background image

INTRODUCTION

EN

This instruction sheet provides you with the information required to safely own and 

operate your Little Giant pump. Retain these instructions for future reference.
The Little Giant pump you have purchased is of the highest quality workmanship 

and material, and has been engineered to give you long and reliable service. 

Little Giant pumps are carefully tested, inspected, and packaged to ensure safe 

delivery and operation. Please examine your pump carefully to ensure that no 

damage occurred during shipment. If damage has occurred, please contact the 

place of purchase. They will assist you in replacement or repair, if required.

READ THESE INSTRUCTIONS CAREFULLY BEFORE ATTEMPTING TO 

INSTALL, OPERATE, OR SERVICE YOUR LITTLE GIANT PUMP. KNOW 

THE PUMP’S APPLICATION, LIMITATIONS, AND POTENTIAL HAZARDS. 

PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY 

INFORMATION. FAILURE TO COMPLY WITH THESE INSTRUCTIONS 

COULD RESULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE!

DESCRIPTION

Little Giant submersible sump and sewage pumps are recommended for use 

in basins or lift stations and are suitable for pumping effluent, wastewater, and 

other non-explosive, non-corrosive liquids. The pumps have 2” spherical solids 

handling capability. Accessories such as basins, check valves, and covers 

are available through your Little Giant dealer.

SPECIFICATIONS

Discharge Size:

 

2” NPT vertical

Intake Size:

 2” 

opening

Horsepower:

 

ES40 = 4/10, ES50 = 1/2, ES60 = 6/10

Pump Housing:

 Cast 

iron

Volute: 

Cast iron

Impeller:

 

ES40, ES50: Plastic vortex design

 

ES60: Cast iron

Motor:

 

Single phase permanent split capacitor with automatic 

reset thermal overload protection

Hardware:

 

300 Series stainless steel

Bearings:

 

Ball, top and bottom

Pump Shaft Seal:

 

Stationary carbon with Nitrile boot and rotating ceramic 

seat

Power Cord:

 

16 AWG 3-conductor, copper, stranded, 10’ or 20’ length

Cooling:

 

The motor housing contains oil to cool the motor and to 

lubricate bearings and seals. These pumps are capable 

of operating with the motor housing partially exposed 

for extended periods, providing sufficient motor cooling 

and bearing lubrication. However, for the best cooling 

and  longest motor life, the liquid level being pumped 

should normally be above the top of the cast iron motor 

housing.

SAFETY GUIDELINES

WARNING: RISK OF ELECTRIC SHOCK.

 This pump is supplied with a ground-

ing conductor and grounding-type attachment plug. To reduce the risk of electric 

shock, be certain that it is connected to a properly grounded, grounding-type 

receptacle. 
Your pump is equipped with a 3-prong electrical plug. The third prong is to 

ground the pump to prevent possible electrical shock hazard. Do not remove 

the third prong from the plug. A separate branch circuit is recommended. Do not 

use an extension cord.
When a pump is in a basin or lift station, do not touch motor, pipes, or water 

until unit is unplugged or shut off. If shut-off box is not accessible, call the electric 

company to shut off service to the house, or call your local fire department for 

instructions. Failure to follow this warning can result in fatal electrical shock. Do 

not modify the power cord except to shorten it to fit into a control panel. Any 

splice between the pump and the control panel must be made within a junction 

box and mounted outside of the basin, and comply with the National Electrical 

Code. Do not use the power cord for lifting the pump.
The pump motor is equipped with an automatic resetting thermal protector and 

may restart unexpectedly. Protector tripping is an indication of motor overloading 

as a result of excessively high or low voltage, inadequate wiring, incorrect motor 

connections, or a defective motor or pump.
  1.  Read all instructions and safety guidelines thoroughly. Failure to follow the 

guidelines and instructions could result in serious bodily injury and/or prop-

erty damage.

  2.  DO NOT USE TO PUMP FLAMMABLE OR EXPLOSIVE FLUIDS SUCH AS 

GASOLINE, FUEL OIL, KEROSENE, ETC. DO NOT USE IN EXPLOSIVE 

ATMOSPHERES OR HAZARDOUS LOCATIONS AS CLASSIFIED BY NEC, 

ANSI/NFPA70. FAILURE TO FOLLOW THIS WARNING CAN RESULT IN 

PERSONAL INJURY AND/OR PROPERTY DAMAGE.

  3.  During normal operation the pump is immersed in water. Also, during rain 

storms, water may be present in the surrounding area of the pump. Use cau-

tion to prevent bodily injury when working near the pump:

  a. Remove the plug from the receptacle before touching, servicing, or 

repairing the pump.

1

ES40D, ES40W, ES40M
ES50D, ES50W, ES50M
ES60D, ES60W, ES60M

U.S. Patent 6,867,383

Franklin Electric Co., Inc.

P. O. Box 12010

Oklahoma City, OK 73157-2010

405.947.2511 • Fax: 405.947.8720

www.LittleGiantPump.com

[email protected]

Dimensions/Dimensions/Dimensiones

MODEL

MODÈLE

MODELO

LENGTH

inches

(cm)

WIDTH

inches

(cm)

HEIGHT

inches

(cm)

ON LEVEL

inches

(cm)

OFF LEVEL

inches

(cm)

ES40M/

ES50M

10.7 

(27.2)

7.6

(19.3)

14.4

(36.6)

N/A

N/A

ES40W/

ES50W

10.7

(27.2)

9.2

(23.4)

14.4

(36.6)

17.0

(43.2)

10.0

(25.4)

ES40D/

ES50D

10.7 

(27.2)

10.5

(26.7)

14.4

(36.6)

15.0

(38.1)

5.0

(12.7)

ES60M

12.3 

(31.2)

8.7

(22.1)

14.8

(37.6)

N/A

N/A

ES60W

12.3 

(31.2)

10.3

(26.2)

14.8

(37.6)

17.5

(44.5)

10.5

(26.7)

ES60D

12.3 

(31.2)

11.6

(29.5)

14.8

(37.6)

15.5

(39.4)

5.5

(14.0)

Figure 1

Содержание ES40D

Страница 1: ...ed to a properly grounded grounding type receptacle Your pump is equipped with a 3 prong electrical plug The third prong is to ground the pump to prevent possible electrical shock hazard Do not remove the third prong from the plug A separate branch circuit is recommended Do not use an extension cord When a pump is in a basin or lift station do not touch motor pipes or water until unit is unplugged...

Страница 2: ...to basin until pump starts 5 Be sure gate valve in discharge line is open 6 Allow pump to operate through several on off cycles MODEL NO LISTING HP VOLTS SOLIDS SIZE dia in AMPS WATTS GPM HEAD SHUT OFF P S I POWER CORD ft WT lbs 5 10 15 20 ES40 CSA cCSAus 4 10 115 2 7 5 760 95 60 22 0 18 7 8 10 55 ES50 CSA cCSAus 1 2 115 2 11 4 1180 120 85 48 12 22 9 5 10 55 ES60 CSA cCSAus 6 10 115 2 10 3 1060 15...

Страница 3: ...rme au Code national de l électricité Ne pas soulever la pompe à l aide du fil d alimentation Le moteur de la pompe est pourvu d un dispositif de protection thermique à démarrage automatique elle peut redémarrer à tout moment Le déclenche ment du dispositif de protection indique une surchauffe du moteur provoquée par un voltage excessif ou insuffisant un câblage non approprié des erreurs de raccor...

Страница 4: ...rer le fusible ou déclencher le disjoncteur NETTOYAGE DE LA TURBINE ET DE LA VOLUTE 1 Enlever les vis qui retiennent le grillage à la volute et la volute au boîtier du moteur 2 Retirer la volute et nettoyer la turbine ainsi que le passage de la volute Éviter d utiliser de puissants solvants sur la turbine 3 Veillez à ce que la turbine tourne librement une fois le nettoyageterminé 4 MISE EN GARDE L...

Страница 5: ...BS de cloruro polivinílico PVC o de acero gal vanizado Para conectar el tubo plástico a la bomba se requieren adaptadores apropiados La bomba debe colocarse en una superficie dura y nivelada No la coloque nunca directamente sobre superficies de arcilla tierra o grava Debe utilizarse una válvula de retención en el tubo de descarga para evitar el reflujo en el dique seco La válvula de retención debe...

Страница 6: ...ncuentre instalada correctamente Check valve stuck or plugged Soupape d arrêt bloquée ou obstruée Válvula de retención atorada u ocluída Remove check valve and inspect for proper operation Démonter et vérifier la soupape d arrêt pour un bon fonc tionnement Quite la válvula de retención y verifique que funcione debidamente Lift too high for pump Aspiration trop puissante pour la pompe Altura de imp...

Страница 7: ...d for continuous pumping of suitable liquids above 140 F 8 if cord cut off to a length less than three feet 9 if pump has been dismantled by customer Authorized Little Giant service stations only can dismantle pump for field service RETURN OR REPLACED COMPONENTS Any item to be replaced under the Warranty must be returned to LITTLE GIANT at Oklahoma City OK or such other place as LITTLE GIANT may d...

Страница 8: ...IA LIMITADA SUMIDERO EFLUENTES Y AGUAS RESIDUALES RESIDENCIALES Las bombas Little Giant de las aguas residuales de la serie ES40 ES50 y ES60 se recomiendan para el uso en colectores de aceite los lavabos o las estaciones de la elevación y convenientes para el drenaje de bombeo del sótano riegan efluente las aguas residuales y el otro inexplosible anticorrosivo líquidos no abrasivos no sobre 140 F ...

Отзывы: