background image

INTRODUCTION

EN

This instruction sheet provides you with the information required to 

safely own and operate your product. Retain these instructions for 

future reference.
The product you have purchased is of the highest quality workman-

ship and material, and has been engineered to give you long and 

reliable service. This product has been carefully tested, inspected, 

and packaged to ensure safe delivery and operation. Please exam-

ine your item(s) carefully to ensure that no damage occurred dur-

ing shipment. If damage has occurred, please contact the place of 

purchase. They will assist you in replacement or repair, if required.
READ THESE INSTRUCTIONS CAREFULLY BEFORE 

ATTEMPTING TO INSTALL, OPERATE, OR SERVICE YOUR 

PRODUCT. KNOW THE PRODUCT’S APPLICATION, 

LIMITATIONS, AND POTENTIAL HAZARDS. PROTECT 

YOURSELF AND OTHERS BY OBSERVING ALL SAFETY 

INFORMATION. FAILURE TO COMPLY WITH THESE 

INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/

OR PROPERTY DAMAGE.

SAFETY GUIDELINES

WARNING: Your pump is an electrical product and caution should 

be used when handling the pump or its electrical cord. Small children 

or pets may require restraining devices to prevent them from entering 

wet areas surrounding the pump or its power supply connections.
  1. This product is provided with a three-prong grounding plug, to 

reduce the risk of electrical shock. When pump is in operation, 

make sure it is properly connected to grounded outlet.

 2. Never pump chemicals or corrosive liquids with this pump. 

This could damage the integrity of the enclosure and cause an 

electrical short.

  3.  Do not run this pump dry. Running this pump without water may 

damage the integrity of the enclosure and cause electrical short.

  4.  If service is required, proceed carefully. The pump and surrounding 

areas may be covered with water. Never plug or unplug the device 

while standing on wet or damp surfaces. If necessary, remove 

power at the breaker panel or have certified electrician remove 

power before attempting to service. Serious or fatal shocks could 

result if proper procedures are not followed:

  a. Disconnect the power at the main electrical service box, by 

switching the appropriate circuit breaker or removing fuse. In 

applications where screw type fuses are used, remove only 

with one hand while other hand or torso are free from contact 

with anything. Do not stand in water and do not touch any 

other conductive surfaces.

  b. Remove pump cord plug only after the power to the supply 

outlet has been removed. See Service Instructions before 

proceeding.

 5. Remove pump when conditions will cause water to freeze. 

Freezing water may result in cracking or distortions and could 

result in possible electrical short or sensor failure.

 6. Never pump gasoline or other low flash point fluids with this 

pump. Explosion or fire could result.

SPECIFICATIONS

VOLTS AMPS WATTS

GALLONS PER HOUR

1'

3'

5'

7'

9'

115

.8

45

500

395

293

184

82

CAPACITY SIZING INFORMATION

The 500 GPH performance was obtained through a one inch I.D. 

tube, with friction losses neglected. Using a 5/8" garden hose, 50 

feet long, reduces this performance to approximately 200 gallons 

per hour due to friction losses in the garden hose.

INSTALLATION

 1. Be certain electrical outlet to be used meets the requirements 

of the National Electric Code, as well as local electrical codes, 

including grounding, and GFCI protection. Also verify that outlet 

is properly sized and located for this pump. Your installation 

may require a certified electrician or plumber. See ElECTRICAl 

CoNNECTIoNS section.

  2.  If necessary, check your local plumbing codes to verify that final 

installation will be in compliance with their requirements.

  3.  Remove pump from carton.
  4.  Connect tubing to discharge thread.
  5.  Place pump in water, sensors pointed down (Fig. 1)

ELECTRICAL CONNECTIONS

WARNING: Always disconnect the electrical power before touching 

the pump, discharge, or electrical plug when water is present in 

the area. Failure to do so can result in serious bodily injury and/or 

property damage. Always connect pump to grounded receptacle 

(see SAFETY GUIDElINES section).
 1. Your pump is supplied with a three-prong electrical plug. The 

third prong is to ground the pump to prevent possible electric 

shock hazard. Do not remove the third prong from the plug.

 2. A separate branch electrical circuit is recommended. The 

electrical power required is 5 amps at 115 VAC.

 3. Be sure that the electrical connection cannot be reached by 

rising water. Under no circumstances should the connection be 

located where it may become flooded or submerged by water.

  4. Test the pump after all electrical connections have been made. 

Run water into the area where the pump is to be placed. Do not 

attempt to operate the pump without water; this could result in 

permanent damage to the pump. Fill the area to a normal oN 

level and allow the pump to remove water to a normal oFF level.

500-APCP

HYDROPONIC PUMP

POMPE HYDROPONIqUE 

BOMBA HIDROPóNICA

Fig. 1

Sensors

Capteurs

Sensores

Franklin Electric Co., Inc.

P. o. Box 12010

oklahoma City, oK 73157-2010

888.956.0000

www.lg-outdoor.com

1

Jolie 

Products, 

Inc

Содержание 500-APCP

Страница 1: ...the supply outlet has been removed See Service Instructions before proceeding 5 Remove pump when conditions will cause water to freeze Freezing water may result in cracking or distortions and could re...

Страница 2: ...fs Cela pourrait causer des dommages au b ti et causer un court circuit 3 viter de faire fonctionner la pompe sec Il pourrait en r sulter des dommages au b ti ou un court circuit 4 Faire preuve de pru...

Страница 3: ...IDAD ADVERTENCIA Lea cuidadosamente estas instrucciones De no seguirlas podr a resultar en da o personal serio y o da os a la propiedad La bomba es un aparato el ctrico y se debe usar precauci n al ma...

Страница 4: ...A medida que el agua sube alrededor de la cubierta del interruptor un flotador sube y activa el interruptor de la bomba la bomba debe encenderse cuando el nivel del agua alcanza un nivel de 2 La bomb...

Страница 5: ...Pieza DESCRIPTION Nomenclature Descripci n Quantity Quantit Cantidad 1 924050 O Ring nitrile Joint torique nitrile Sello anular de nitrilo 1 2 599093 Impeller assembly Bloc turbine Conjunto del impul...

Страница 6: ...tion plusieurs fois pour vacuer l air de la pompe S il y a une soupape d arr t percer un trou de 3 16 po dans letuyau d coulement environ 2 po au dessus des connexions d coulement Desconecte la electr...

Страница 7: ...representatives or any other parties do not constitute warranties shall not be relied upon by the user and are not part of the contract for sale Seller s and the Company s only obligation and buyer s...

Страница 8: ...decuado mantenimiento o reparaci n inadecuados da o o siniestro en exceso de las m ximas recomendadas que se establecen en las instrucciones del producto 3 Cualquier producto que sea operado con cualq...

Отзывы: