background image

 

PGR-3200 Insulation Monitor

 

Page ii 

 

 

Rev. 3-E-040918 

 
 

 

T

ABLE

 

OF

 C

ONTENTS

 

S

ECTION

 

P

AGE

 

 

General

.......................................................................... 1

 

Operation

...................................................................... 1

 

  2.1  Relay Operating Mode ................................................. 1 
  2.2  Front-Panel Controls .................................................... 1 
   

2.2.1  Reset .................................................................. 1 

   

2.2.2  Test .................................................................... 1 

  2.3  Front-Panel Indication .................................................. 1 
   

2.3.1  Power ................................................................. 1 

   

2.3.2  Insulation Warning........................................... 1 

   

2.3.3  Active ................................................................ 1 

   

2.3.4  Insulation Alarm............................................... 1 

  2.4  Analog Output ............................................................... 1 
  2.5  Remote Reset ................................................................ 1 
  2.6  Remote Test................................................................... 1 

Installation

.................................................................... 3 

  3.1  PGH-5000 and PGH-6000 ........................................... 4 

Technical Specifications

 ............................................ 6 

  4.1  PGR-3200 ...................................................................... 6 
  4.2  PGH High-Tension Couplers ...................................... 7

 

Ordering Information

 ................................................ 7

 

Performance Test

........................................................ 7

 

  6.1  Insulation Test ............................................................... 7 

Appendix A PGR-3200 Revision History

 ........................... 8

 

 

 

L

IST OF

 F

IGURES

 

F

IGURE

 

P

AGE

 

 

PGR-3200 Outline and Mounting Details.................. 2 

Connection Diagram for Ungrounded Systems 

 

Under 1.3 kV ................................................................. 3 

Connection Diagram for Ungrounded 

 

5-kV Systems ................................................................ 3 

PGH-5000 Outline and Mounting 

 

Details ............................................................................ 4 

PGH-6000 Outline and Mounting 

 

Details ............................................................................ 5 

PGA-0510 Analog Ohm Meter ................................... 5 

 

D

ISCLAIMER

 

 

  Specifications  are  subject  to  change  without  notice.  
Littelfuse, Inc. is not liable for contingent or consequential 
damages, or for expenses sustained as a result of incorrect 
application, incorrect adjustment, or a malfunction. 

 

Содержание PGR-3200

Страница 1: ...32 3873 E mail techline littelfuse com www littelfuse com PGR 3200 MANUAL INSULATION MONITOR REVISION 3 E 040918 Copyright 2018 by Littelfuse Inc All rights reserved Document Number PM 1025 EN Printed...

Страница 2: ...PGR 3200 Insulation Monitor Page i Rev 3 E 040918 This page intentionally left blank...

Страница 3: ...gh Tension Couplers 7 5 Ordering Information 7 6 Performance Test 7 6 1 Insulation Test 7 Appendix A PGR 3200 Revision History 8 LIST OF FIGURES FIGURE PAGE 1 PGR 3200 Outline and Mounting Details 2 2...

Страница 4: ...PGR 3200 Insulation Monitor Page iii Rev 3 E 040918 This page intentionally left blank...

Страница 5: ...ng the supply voltage will also reset the PGR 3200 See Section 2 5 2 2 2 TEST All LED s will light and output relays will energize when the TEST button is pressed for at least 8 s 2 3 FRONT PANEL INDI...

Страница 6: ...PGR 3200 Insulation Monitor Page 2 Rev 3 E 040918 FIGURE 1 PGR 3200 Outline and Mounting Details...

Страница 7: ...l 5 L2 N as the neutral terminal Connect terminal 30 to ground For systems up to 1 3 kV connect terminal 2 to one phase on the load side of the starter Connect terminals for latching operation remote...

Страница 8: ...nd mounting details Connect protective ground terminal to ground Connect terminal E to ground or to PGR 3200 terminal 30 which must be grounded Connect terminal M to PGR 3200 terminal 29 PGR 3200 term...

Страница 9: ...PGR 3200 Insulation Monitor Page 5 Rev 3 E 040918 FIGURE 5 PGH 6000 Outline and Mounting Details FIGURE 6 PGA 0510 Analog Ohm Meter...

Страница 10: ...istance Output Relays Warning and Alarm Configuration N O and N C Form C Operating Mode Non Fail Safe UL Contact Rating 5 A 240 Vac resistive 0 28 A 30 Vdc resistive Switching Capacity 1 200 VA Supple...

Страница 11: ...h Tension Coupler PGH 6000 6 kV High Tension Coupler NOTES 1 UL not available for this supply option 6 PERFORMANCE TEST 6 1 INSULATION TEST Perform this test with the starter open and appropriate lock...

Страница 12: ...added REVISION 3 D 111915 SECTION 4 Terminal torque specifications added REVISION 3 D 111915 SECTION 4 Terminal torque specifications added SECTION 5 Ordering information updated REVISION 3 C 080415...