11: ...ccionar y limpiar el tanque y otros componentes siga los pasos que se detallan a continu aci n 1 Desconecte la bomba de la fuente de alimentaci n 2 Quite el conjunto de la cubierta del tanque La cubie...

Страница 12: ...salida est bloqueado Verifique la tuber a de salida para asegurarse de que no est retorcida ni bloqueada Despeje la tuber a bloqueada de lodo y residuos Limpie la tuber a de entrada y de salida El imp...

Страница 13: ...es recommandations de Little Giant pourrait mener une lectrocution ou un incendie une mauvaise performance ou une d faillance de l quipement Lisez et suivez attentivement les instructions pour viter t...

Страница 14: ...e ce soit Il peut uniquement tre raccourci si cela est n cessaire pour le faire rentrer dans le panneau de commande Toute pis sure entre la pompeet le panneau de commandedoit tre r alis edans unebo te...

Страница 15: ...rieur maximum tubulure ou tuyauterie pour viter un coulement excessif de retour l unit 4 Acheminez la tubulure de sortie de la pompe vers le haut Ne d passez pas 75 de la charge hydraulique gal h de...

Страница 16: ...ompe La pompe doit tre connect e ou branch e sur son propre circuit sans autre prise ou quipement sur la ligne du circuit Ne le raccordez pas un ventilateur ou tout dispositif fonctionnant par inter m...

Страница 17: ...d activer une alarme ou un relais externe vendus s par ment Utilisez la proc dure suivante si une configuration NC est requise Retirer le couvercle du moteur de la pompe 4 Soutenir l interrupteur et p...

Страница 18: ...posants suivez ces tapes 1 D branchez l alimentation de la pompe 2 Retirez l ensemble de capot du r servoir Le capot se fixe au r servoir par pression Tirez sur la fente situ e sur le c t long de la p...

Страница 19: ...elle n est pas coud e ou obstru e Nettoyez la boue et les d bris de tout tuyau obstru Nettoyez la tuyauterie d entr e et de sortie La roue de la pompe ne tourne pas Nettoyez toute obstruction dans le...

Страница 20: ...ic Co Inc Oklahoma City OK 73157 2010 800 701 7894 littlegiant com Pour l aide technique entrez s il vous pla t en contact Form 998086 R v 002 03 20 Droits d auteur 2020 Franklin Electric Co Inc Tous...

Отзывы: