background image

1

INTRODUCTION

EN

This instruction sheet provides you with the information required to safely own and 

operate your Little Giant pump. Retain these instructions for future reference.
The Little Giant pump you have purchased is of the highest quality workmanship 

and material, and has been engineered to give you long and reliable service. 

Little Giant pumps are carefully tested, inspected, and packaged to ensure safe 

delivery and operation. Please examine your pump carefully to ensure that no 

damage occurred during shipment. If damage has occurred, please contact the 

place of purchase. They will assist you in replacement or repair, if required.

READ THESE INSTRUCTIONS CAREFULLY BEFORE ATTEMPTING TO 

INSTALL, OPERATE, OR SERVICE YOUR LITTLE GIANT PUMP. KNOW 

THE PUMP’S APPLICATION, LIMITATIONS, AND POTENTIAL HAZARDS. 

PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY 

INFORMATION. FAILURE TO COMPLY WITH THESE INSTRUCTIONS 

COULD RESULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE!

SAFETY GUIDELINES

WARNING:

 To reduce the risk of electrical shock, remove plug from outlet 

before servicing this pump.
Check local electrical and building codes before installation. The installation 

must be in accordance with their regulations.
During normal operation the sump pump is immersed in water. Also, during rain 

storms, water may be present in the surrounding area of the pump. Use caution 

to prevent bodily injury when working near the pump. Disconnect electrical 

power prior to touching, servicing, or repairing the pump. To minimize possible 

fatal electrical shock hazard, use extreme care when changing fuses. Do not 

stand in water while changing fuses or insert your finger into the fuse socket.
Do not operate the pump in a dry sump. This will cause the pump to become 

extremely hot, causing burns if touched and/or damage to the pump.
Do not oil the motor. The pump housing is sealed. A high-grade dielectric oil 

devoid of water has been put into the motor housing at the factory. Use of other 

oil could cause serious electric shock and/or permanent damage to the pump. 
This pump’s motor housing is filled with a dielectric lubricant at the factory for 

optimum motor heat transfer and lifetime lubrication of the bearings. Use of any 

other lubricant could cause damage and void the warranty. This lubricant is 

non-toxic; however, if it escapes the motor housing, it should be removed from 

the surface quickly by placing newspapers or other absorbent material on the 

water surface to soak it up, so aquatic life is undisturbed.
In any installation where property damage and/or personal injury might result from 

an inoperative or leaking pump due to power outages, discharge line blockage, or 

any other reason, a backup system(s) and/or alarm should be used.

ELECTRICAL CONNECTIONS

WARNING:

 Risk of electric shock. This pump is supplied with a grounding 

conductor and grounding-type attachment plug. To reduce the risk of electric 

shock, be certain that it is connected only to a properly grounded, grounding-

type receptacle.
Your pump is supplied with a 3-prong electrical plug. The third prong is to 

ground the pump to prevent possible electric shock hazard. Do not remove the 

third prong from the plug. A separate branch electrical circuit is recommended. 

Do not use an extension cord.

INSTALLATION

  1.  Clean any debris from sump pit and set pump in center of pit. A solid bottom 

will prevent clogging of the pump from sand and dirt. 

 2.  Connect discharge piping and run it to the nearest sewer or surface outlet. 

Use pipe joint compound at all connections. Sump pumps can be piped 

to discharge into the house drainage system, to a dry well, splash block 

or to a storm drain, depending on local plumbing codes. The discharge 

pipe should be as short as possible and contain as few elbows as possible. 

The dischargepipeshouldbe thesamediameterasthe dischargesizetoreduce 

pipe friction losses. Smaller pipe will restrict capacity and reduce pump 

performance. The sump pump comes with 1-1/2” (3,8 cm) female pipe 

thread discharge, and 1-1/4” (3,2 cm) FNPT reducing bushing.

 3.  Always install a union in the discharge line, just above the sump pit to allow 

for easy removal of the pump for cleaning or repair.

 4.  In situations where the piping is long, the vertical discharge is above 7 

(2,1 m) or 8 (2,4 m) feet, or a small pit has been provided, use of a check 

valve is recommended to prevent backflow of water into the sump. When 

a check valve is used, drill a relief hole [1/8” (0,32 cm) or 3/16” (0,48 cm) 

diameter] in the discharge pipe. This hole should be located below the 

floor line between the pump discharge and the check valve. Unless such a 

relief hole is provided, the 

pump could air lock and 

will not pump water even 

though it will run.

 5. Tape pump and switch 

cords to discharge line 

with electrician’s tape. 

This will protect the cord 

from damage and will 

prevent the power cords 

from interfering with 

float.

 6. TEST PUMP AFTER ALL 

CONNECTIONS HAVE 

BEEN MADE. Run water 

into sump. Do not attempt 

to operate the pump 

without water; this will 

damage the seals and 

bearings and could result 

in permanent damage 

to the pump. Fill sump to 

normal ON level and allow pump to remove to the normal OFF level (Figure 2.)

 7.  Place cover over sump. This cover will prevent solid debris from filling the 

pit, prevent odors, and guard against accidental injury.

WARNING:

 Always disconnect the electrical power before touching the pump 

or discharge when water is present in the sump. Failure to do so can result in 

hazardous electrical shock.

INTRODUCTION

FR

Cette feuille d’instructions vous fournit les informations nécessaires pour 

entretenir et faire fonctionner votre produit Little Giant. Conserver ces directives 

afin de pouvoir les consulter plus tard.
Le produit Little Giant que vous avez acheté a été soigneusement fabriqué avec 

des matériaux de la plus haute qualité et a été conçu pour durer longtemps 

et offrir un service fiable. Les produits Little Giant sont soigneusement testés, 

inspectés et emballés afin d’en assurer la sécurité de fonctionnement et une 

livraison en bonne condition. Vérifier attentivement le produit afin de vous 

assurer qu’il n’a pas été endommagé pendant le transport. S’il est endommagé, 

veuillez contacter l’entreprise qui vous l’a vendu. Si une réparation ou un 

remplacement est requis, elle vous prêtera assistance.

LIRE ATTENTIVEMENT CES DIRECTIVES AVANT DE PROCÉDER À 

L’INSTALLATION, À L’UTILISATION OU À L’ENTRETIEN DU PRODUIT 

LITTLE GIANT. SE FAMILIARISER AVEC LES APPLICATIONS, LES LIMITES 

ET LES RISQUES POTENTIELS DU PRODUIT. ASSURER SA PROPRE 

PROTECTION ET CELLE DES AUTRES EN SUIVANT TOUTES LES RÈGLES 

DE SÉCURITÉ. LE NON-RESPECT DE CES DIRECTIVES PEUT ENTRAÎNER 

DES BLESSURES ET/OU DES DOMMAGES MATÉRIELS!

Franklin Electric Co., Inc.

P. O. Box 12010

Oklahoma City, OK 73157-2010

405.947.2511 • Fax: 405.947.8720

www.LittleGiantPump.com

[email protected]

STOCK NO.

LA RÉSERVE PAS.

ABASTEZCA NUMBER 

3P641A

3P639A

3P642B

MODEL NO. 

NÛ DU MODÈLE

NUMERO DE MODELO

8-CBA

6-CIA

8-CIM

For automatic pumps, install plug with vent tube 
down.
Pour pompes automatiques, le bouchon doit être 
installé avec le tuyau de vent en bas.
Para bombas automaticas: La instalacion correcta 
del tapon es conel tubo de aspiracoin hacia abajo

FIGURE 2 - TYPICAL INSTALLATION • 
INSTALLATION TYPE • INSTALACION TIPICA

FIGURE 1

Отзывы: