Lithonia Lighting DSX0 Скачать руководство пользователя страница 4

        Part    Number:  RJ521357  Rev  A                 

Revision Date: 3-5-13

  Installation Instructions
  DSX0 LED

 

DSX0 LED 1 HS (1 panel) or DSX0 LED 2 HS (2 panels shown) 

1) Remove the screws shown in picture from the light engine and discard.
2) Place a House-side shield on the light engine and align the holes on the shield with the 
holes on the light engine.
3) Assemble the shield to the light engine using the supplied screws.
4) Repeat steps 1-3 as needed.

Accessory:  DSX0HS U (one per light engine)

DSX0 DROP LENS

1) Place drop lens over the light engines and align the holes on the lens with the holes on the 
housing.
2) Fasten using the supplied screws.

DSX WBA (Wall bracket)

1.          CAUTION:  APPLY A CONTINUOUS BEAD OF WEATHER - PROOF CAULKING BETWEEN MOUNTING PLATE AND WALL TO EN-
SURE WEATHER - TIGHT  INTEGRITY  OF  ELECTRICAL  COMPONENTS (see diagram below).
2.  Secure base plate to wall with (4) 1/4" fastener (by others) using the (4) holes located on the outer corners of the base plate.  Check the 
base plate  to confi rm that it is level and plumb in all directions (see diagram below).
3.  Prepare the cover plate by attaching the fi xture's mounting block to the cover plate using (2) 3/8" diameter by 1-1/4" bolts with lockwashers 
by inserting the bolts and washers into the mounting block through the cover plate and thread into the threaded steel bar stock.  Use a  9/16" 
socket or wrench and tighten securely (see diagram below).
4.  Place the curved portion of the cover plate upwards.  Ensure the factory installed gasket is in place on the backside of the cover plate.  Place 
large eyelet of safety cable over the lower bolt.  Secure with provided nut (see diagram below).

5.   Insert  and tighten (4) 3/8" diameter by 1-1/4" stainless steel hex head screws  into the threaded opening of the cover plate by turning 
approximately 6-7 full turns (see diagram above).
6.  To prepare fi xture for installation,  open doorframe by loosening the (2) captive screws using 3/16" allen wrench.  (See Figure 3)
7.  Pull the wires from the fi xture through the mounting block on the cover plate. Place fi xture onto the mounting block, being sure the wires 
are not being pinched. 
8.   Tighten the locking hex head bolt inside the arm with a 9/16" socket to 20-30 ft. lbs. torque (overtightening will cause stripping and void 
all warranties).    (See Figure 4)
9.   Close the doorframe and tighten the (2) captive doorframe screws.
10.   Make wire connections, observing proper voltage and polarity. Connect green ground wire from the fi xture to the fi eld ground wire.   
Reference wiring diagram on driver. 
11.   Attach small eyelet of safety cable to base plate with provided 1/4-20 screw (see diagram above).
12.   Slide the entire fi xture assembly over the base plate, tighten the top (2) 3/8" x 1-1/4" stainless steel hex head screws until 3/8" to 1/4" of 
the screw is still visible.  Tighten the two bottom hex head screws until 3/8" to 1/4" of the screw is still visible.  Alternating between the top 
two and bottom two sets of screws, gently tighten until snug, (approx one thread showing on each screw).

 

 

 

 

 

Lithonia Lighting Outdoor   •  One Lithonia Way  •  Conyers, Georgia 30012

Phone: 800-279-8041  •  Fax: 770.918.1209  •  

www.lithonia.com

© 2011 Acuity Brands Lighting, Inc.  All rights reserved.  Mar/13 

Cover plate

3/8" screw

Safety chain

Step 1

Silicone sealant  

(by others)

Step 2

(4) 1/4" fasteners 

(by others)

To wall

Gasket 

(factory installed)

Base plate

Attach to lower 

bolt with nut

Step 4

Step 11 

Threaded 

Steel Bar

Step 5

Hex head 

screws

Cover 

plate

Step 3

Fixture's mounting block (See fi gure 1)

Содержание DSX0

Страница 1: ...laced Recycle For information on how to recycle LED electronic products please visit www epa gov These instructions do not purport to cover all details or variations in equipment nor to provide every possible contingency to meet in connection with installation operation or maintenance Should further information be desired or should particular problems arise which are not covered sufficiently for t...

Страница 2: ...se ESD shorten lamp life or alter performance Some components inside the fixture may not be serviceable In the unlikely event your unit may require service stop using the unit immediately and contact an ABL representa ve for assistance Always read the fixtures complete installa on instruc ons prior to installa on for any addi onal fixture specific warnings CAUTION RISK OF PRODUCT DAMAGE Please see...

Страница 3: ...n the block making certain the wires are not pinched For ease of installation the mounting block will hold the weight of the luminaire prior to tightening the mounting bolt See Figure 2 3 To secure the fixture open doorframe by loosening the 2 captive screws using 3 16 allen wrench See Figure 3 4 Tighten the locking hex head bolt inside the arm with a 9 16 socket to 20 30 ft lbs torque overtighten...

Страница 4: ...ert and tighten 4 3 8 diameter by 1 1 4 stainless steel hex head screws into the threaded opening of the cover plate by turning approximately 6 7 full turns see diagram above 6 To prepare fixture for installation open doorframe by loosening the 2 captive screws using 3 16 allen wrench See Figure 3 7 Pull the wires from the fixture through the mounting block on the cover plate Place fixture onto th...

Отзывы: