LITE-CHECK VERIFIER TRAILER INSPECTION SYSTEM
Saving Reports
To generate a PDF version of a report, open it and click ”Print” in the web browser menu. When the
print dialog appears change the destination to ”Save as PDF” then click save. You can also send the
report to a printer. PDF versions are ideal for saving on the local computer or sending via e-mail.
Troubleshooting - Trailer Interface and Tablet
If the tablet loses its link to the VERIFIER Trailer Interface (becomes unresponsive):
1. Try moving the tablet closer to the tester. Press the Bluetooth icon in the upper–left corner of the
screen and select the Verifier from the list. If you do not see it in the list see
Appendix A
.
2. Restart the app
A. Press the ”
APP HISTORY
” icon (to one side of the Home button; looks like two boxes, one
in front of the other)
B. Swipe the title bar of the DOT app off the screen
C. Return to Home screen
D. Press the ”LITE-CHECK DOT” icon on the Home screen to restart
E. If these steps do not resolve the problem, move on to step #3
3. Reset the VERIFIER Trailer Interface(TI) and restart the LITE-CHECK DOT app Press the
”
RESET
” button on the front panel of the tester If these steps do not resolve the problem, move
on to step #4
4. Cycle power on both the VERIFIER Trailer Interface and Tablet
For the VERIFIER TI:
(a) Press the ”
POWER
” button on the front panel (
Note that Emergency and Service air, if
active, will be released!
)
(b) Wait for the
RED LED
(Fault) to turn OFF
(c) Press the ”
POWER
” button again to turn the VERIFIER Trailer Interface back on
For the Tablet:
(a) Press and hold the ”
POWER
” button
(b) Select ”
Power OFF
”
(c) Select ”
Power OFF
” again
(d) Wait for the ”
BLANK
” screen
(e) To turn the tablet back on, press and hold the ”
POWER
” button until graphics appear on the
screen
(f) Wait for the tablet to finish booting
(g) Swipe the LOCK icon
(h) Restart the LITE-CHECK DOT app
17