3. Installation Preparation.
To prevent personal injury and damage ensure
that the hanging location allows the blades a
clearance of 84" (213 cm) from the floor and 30"
(76 cm) from any wall or obstruction.
This fan is suitable for room sizes up to 400
square feet (37.2 square meters).
This fan can be mounted with a
downrod
on a normal or vaulted ceiling. The hanging
length can be extended by purchasing a longer
downrod (.5 in./12.7mm diameter).
Continue to
Step 5 on page 4 after Hanging Bracket Installation.
Fan can also mount as a
flushmount
installation
on a normal ceiling only.
Continue to Step 6 on
page 5 after Hanging Bracket Installation.
Installation requires these tools:
Phillips screwdriver, flat-head screwdriver,
adjustable pliers or wrench, stepladder, wire
cutters, and rated electrical tape.
4. Hanging Bracket Installation.
Turn off circuit breakers to current fixture from
breaker panel and be sure operating light switch
is turned to the off position.
WARNING:
Failure to disconnect power supply
prior to installation may result in serious injury.
Remove existing fixture.
WARNING:
When using an existing outlet box be
sure the box is securely attached to the building
structure and can support the full weight of the fan.
Ensure it is clearly marked "Suitable for Fan
Support." If not, it must be replaced with an
approved one. Failure to do so can result in serious
injury.
Install hanging bracket to outlet box using
original screws and spring washers provided
with new or original outlet box. If installing on a
vaulted ceiling, face opening of hanging bracket
towards high point of ceiling. Arrange electrical
wiring around the back of the hanging bracket
and away from the bracket opening.
page 3
ON
OFF
ON
OFF
hanging bracket
rubber cushions
Vaulted ceiling
angle is not to
exceed 29 degrees.
downrod
installation
flushmount
installation
12 f
t.
- 20 f
t.
12 ft. - 20 ft.
(3.66 m - 6.1 m)
(3.66 m - 6.1 m)
blade edge
84
inches
(213 cm)
(76 cm)
30
inches
outlet box screws
spring washers