Littelfuse AF0100 Скачать руководство пользователя страница 9

AF0100 Arc-Flash Relay

GENERATOR APPLICATION GUIDE

9

Littelfuse.com/ArcFlash

© 2017 Littelfuse Products

ADVANTAGES OF RESISTANCE GROUNDING FOR GENERATORS

SE-330 Series

 

Neutral-Grounding-Resistor Monito

r

Advanced Neutral-Grounding-Resistor (NGR) 

Monitor with data logging and optional 

communications.

NGR Series

 

Neutral-Grounding-Resistor System

Monitoring-ready NGR packages that speed 

deployment on site.

EL3100 Series

 

Ground-Fault and Phase-Voltage Indication 

Ground-Fault Monitor for ungrounded generators and 

phase-voltage indication for systems up to 600 volts.

NGRM-ENC Series

 

Neutral-Grounding-Resistor Monitor

Enclosure with SE-325 or SE-330 NGR Monitor and 

optional phase voltage, metering, indication and reset.

SE-701 Series

 

Ground-Fault Monitor

Wide-range ground-fault relay, 

especially suitable for rental units.

PGR-4300 Series

 

Generator Ground-Fault Relay

Generator Ground-Fault Relay for solidly 

grounded generators. No CT required.

 Generator ground-fault current can be higher than short-circuit current for solidly grounded generators.

 High-resistance grounding can eliminate the possibility of phase-to-ground arc flash on the first ground fault.

  Continuity of service during a ground fault for applications below 5 kV and with a neutral-grounding resistor (NGR) 

limiting current below 10 A.

  Reduced mechanical and electrical damage resulting from high-current ground faults.

 Eliminate transient overvoltages from ungrounded systems.

 Multiple generators can be grounded at a single point using a zig-zag transformer.

SE-704 Series

 

Earth-Leakage Relay

Earth-Leakage Relay for resistance-

grounded generators.

SE-325 Series

 

Neutral-Grounding-Resistor Monitor

Standard NGR Monitor, ideal for systems with  

let-through currents of 25-A or lower.

Содержание AF0100

Страница 1: ...GENERATOR APPLICATION GUIDE AF0100 ARC FLASH RELAY...

Страница 2: ...ckground 4 Methods 4 GENERATOR PROTECTION USING AF0100 5 Generator To Generator Breaker Connection 5 Transformer Enclosure 5 AF0100 CONNECTION DIAGRAM 6 SENSOR COVERAGE 7 EFFECT OF GENERATOR GROUNDING...

Страница 3: ...r maintenance In many cases arc flash calculations limit burn time to two seconds for workers to get clear of the danger In a generator application the personnel are trapped in the enclosure during an...

Страница 4: ...An instantaneous trip setting that is less than the available arcing current 6 An instantaneous override that is less than the available arcing current 7 An approved equivalent means ANSI Z10 RISK CON...

Страница 5: ...also turn off the generator The latter is usually accomplished by either connecting to the automatic voltage regulator AVR an emergency stop circuit or generator controller Often the voltages require...

Страница 6: ...spaces of mobile gensets PC CONNECTION TRIP OUTPUT 1 TRIP OUTPUT 2 100 240 VAC DC SUPPLY 24 48 VDC SUPPLY DIGITAL INPUTS OUTPUTS UNIT HEALTH AF0100 CONNECTION DIAGRAM Generators are often the last li...

Страница 7: ...sor design can withstand a detected arc flash event Sensor can be installed up to 50 m 164 ft away from relay electrical cable can be cut and easily re terminated in the field Fiber Optic Light Sensor...

Страница 8: ...or three phase fault levels only resulting in mechanical damage during a ground fault even if the fault is not arcing The Littelfuse SE 701 Ground Fault Relay can monitor for a wide range of current l...

Страница 9: ...ult relay especially suitable for rental units PGR 4300 Series Generator Ground Fault Relay Generator Ground Fault Relay for solidly grounded generators No CT required Generator ground fault current c...

Страница 10: ...tic configuration minimize labor costs Seamless to your customer no customer interaction required with arc flash relay We are a global partner for your global business Global certifications Global dis...

Страница 11: ...nit AF0100 Arc Flash Relay Date and Time Synchronize to PC Clock Disabled o Enabled o Disabled Light Sensors Common Settings Light Immunity Lower Limit 10 10 25 klux klux Arc Detection Time Before Tri...

Страница 12: ...ns contact our Technical Support Group 800 832 3873 Specifications descriptions and illustrative material in this literature are as accurate as known at the time of publication but are subject to chan...