3. Installation Preparation.

page 3

ON

OFF

ON

OFF

To prevent personal injury and damage, 
ensure that the hanging location allows the 
blades a clearance of 7ft. (2.13m) from the 
floor and 30in. (76cm) from any wall or 
obstruction. 
This fan is suitable for room sizes up to 400  
square feet (37.2 square meters).

This fan can be mounted with a 

downrod

on a normal or vaulted ceiling. The hanging 
length can be extended by purchasing a 
longer downrod (0.5in./1.27cm diameter). 
Other installation, such as 

flushmount

, is 

not

 

available for this fan.

Installation requires these tools: 

Phillips screwdriver, flathead screwdriver, 
adjustable pliers or wrench, stepladder, wire 
cutters, and rated electrical tape.

Vaulted ceiling 
angle is not to 
exceed 25 degrees.  

downrod

installation

flushmount

installation

12f

t.

  - 20f

t.

12ft. - 20ft.

(3.66m - 6.1m)

(3.66m - 6.1m)

7 feet

(2.13m)

(76cm)

30 

inches

4. Hanging Bracket Installation.

Turn off circuit breakers to current fixture from 
breaker panel and be sure operating light switch is 
turned to the OFF position. 

WARNING: 

Failure to disconnect power supply prior 

to installation may result in serious injury.

Remove existing fixture. 

WARNING:

 When using an existing outlet box, be 

sure the box is securely attached to the building 
structure and can support the full weight of the fan. 
Ensure it is clearly marked "Suitable for Fan Support." 
If not, it must be replaced with an approved outlet 
box. Failure to do so can result in serious injury.

Install hanging bracket to outlet box using original 
screws, spring washers and flat washers (size 8 or 
M5) provided with new or original outlet box.

If 

installing on a vaulted ceiling, face opening of 
hanging bracket towards high point of ceiling. 
Arrange electrical wiring around the back of the 
hanging bracket and away from the bracket 
opening.

*Note

: It is very important that you use the proper hardware when installing the hanging bracket as this will 

support the fan. Please make certain that you purchase any hardware that is missing in order to install the 
hanging bracket properly.

 blade edge

hanging bracket

spring washers

outlet box screws

flat washers

Содержание PZ52ABZ5C

Страница 1: ...nstallation pg 3 Fan Assembly pgs 4 5 Wiring pg 5 Canopy Assembly pg 6 Blade Assembly pg 6 Light Kit Assembly Optional pgs 7 8 Testing Your Fan pg 8 Troubleshooting pg 9 Parts Replacement pg 9 Warranty pg 9 net weight of fan 26 46 lb 12 kg E192641 READ THESE INSTRUCTIONS AND SAVE THEM FOR FUTURE USE PRINTED IN CHINA For Models PZ52ABZ5C PZ52BNK5C ...

Страница 2: ...wire and two lead wires from the fan If your house wire is larger than 12 gauge or there is more than one house wire to connect to the two fan lead wires consult an electrician for the proper size wire connectors to use 5 Electrical diagrams are for reference only Light kits that are not packed with the fan must be UL listed and marked suitable for use with the model fan you are installing Switche...

Страница 3: ...l plate pre attached to light kit fitter 1 piece l finial pre attached to light kit fitter 1 piece m hardware packs page 2 g Carefully open the packaging Remove items from Styrofoam inserts Remove motor housing and place on carpet or Styrofoam to avoid damage to finish Do not discard fan carton or Styrofoam inserts should this fan need to be returned for repairs Check against parts inventory that ...

Страница 4: ...and be sure operating light switch is turned to the OFF position WARNING Failure to disconnect power supply prior to installation may result in serious injury Remove existing fixture WARNING When using an existing outlet box be sure the box is securely attached to the building structure and can support the full weight of the fan Ensure it is clearly marked Suitable for Fan Support If not it must b...

Страница 5: ... and raise hanging ball Be sure stop pin aligns with slots on the inside of the hanging ball Tighten set screw securely Slide downrod through canopy and yoke cover Thread electrical wires through downrod and pull extra wire slack from the upper end of the downrod Tip Apply small piece of electrical tape to the ends of the electrical wires to keep them together when threading them through the downr...

Страница 6: ...ical connections comply with Local Codes or Ordinances and the National Electrical Code If you are unfamiliar with electrical wiring or if the house building wires are different colors than those referred to below please use a qualified electrician When fan is secured in place on the hanging bracket electrical wiring can be made diagram 1 as follows Connect BLACK and BLUE wire from fan to BLACK wi...

Страница 7: ...side Then if applicable remove plastic motor locks and discard Align blade arm holes with motor screw holes and attach blade arm with lock washers and blade arm screws Before securing screws permanently repeat this procedure with remaining blade arms Secure all screws blade arm screws lock washers motor housing blade arm blade blade attachment screws and washers canopy hanging bracket screw If nec...

Страница 8: ... touching Remove finial finial plate and threaded washer from threaded rod at bottom of light kit fitter Raise glass shade in order to guide pull chains through corresponding holes at the bottom of the glass shade Align threaded rod with hole in middle of glass shade and push up gently until threaded rod comes through hole Be sure pull chain for fan operation does not rub against bulbs during oper...

Страница 9: ...pending on the season Attach pull chain extension s supplied to pull chain s or use custom pull chain extension s sold separately 9 Light Kit Assembly Optional cont If you wish to use fan WITHOUT the light kit remove hex nut and lock washer from threaded rod at top of light kit fitter Remove switch housing cap Locate small plastic cap in hardware pack and insert firmly into hole in middle of switc...

Страница 10: ...TD will replace or repair any fan which has faulty performance due to a defect in material or workmanship Contact Litex Customer Service at 1 800 527 1292 to arrange for return of fan Return fan shipping prepaid to Litex Industries Ltd We will repair or ship you a replacement fan and we will pay the return shipping cost 5 YEAR WARRANTY LITEX INDUSTRIES LTD will repair or replace at no charge to th...