background image

3

MAINTENANCE AND SERVICING

WARNING

WARNING:

 Before working on the pump or switch, unplug the 

pump power cord, in addition to removing the fuse or shutting off 

the circuit breaker. 
If the pump does not operate properly, consult the Troubleshooting 

table. If the trouble still cannot be found, consult your pump dealer 

or take the pump to a Little Giant authorized service center.

CAUTION:

 DO NOT remove the socket head cap screws (item 

#3, Figure 3). The motor section of your pump is permanently 

lubricated with dielectric oil and is sealed at the factory. Removal 

of these screws by anyone other than an authorized Little Giant 

service center will break the seal and void the warranty.
 1. Remove the 4 screws (item #18, Figure 3) that hold the 

volute to the motor housing, then separate the volute from the 

housing

  2. Clean the impeller and volute passage.
  3. Be sure impeller turns freely.
 4. Attach the volute to the housing and secure it with the 4 

screws.

F

IGURE

 2 - T

YPICAL

 I

NSTALLATION

Gate valve

Check valve

Union

Vent

Discharge

Intake

Caulking hub

Air bleed hole

Float switch 

(optional)

Pump off level

Pump on level

Switch plug 

(optional)

Pump plug

PumpAgents.com - Click here for Pricing/Ordering

PumpAgents.com - Click here for Pricing/Ordering

Содержание 14S-CIM

Страница 1: ...E WARNING RISK OF ELECTRIC SHOCK This pump is supplied with a grounding conductor and or grounding type attachment plug To reduce the risk of electric shock connect it only to a properly grounded grou...

Страница 2: ...al POWER CORD 16 AWG 3 conductor copper stranded 18 AWG 208 240V models COOLING The motor housing contains oil to cool the motor and to lubricate the bearings and seals For the best cooling and longes...

Страница 3: ...oil and is sealed at the factory Removal of these screws by anyone other than an authorized Little Giant service center will break the seal and void the warranty 1 Remove the 4 screws item 18 Figure...

Страница 4: ...4 Figure 3 PumpAgents com Click here for Pricing Ordering PumpAgents com Click here for Pricing Ordering...

Страница 5: ...14 x 1 1 4 2 2 2 2 2 2 2 2 2 11 921104 LOCK WASHER 7 16 2 2 2 2 2 2 2 2 2 12 114101 FLANGE GASKET 1 1 1 1 1 1 1 1 1 13 114038 VOLUTE 14EH 16EH 1 1 1 13 114043 VOLUTE 14S 16S 1 1 1 1 1 1 14 920004 JAM...

Страница 6: ...ow matches pump capacity Larger pump required Defective switch Disconnect switch check with ohmmeter Open infinite resistance closed zero Loose connection in level control wiring Check control wiring...

Страница 7: ...corrosive substances 7 if pump has been used for continuous pumping of suitable liquids above 140 F 8 if power cord has been cut or spliced 9 if pump has been dismantled by customer Dealer only can d...

Страница 8: ...demark of Franklin Electric Co Inc For parts or repair please contact 1 888 572 9933 For technical assistance please contact 1 888 956 0000 www LittleGiantPump com CustomerService WTS fele com 8 PumpA...

Отзывы: