INTRODUCTION

EN

This instruction sheet provides you with the information required 
to safely own and operate your Little Giant product. Retain these 
instructions for future reference.
The Little Giant product you have purchased is of the highest 
quality workmanship and material, and has been engineered to 
give you long and reliable service. Little Giant products are care-
fully tested, inspected, and packaged to ensure safe delivery and 
operation. Please examine your item(s) carefully to ensure that 
no damage occurred during shipment. If damage has occurred, 
please contact the place of purchase. They will assist you in 
replacement or repair, if required.

READ THESE INSTRUCTIONS CAREFULLY BEFORE 
ATTEMPTING TO INSTALL, OPERATE, OR SERVICE 
YOUR LITTLE GIANT PRODUCT. KNOW THE PRODUCT’S 
APPLICATION, LIMITATIONS, AND POTENTIAL HAZARDS. 
PROTECT YOURSELF AND OTHERS BY OBSERVING ALL 
SAFETY INFORMATION. FAILURE TO COMPLY WITH THESE 
INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/
OR PROPERTY DAMAGE!

DESCRIPTION

The FP series Flex Pumps provide circulating, oxygenated water 
to features such as ponds, fountains, displays, waterfalls, and 
filter systems.

SAFETY GUIDELINES

WARNING: RISK OF ELECTRICAL SHOCK. PLEASE OBSERVE 
THE FOLLOWING SAFETY GUIDELINES.
WARNING:

 This pump has not been investigated for use in swim-

ming pools.
This pump uses a grounding conductor and a grounding-type 
attachment plug. To reduce the risk of electrical shock, connect the 
pump only to a properly grounded, grounding-type receptacle.
Employ a qualified, licensed electrician to provide electrical 
power.

Check product label for proper voltage required. Do not connect 
to voltage other than that shown.
To comply with the National Electric Code (NEC) and to reduce 
the risk of electric shock, connect the pump only to an outlet pro-
tected by a ground fault circuit interrupter (GFCI).
Check the power cord regularly to ensure that it is in good condi-
tion, with no nicks or cuts.
Do not lift the pump by its power cord.
Do not let the pump freeze during colder temperatures. This can 
cause cracking or distortion that will damage the pump. See the 
MAINTENANCE section for storage instructions.
Do not operate the pump dry. This will cause the pump to become 
extremely hot, causing burns if touched and/or damage to the 
pump.
Do not use to pump water hotter than 95°F (35°C). 

INSTALLATION AND OPERATION

WARNING:

 Ensure that the installation conforms with all local and 

state electric codes. 

NOTE:

 The pump has thermal overload protection. If it becomes 

overheated it will shut off. See the Troubleshooting section to 
restart.

In-Water (Submersible) Installation 

Refer to Figure 1, Figure 2, and the following steps to configure 
the pump for in-water (submersible) use:
 1.  Locate the connection box in a dry area at least 6-1/2 feet (2 

meters) from the edge of the water.

 2.  Place the pump into the water on a flat surface, ensuring that 

the pump is completely submersed and that the volute is filled 
with water.

   

CAUTION:

 If the surface is dirt or sand, place the pump on a 

flat object such as a brick or stone to prevent clogging. For 
best results, place the pump into a skimmer. 

   

CAUTION:

 Ensure that the water level does not go below 

25cm (FP1, FP2, and FP3) or 30cm (FP6 and FP9).

 3. 

FP1, FP2, and FP3 ONLY:

 The discharge can be configured 

to point up or to the side, depending on the application. To 
redirect the discharge, loosen the four clip screws (1), turn the 
motor housing (9) until the discharge is in the desired position, 
and tighten the screws.

 4. Make all necessary intake and discharge connections. 

NOTE:

 Use a pre-filter on the intake for added protection from 

clogging.

FP SERIES FLEX PUMP • 

POMPE FLEX DE 

SÉRIE FP • SERIE FP

BOMBA FLEXIBLE

1

Franklin Electric Co., Inc.

P. O. Box 12010

Oklahoma City, OK 73157-2010

888.956.0000 • Fax: 405.947.8720

www.LittleGiantWater.com

[email protected]

Min. 6.5 ft. (2m)

Min. 10 in. (25cm)

FIGURE 1

Min. 6.5 ft. (2m)

Min. 10 in. (25cm)

FIGURE 2

Содержание 566132

Страница 1: ...the power cord regularly to ensure that it is in good condi tion with no nicks or cuts Do not lift the pump by its power cord Do not let the pump freeze during colder temperatures This can cause crac...

Страница 2: ...cord is not replaceable If it becomes damaged the entire pump must be replaced Alteration of the power cord will void the warranty Filter M Min 6 5 ft 2m FIGURE 3 D S FIGURE 4 NOTE How often the pump...

Страница 3: ...o the pump and check for proper operation Refer to the Troubleshooting section if the pump is not operat ing properly 1 2 4 5 6 7 8 3 9 FP3 only FP3 seulement FP3 s lo 10 12 13 11 14 FIGURE 5 FP1 FP2...

Страница 4: ...lever la pompe par son cordon d alimentation Ne pas laisser la pompe geler lorsque la temp rature descend sous le point de cong lation Le gel risque de fissurer ou de d former la pompe et de l endomma...

Страница 5: ...lign s avec les deux goupilles 8 du bo tier 10 V rifier que l ensemble du rotor tourne facilement 11 l aide des quatre vis 3 fixer la volute 4 au bo tier du moteur en s assurant que le joint torique r...

Страница 6: ...ctrico 3 Verifique el voltaje apropiado requerido en la etiqueta de la bomba No la conecte a un voltaje distinto del indicado 4 Para cumplir con el C digo el ctrico estadounidense NEC por sus siglas e...

Страница 7: ...asegur ndose de que los dos agujeros 5 de la placa queden alineados con las dos clavijas 8 del alojamiento 10 Compruebe que el conjunto de rotor gire con facilidad 11 Con los cuatro tornillos 3 insta...

Страница 8: ...or assembly FP9 166059 3 7 10 O ring and screw kit All models 166060 TABLE 2 7 Instale el anillo t rico en el alojamiento del motor 8 Deslice con cuidado el conjunto de rotor en el alojamiento del mot...

Страница 9: ...ouant avec le tube de refoulement ouvert Desconecte el cord n el ctrico Saque el aire sumergiendo la bomba en una posici n inclinada y sacudi ndola con el tubo de descarga abierto Suction screen is cl...

Страница 10: ...o have other rights which vary from state to state and country to country The National Electric Code in the USA and similar codes in other countries require a Ground Fault Circuit Interrupter GFCI to...

Страница 11: ...por un representante de Little Giant o avisarle a la f brica de los detalles del problema para que la f brica disponga de las acciones necesarias y resuelva el reclamo de la garant a DESAUTORIZACION...

Страница 12: ...Pour l aide technique entrez s il vous pla t en contact 1 888 956 0000 Para partes o la reparaci n por favor p ngase en contacto 1 888 572 9933 Para la ayuda t cnica por favor p ngase en contacto 1 8...

Отзывы: