background image

INSTALLATION

Physical Installation

3

INSTALLATION

Physical Installation

1. Do not plug in the pump until all plumbing connections are complete and pump is secure.
2. Connect a garden hose using the 3/4" garden hose adapter or connect 1" MNPT threaded pipe or 

hose directly to the 1" FNPT discharge port.
• If using the 3/4" garden hose adapter, performance will be reduced approximately 15%.
• If flexible vinyl tubing is used, a clamp can be used on the tubing to restrict the flow.

3. Place the pump vertically on a solid surface in the water to be removed. 

• The water should be at least 3/4" deep.
• The pump should be totally submerged for proper cooling when operated for extended periods.
• Never place the pump directly on clay, earth, or gravel surfaces to prevent damage and pump 

failure. Place the pump on a flat surface such as a piece of wood or metal to prevent it from 
being clogged.

4. Position the free end of the hose or pipe where the water is to be relocated.
5. For water containing high mineral content (hard water) or metals, use a pump with an attached sac

-

rificial anode to prevent "galvanic corrosion”.
• Contact your local distributor for the model SA-1 by Little Giant.

Risk of bodily injury, electric shock, or equipment damage.

This equipment must not be used by children or persons with reduced physical, sensory or mental abilities, or lacking in experi

-

ence and expertise, unless supervised or instructed. Children may not use the equipment, nor may they play with the unit or in 

the immediate vicinity.

Equipment can start automatically. Always unplug the pump power cord and disconnect the electrical power before servicing the 

pump or switch.

An inoperative or malfunctioning pump could lead to flooding, resulting in personal injury or property damage.

In applications where property damage and/or personal injury might result from an inoperative or leaking pump due to power 

outages, discharge line blockage, or any other reason, an automatic back-up system and/or an alarm should be installed.

Do not run the pump dry. If run dry, the surface temperature of the pump will rise to a high temperature that could cause skin 

burns if touched, and will cause serious damage to the pump.

Do not oil the motor. This unit is permanently lubricated. Oiling is not required. The pump’s motor housing is sealed. Do not open 

the sealed portion of the unit or remove housing screws. Opening the motor housing could cause serious electric shock and/or 

permanent damage to the pump.

The pump has been evaluated for use with water only. Pump should only be used with liquids compatible with pump component 

materials. If the pump is used with liquids incompatible with the pump components, the liquid can cause failure to the electrical 

insulation system resulting in electrical shock.

Operation of this equipment requires detailed installation and operation instructions provided in this manual for use with this 

product. Read entire manual before starting installation and operation. End User should receive and retain manual for future use.

Keep safety labels clean and in good condition.

If an accessory float switch or other liquid level control is installed, refer to manufacturer’s instructions. Failure to install control in 

compliance with national and local electrical and plumbing codes and within manufacturer’s recommendations may result in 

electrical shock or fire hazard, unsatisfactory performance, or equipment failure.

Risk of damage to pump or other equipment.

Do not use this pump for pumping sea water, beverages, acids, chemical solutions, or any other liquid that promotes corrosion as 

this can result in damage to the pump.

Do not run pump dry. For optimal cooling and to prolong the motor life, the liquid level being pumped should normally be above 

the top of the pump housing.

This pump is not suitable for pond applications.

Warranty is void if the motor housing cover or power cord have been removed.

Содержание 305624001

Страница 1: ...ping is an indication of motor overloading or overheating This can be caused by application issues such as an obstructed pump impeller pump running dry pump air locked pump short cycling excessively h...

Страница 2: ...sing severe injury or death by electrical shock are present in this unit To reduce risk of electrical shock disconnect power before working on or around the system More than one disconnect switch may...

Страница 3: ...r leaking pump due to power outages discharge line blockage or any other reason an automatic back up system and or an alarm should be installed Do not run the pump dry If run dry the surface temperatu...

Страница 4: ...models are supplied with a stripped wire cord end Power connections must be made within a junction box and must comply with the National Electrical Code Wires are color coded as follows Green yellow...

Страница 5: ...he atmosphere through a breather tube routed through the pump s power cord Non restric tive air flow in the breather tube is required 1 Place the pump in an empty test basin 2 Connect the pump to powe...

Страница 6: ...e of the power cord or stripped end of the power cord 3 Release the bulb to induce suction vacuum 4 Listen for the switch to make a click sound 5 Once the suction vacuum equalizes listen for the diaph...

Страница 7: ...ute to the motor housing with screws 10 Replace the screen onto the volute Risk of severe injury or death by electrical shock high temperatures or pressurized fluids Always unplug the pump power cord...

Страница 8: ...rcuit breaker or replace fuse Defective motor Replace pump Pump will not shut off Liquid inflow matches pump capacity Larger pump required Pump runs but does not dis charge liquid Lift too high for pu...

Страница 9: ...a activaci n del protector t rmico es una indicaci n de sobrecarga o sobrecalenta miento del motor Esto puede deberse a problemas de aplicaci n como un impulsor de la bomba obs truido una bomba que fu...

Страница 10: ...ctrica desconecte la energ a antes de trabajar en el sistema o cerca de l Es posible que sea necesario m s de un interruptor de desconexi n para cortar la energ a del equipo antes de realizarle un man...

Страница 11: ...cionar vac a la bomba Si la hace funcionar vac a la temperatura de la superficie de la bomba aumentar al punto que podr a provocar quemaduras si se la toca y le causar serios da os a su bomba No apliq...

Страница 12: ...ades de 230 V se recomienda un fusible de 5 0 amperios Modelos con cables con extremos pelados Algunos modelos vienen con un extremo del cable pelado Las conexiones de alimentaci n deben reali zarse d...

Страница 13: ...able de alimentaci n de la bomba Es obligatorio que el aire fluya sin restricciones por el tubo de respiraci n 1 Coloque la bomba en un recipiente de prueba vac o 2 Conecte la bomba a una fuente de al...

Страница 14: ...del cable de alimentaci n 3 Libere la pera para provocar la succi n el vac o 4 Escuche que el interruptor haga un clic 5 Cuando la succi n el vac o se iguale escuche para verificar que el interruptor...

Страница 15: ...motor con tornillos 10 Reemplace la pantalla en la voluta Riesgo de lesiones graves o muerte por descarga el ctrica temperaturas elevadas o l quidos presurizados Siempre desenchufe el cable el ctrico...

Страница 16: ...e apaga El flujo de entrada de l quido coincide con la capacidad de la bomba Se requiere una bomba m s grande La bomba fun ciona pero no descarga l quido Elevaci n demasiado alta para la bomba Revise...

Страница 17: ...e et peut red marrer inopin ment Le d clenchement du disjoncteur thermique indique la surcharge ou la surchauffe du moteur Ce d clenchementpeut tre caus par des probl mes d application notammentl obst...

Страница 18: ...ev es susceptibles d entra ner par choc lectrique des blessures graves ou la mort Pour r duire le risque de choc lectrique d branchez l alimentation avant de travailler sur le syst me ou autour de cel...

Страница 19: ...pas faire fonctionner la pompe sec En cas de fonctionnement sec la temp rature la surface de la pompe augmentera un niveau susceptible de causer des br lures cutan es en cas de contact et entra nera...

Страница 20: ...de fils aux extr mit s d nud es Certains mod les sont fournis avec des fils aux extr mit s d nud es Les connexions d alimentation doivent tre r alis es install s dans une bo te de jonction en conform...

Страница 21: ...t dans le cordon d alimentation de la pompe Une a ration non restrictive est n cessaire dans le tube reniflard 1 Placer la pompe dans un bassin d essai vide 2 Raccordez la pompe une alimentation avec...

Страница 22: ...d nud e du cordon d alimentation 3 Rel chez la poire pour provoquer l aspiration le vide 4 Attendez que l interrupteur mette un clic 5 Une fois l galisation r alis e gr ce l aspiration au vide attend...

Страница 23: ...z l cran sur la volute Risque de blessure grave ou de mort par lectrocution temp rature lev e ou liquide sous pression Avant d effectuer des travaux sur la pompe ou l interrupteur vous devez toujours...

Страница 24: ...iquide est adapt aux capac it s de la pompe Une pompe de plus grande taille est n cessaire La pompe fonc tionne mais elle ne refoule pas le liquide La pompe est soulev e trop haut V rifiez le rendemen...

Отзывы: